---
title: "Morfe Windows Fixed Window Specs (U 0.21) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/morfe-windows-llc-fixed-window-413792/
description: "Morfe Windows Fixed Window (MRF-A-3, Picture Window, Vinyl): U-Factor 0.21-0.29, SHGC 0.20-0.23, 20 options across 4 ENERGY STAR zones. Verified against."
---

Window · Vinyl Frame NFRC MRF · Product Line MRF-A-3 ENERGY STAR Most Efficient Eligible

# Morfe Windows LLC — Fixed Window · Picture Window

Across 3 Morfe Windows LLC certified families, Fixed Window supplies 20 Picture Window configurations starting at 0.21 U-Factor and 0.20 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.29 U-Factor and 0.23 SHGC. Its thermal floor ranks #742 of 1,352 category entries—0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.21

- **SHGC Range** : 0.20-0.23

- **Certified Options** : 20

- **Category Standing** : #742 of 1,352

## How does Morfe Windows LLC Fixed Window compare thermally against Window peers?

Morfe Windows LLC Fixed Window achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Fixed Window spans 20 NFRC test records (MRF), ranking #742 of 1,352 Window families (tied with 88 others at 0.21, more insulating than 38.6% of Window lines). Its 0.21 thermal floor compares at +0.02 against the Vinyl median (0.19).

Climate coverage for Morfe Windows LLC Fixed Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 2 configurations meet ENERGY STAR Most Efficient criteria while 3 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 126.0 BTU/hr (-4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2020-08-27 and cert timestamp 2025-09-09.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 20 certified glazing combinations for Fixed Window (NFRC MRF) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 3 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 8 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 19 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 20 packages (2 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**California Deluxe Windows Industries, Inc.** — S-3200 Fixed](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3200-fixed-413099/) | Vinyl | 0.21 | 0.14 | 24 |
| [**Target Windows and Doors** — 4000 Double Hung](https://ela-ecolandscapingassn.org/windows/models/target-windows-and-doors-4000-double-hung-414139/) | Vinyl | 0.21 | 0.17 | 24 |
| [**Kohltech International, Ltd.** — Supreme Single Hung](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-supreme-single-hung-413494/) | Vinyl | 0.21 | 0.21 | 15 |
| [**REHAU, S.A. DE C.V.** — S190 Fixed Window](https://ela-ecolandscapingassn.org/windows/models/rehau-s-a-de-c-v-s190-fixed-window-414011/) | Vinyl | 0.21 | 0.15 | 15 |
| [**Target Windows and Doors** — SL 3150 Fixed Window](https://ela-ecolandscapingassn.org/windows/models/target-windows-and-doors-sl-3150-fixed-window-414141/) | Vinyl | 0.21 | 0.22 | 15 |

## What other certified series does Morfe Windows LLC produce?

Compare other active Morfe Windows LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Double SliderMin U 0.23

### [Horizontal Sliding Window](https://ela-ecolandscapingassn.org/windows/models/morfe-windows-llc-horizontal-sliding-window-413791/)

U-Factor 0.23–0.30 · 20 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/morfe-windows-llc-horizontal-sliding-window-413791/)

Double HungMin U 0.24

### [Double Hung Window](https://ela-ecolandscapingassn.org/windows/models/morfe-windows-llc-double-hung-window-413790/)

U-Factor 0.24–0.30 · 36 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/morfe-windows-llc-double-hung-window-413790/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Morfe Windows LLC Fixed Window appear below.

### How efficient is Morfe Windows LLC Fixed Window compared with peer Window models?

Testing puts Morfe Windows LLC Fixed Window at rank #742 of 1,352 Window entries with U 0.21 to 0.29 across 20 configurations. Solar heat gain ranges between 0.20 and 0.23 across Northern, North-Central, South-Central, Southern.

### How does Morfe Windows LLC Fixed Window satisfy Version 7.0 Northern criteria?

Cold-climate buyers get 3 compliant Northern packages inside Fixed Window, reaching down to U 0.21. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.29 options.

### How do you calculate winter heat conduction for Morfe Windows LLC Fixed Window?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.21 U-Factor yields 126.0 BTU/hr conductive transfer (-4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What homeowner profiles are a poor match for Morfe Windows LLC Fixed Window?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Fixed Window options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### Is Fixed Window suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 20 Southern-approved options within Fixed Window spanning SHGC down to 0.20. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### Does Fixed Window carry EPA Most Efficient certification across its lineup?

EPA lists 2 Most Efficient options (10.0% share) inside Morfe Windows LLC Fixed Window, out of 20 total Version 7.0 entries.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Fixed Window?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Fixed Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### Where are NFRC and IGCC identification marks located on Fixed Window?

Confirm both the paper NFRC label and permanent corner glass etch match line MRF-A-3 and NFRC ID MRF before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Morfe Windows LLC Fixed Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
