title: "North Star Manufacturing (London) 1273 Double Slider"
url: https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1273-double-slider-lift-out-4138/
description: "North Star Manufacturing (London) 1273 Double Slider Lift-Out (NSM-A-19, Double Slider, Vinyl): U-Factor 0.20-0.28, SHGC 0.16-0.51, 71 options across 4."
---

Window · Vinyl Frame NFRC NSM · Product Line NSM-A-19 ENERGY STAR Most Efficient Eligible

# North Star Manufacturing (London) Ltd. — 1273 Double Slider Lift-Out · Double Slider

Positioning #671/1,352 in certified Window, North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out pairs Vinyl frame construction with 71 glazing options rated between 0.16 and 0.51 SHGC across Northern, North-Central, South-Central, Southern. Across 11 certified North Star Manufacturing (London) Ltd. product families, its thermal resistance spans 0.20 to 0.28 U-Factor and the line includes 5 ENERGY STAR Most Efficient packages (7.0% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.20

- **SHGC Range** : 0.16-0.51

- **Certified Options** : 71

- **Category Standing** : #671 of 1,352

## How does North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out compare thermally against Window peers?

North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 1273 Double Slider Lift-Out spans 71 NFRC test records (NSM), ranking #671 of 1,352 Window families (tied with 70 others at 0.20, more insulating than 45.2% of Window lines). Its 0.20 thermal floor compares at +0.01 against the Vinyl median (0.19).

Climate coverage for North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 5 configurations meet ENERGY STAR Most Efficient criteria while 24 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 120.0 BTU/hr (-9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-12-05.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 71 certified glazing combinations for 1273 Double Slider Lift-Out (NFRC NSM) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 24 packages (0 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 28 packages (1 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 40 packages (1 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 40 packages (5 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**United Window & Door Mfg., Inc.** — 9600 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/united-window-door-mfg-inc-9600-horizontal-slider-414214/) | Vinyl | 0.20 | 0.13 | 66 |
| [**Soft-Lite, LLC** — Elements DSL20 Slider](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-elements-dsl20-slider-414105/) | Vinyl | 0.20 | 0.17 | 60 |
| [**Soft-Lite, LLC** — Imperial Elite DSL12E](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-imperial-elite-dsl12e-414116/) | Vinyl | 0.20 | 0.17 | 60 |
| [**Walsh Building Products** — 6100 Double Slider](https://ela-ecolandscapingassn.org/windows/models/walsh-building-products-6100-double-slider-414307/) | Vinyl | 0.20 | 0.18 | 59 |
| [**Thompson Creek Window Company** — 7900 Double Hung](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7900-double-hung-414149/) | Vinyl | 0.20 | 0.17 | 88 |

## What other certified series does North Star Manufacturing (London) Ltd. produce?

Compare other active North Star Manufacturing (London) Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [1071 Fixed](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1071-fixed-413828/)

U-Factor 0.13–0.26 · 205 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1071-fixed-413828/)

Picture WindowMin U 0.15

### [1072 Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1072-fixed-casement-413831/)

U-Factor 0.15–0.26 · 200 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1072-fixed-casement-413831/)

Sliding Patio DoorMin U 0.15

### [Comfort Patio Door](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-comfort-patio-door-413838/)

U-Factor 0.15–0.27 · 194 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-comfort-patio-door-413838/)

Casement WindowsMin U 0.16

### [1171 Casement](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1171-casement-413829/)

U-Factor 0.16–0.26 · 293 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1171-casement-413829/)

Awning (Projected)Min U 0.16

### [1173 Awning](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1173-awning-413830/)

U-Factor 0.16–0.27 · 291 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1173-awning-413830/)

Picture WindowMin U 0.19

### [1377 Fixed Single Hung](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1377-fixed-single-hung-413837/)

U-Factor 0.19–0.27 · 19 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1377-fixed-single-hung-413837/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out appear below.

### What U-Factor and SHGC range does North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out achieve?

Testing puts North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out at rank #671 of 1,352 Window entries with U 0.20 to 0.28 across 71 configurations. Solar heat gain ranges between 0.16 and 0.51 across Northern, North-Central, South-Central, Southern.

### Can homeowners install 1273 Double Slider Lift-Out in cold Northern ENERGY STAR counties?

Yes. 24 packages in North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.28.

### How does a 3x5 ft 1273 Double Slider Lift-Out window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.20 U-Factor yields 120.0 BTU/hr conductive transfer (-9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### Who should NOT choose North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1273 Double Slider Lift-Out options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Is 1273 Double Slider Lift-Out suitable for sunbelt cooling-dominated homes?

Yes, 1273 Double Slider Lift-Out holds 40 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.16 SHGC in cooling climates.

### Does 1273 Double Slider Lift-Out carry EPA Most Efficient certification across its lineup?

Only 5 options out of 71 (7.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out, usually requiring triple-pane or upgraded Low-E coatings.

### What 2026 federal tax credit and Lead RRP rules apply to 1273 Double Slider Lift-Out?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 1273 Double Slider Lift-Out retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### What permanent glass etch marks verify 1273 Double Slider Lift-Out after sticker removal?

Verify NFRC ID NSM and series NSM-A-19 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for North Star Manufacturing (London) Ltd. 1273 Double Slider Lift-Out come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)