---
title: "National Vinyl TG/NW3/Destiny/DuraTrust/Clarion Picture"
url: https://ela-ecolandscapingassn.org/windows/models/national-vinyl-llc-tg-nw3-destiny-duratrust-clarion-picture-window-4/
description: "National Vinyl TG/NW3/Destiny/DuraTrust/Clarion Picture Window (NVP-K-31, Picture Window, Vinyl): U-Factor 0.13-0.26, SHGC 0.25-0.57, 52 options across 2."
---

Window · Vinyl Frame NFRC NVP · Product Line NVP-K-31 ENERGY STAR Most Efficient Eligible

# National Vinyl, LLC — TG/NW3/Destiny/DuraTrust/Clarion Picture Window · Picture Window

Positioning #36/1,352 in certified Window, National Vinyl, LLC TG/NW3/Destiny/DuraTrust/Clarion Picture Window pairs Vinyl frame construction with 52 glazing options rated between 0.25 and 0.57 SHGC across Northern, North-Central. Across 6 certified National Vinyl, LLC product families, its thermal resistance spans 0.13 to 0.26 U-Factor and the line includes 19 ENERGY STAR Most Efficient packages (36.5% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.13

- **SHGC Range** : 0.25-0.57

- **Certified Options** : 52

- **Category Standing** : #36 of 1,352

## How does National Vinyl, LLC TG/NW3/Destiny/DuraTrust/Clarion Picture Window compare thermally against Window peers?

National Vinyl, LLC TG/NW3/Destiny/DuraTrust/Clarion Picture Window achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places National Vinyl, LLC TG/NW3/Destiny/DuraTrust/Clarion Picture Window at rank #36 of 1,352 (tied with 35 others at 0.13, more insulating than 94.7% of Window lines, top 5.3%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.25-0.57 band.

Zone eligibility across EPA boundaries reaches 2 markets (Northern, North-Central). 19 configurations meet ENERGY STAR Most Efficient criteria while 43 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2026-03-02 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 78.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 52 certified glazing combinations for TG/NW3/Destiny/DuraTrust/Clarion Picture Window (NFRC NVP) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 43 packages (19 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 35 packages (19 Most Eff.) |
| **South-Central** | Not Listed | <= 0.28 | <= 0.23 | 0 packages (0 Most Eff.) |
| **Southern** | Not Listed | <= 0.32 | <= 0.23 | 0 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**OKNA Windows & Doors Mfg** — 7580 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7580-casement-picture-window-413876/) | Vinyl | 0.13 | 0.17 | 73 |
| [**Vytex Corporation** — 3300 Fixed](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-fixed-414300/) | Vinyl | 0.13 | 0.15 | 78 |
| [**Slocomb Windows and Doors, Inc** — 100 Series Picture Window](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-100-series-picture-window-414102/) | Vinyl | 0.13 | 0.15 | 158 |
| [**North Star Manufacturing (London) Ltd.** — 1071 Fixed](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1071-fixed-413828/) | Vinyl | 0.13 | 0.17 | 205 |
| [**Advanced Window Corp.** — EU 76 Septem Fixed](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-fixed-412865/) | Vinyl | 0.13 | 0.15 | 300 |

## What other certified series does National Vinyl, LLC produce?

Compare other active National Vinyl, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [TG/NW3/Destiny/Sentinel Deadlite](https://ela-ecolandscapingassn.org/windows/models/national-vinyl-llc-tg-nw3-destiny-sentinel-deadlite-413855/)

U-Factor 0.14–0.26 · 49 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/national-vinyl-llc-tg-nw3-destiny-sentinel-deadlite-413855/)

Double SliderMin U 0.17

### [TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/national-vinyl-llc-tg-nw3-destiny-duratrust-clarion-northwind-br-hor/)

U-Factor 0.17–0.26 · 51 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/national-vinyl-llc-tg-nw3-destiny-duratrust-clarion-northwind-br-hor/)

