---
title: "Milgard Manufacturing 8520T2.8530T2.8570T2 Casement Specs"
url: https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8520t2-8530t2-8570t2-casement-413771/
description: "Milgard Manufacturing 8520T2.8530T2.8570T2 Casement (MIL-A-309, Casement Windows, Vinyl): U-Factor 0.15-0.32, SHGC 0.08-0.46, 24195 options across 4 ENERGY."
---

Window · Vinyl Frame NFRC MIL · Product Line MIL-A-309 ENERGY STAR Most Efficient Eligible

# Milgard Manufacturing, Inc. — 8520T2.8530T2.8570T2 Casement · Casement Windows

Milgard Manufacturing, Inc. engineered the 8520T2.8530T2.8570T2 Casement Casement Windows line for Northern, North-Central, South-Central, Southern, certifying 24,195 glass-spacer combinations from 0.15 to 0.32 U-Factor and 0.08 to 0.46 SHGC. Relative to other Vinyl models tracked under NFRC MIL, its minimum U-Factor is 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.15

- **SHGC Range** : 0.08-0.46

- **Certified Options** : 24,195

- **Category Standing** : #136 of 1,352

## How does Milgard Manufacturing, Inc. 8520T2.8530T2.8570T2 Casement compare thermally against Window peers?

Milgard Manufacturing, Inc. 8520T2.8530T2.8570T2 Casement achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Milgard Manufacturing, Inc. 8520T2.8530T2.8570T2 Casement standing at #136 of 1,352 certified Window product series, tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%. Comparing Vinyl profiles alone (median 0.19) shows -0.04 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. 1,768 configurations meet ENERGY STAR Most Efficient criteria while 2,801 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors MIL to 2025-01-30 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 90.0 BTU/hr conductive loss (-31.8% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 24,195 certified glazing combinations for 8520T2.8530T2.8570T2 Casement (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 2,801 packages (516 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 11,705 packages (931 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 16,691 packages (716 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 21,237 packages (1,553 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**PGT Industries** — PW5440/5540](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-pw5440-5540-413923/) | Vinyl | 0.15 | 0.07 | 25,346 |
| [**Simonton Building Products, Inc. - Simonton Windows** — 325-325 CA PW (No Hinge)](https://ela-ecolandscapingassn.org/windows/models/simonton-building-products-inc-simonton-windows-325-325-ca-pw-no-hin/) | Vinyl | 0.15 | 0.08 | 19,435 |
| [**Wincore Window Company, LLC** — 5400, 7700 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-5400-7700-casement-picture-window-414336/) | Vinyl | 0.15 | 0.07 | 16,031 |
| [**JELD-WEN, inc.** — Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-tilt-single-hung-fixed-direct-set/) | Vinyl | 0.15 | 0.13 | 13,014 |
| [**MI Windows and Doors, LLC** — 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-1650-polyvinyl-chloride-pvc-fixed-direct-se/) | Vinyl | 0.15 | 0.07 | 11,774 |

## What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [8521T2.8531T2.8571T2 Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8521t2-8531t2-8571t2-casement-fixed-413773/)

U-Factor 0.13–0.32 · 23,185 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8521t2-8531t2-8571t2-casement-fixed-413773/)

Picture WindowMin U 0.13

### [8541T2 Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8541t2-casement-fixed-413778/)

U-Factor 0.13–0.32 · 37,615 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8541t2-casement-fixed-413778/)

Picture WindowMin U 0.14

### [12710 Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12710-fixed-413789/)

U-Factor 0.14–0.32 · 3,568 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12710-fixed-413789/)

Picture WindowMin U 0.14

### [8320T2.8330T2 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8320t2-8330t2-picture-window-413774/)

U-Factor 0.14–0.32 · 22,562 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8320t2-8330t2-picture-window-413774/)

Picture WindowMin U 0.14

### [8340T2 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8340t2-picture-window-413775/)

U-Factor 0.14–0.32 · 35,182 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8340t2-picture-window-413775/)

Picture WindowMin U 0.15

### [12330 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12330-picture-window-413787/)

U-Factor 0.15–0.32 · 7,836 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12330-picture-window-413787/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 8520T2.8530T2.8570T2 Casement appear below.

### What U-Factor and SHGC range does Milgard Manufacturing, Inc. 8520T2.8530T2.8570T2 Casement achieve?

Across 24,195 tested NFRC glazing configurations, Milgard Manufacturing, Inc. 8520T2.8530T2.8570T2 Casement with Vinyl framing and Casement Single-Vent (CSSV) style reaches a 0.15 minimum U-Factor and 0.08-0.46 SHGC band. It places #136 among 1,352 Window series—top 18.4%.

### Can homeowners install 8520T2.8530T2.8570T2 Casement in cold Northern ENERGY STAR counties?

Yes. 2,801 packages in Milgard Manufacturing, Inc. 8520T2.8530T2.8570T2 Casement clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

### How much winter heat loss does 8520T2.8530T2.8570T2 Casement conduct across a 15 sq ft opening?

Using NFRC MIL U-Factor 0.15, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 90.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-42.0 BTU/hr margin).

### Which situations make 8520T2.8530T2.8570T2 Casement the wrong window or door choice?

Skip 8520T2.8530T2.8570T2 Casement if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 8520T2.8530T2.8570T2 Casement options exceeding U 0.22.

### Can you install Milgard Manufacturing, Inc. 8520T2.8530T2.8570T2 Casement in Southern or South-Central zones?

Exactly 21,237 8520T2.8530T2.8570T2 Casement options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.08 rather than higher 0.46 glass.

### How many Milgard Manufacturing, Inc. 8520T2.8530T2.8570T2 Casement variants earn ENERGY STAR Most Efficient?

EPA lists 1,768 Most Efficient options (7.3% share) inside Milgard Manufacturing, Inc. 8520T2.8530T2.8570T2 Casement, out of 24,195 total Version 7.0 entries.

### What federal compliance checks govern 2026 8520T2.8530T2.8570T2 Casement window swaps?

Any 8520T2.8530T2.8570T2 Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How can homeowners confirm delivered Milgard Manufacturing, Inc. 8520T2.8530T2.8570T2 Casement units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MIL and product line MIL-A-309, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 8520T2.8530T2.8570T2 Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