Awning (Projected)Min U 0.18

### [TG/NW3/Destiny/Duratrust/Clarion/Sentinel Awning](https://ela-ecolandscapingassn.org/windows/models/national-vinyl-llc-tg-nw3-destiny-duratrust-clarion-sentinel-awning/)

U-Factor 0.18–0.30 · 73 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/national-vinyl-llc-tg-nw3-destiny-duratrust-clarion-sentinel-awning/)

Casement WindowsMin U 0.18

### [TG/NW3/Destiny/Duratrust/Clarion/Sentinel Casement](https://ela-ecolandscapingassn.org/windows/models/national-vinyl-llc-tg-nw3-destiny-duratrust-clarion-sentinel-casemen/)

U-Factor 0.18–0.30 · 75 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/national-vinyl-llc-tg-nw3-destiny-duratrust-clarion-sentinel-casemen/)

Sliding Patio DoorMin U 0.19

### [EnduraView Sliding Patio Door](https://ela-ecolandscapingassn.org/windows/models/national-vinyl-llc-enduraview-sliding-patio-door-413856/)

U-Factor 0.19–0.25 · 4 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/national-vinyl-llc-enduraview-sliding-patio-door-413856/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to National Vinyl, LLC TG/NW3/Destiny/DuraTrust/Clarion Picture Window appear below.

### How efficient is National Vinyl, LLC TG/NW3/Destiny/DuraTrust/Clarion Picture Window compared with peer Window models?

Across 52 tested NFRC glazing configurations, National Vinyl, LLC TG/NW3/Destiny/DuraTrust/Clarion Picture Window with Vinyl framing and Fixed Window (FIXD) style reaches a 0.13 minimum U-Factor and 0.25-0.57 SHGC band. It places #36 among 1,352 Window series—top 5.3%.

### How does National Vinyl, LLC TG/NW3/Destiny/DuraTrust/Clarion Picture Window satisfy Version 7.0 Northern criteria?

National Vinyl, LLC TG/NW3/Destiny/DuraTrust/Clarion Picture Window supplies 43 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.26, so inspect the NFRC order sheet before purchase.

### What conductive BTU/hr difference separates TG/NW3/Destiny/DuraTrust/Clarion Picture Window from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), TG/NW3/Destiny/DuraTrust/Clarion Picture Window at U 0.13 conducts 78.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### Which situations make TG/NW3/Destiny/DuraTrust/Clarion Picture Window the wrong window or door choice?

Skip TG/NW3/Destiny/DuraTrust/Clarion Picture Window if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on TG/NW3/Destiny/DuraTrust/Clarion Picture Window options exceeding U 0.22.

### What Southern ENERGY STAR v7.0 options exist in TG/NW3/Destiny/DuraTrust/Clarion Picture Window?

National Vinyl, LLC TG/NW3/Destiny/DuraTrust/Clarion Picture Window carries zero Southern Zone approvals (0 options; SHGC 0.25-0.57). Cooling-dominated sunbelt homes should look at peer lines certified to SHGC <= 0.23.

### How many National Vinyl, LLC TG/NW3/Destiny/DuraTrust/Clarion Picture Window variants earn ENERGY STAR Most Efficient?

No. Exactly 19 of 52 configurations (36.5%) earn ENERGY STAR Most Efficient status in TG/NW3/Destiny/DuraTrust/Clarion Picture Window; the remaining standard v7.0 options pass base zone limits only.

### Do 2026 TG/NW3/Destiny/DuraTrust/Clarion Picture Window installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 National Vinyl, LLC upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How do you cross-check NFRC NVP and product line NVP-K-31 on delivery?

Inspectors match the temporary NFRC sticker (U 0.13-0.26, SHGC 0.25-0.57) against permit drawings for line NVP-K-31. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for National Vinyl, LLC TG/NW3/Destiny/DuraTrust/Clarion Picture Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
