---
title: "North Star Manufacturing (London) Comfort Patio Door Specs"
url: https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-comfort-patio-door-413838/
description: "North Star Manufacturing (London) Comfort Patio Door (NSM-A-30, Sliding Patio Door, Vinyl): U-Factor 0.15-0.27, SHGC 0.14-0.40, 194 options across 4 ENERGY."
---

Door · Vinyl Frame NFRC NSM · Product Line NSM-A-30 ENERGY STAR Most Efficient Eligible

# North Star Manufacturing (London) Ltd. — Comfort Patio Door · Sliding Patio Door

EPA ENERGY STAR Version 7.0 certifies 194 variants inside North Star Manufacturing (London) Ltd. Comfort Patio Door, combining Vinyl frame construction with U-Factors spanning 0.15 to 0.27 and SHGC 0.14 to 0.40. Qualifying for Northern, North-Central, South-Central, Southern, this Sliding Patio Door family places #18 of 268 among 268 Door families and posts 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.15

- **SHGC Range** : 0.14-0.40

- **Certified Options** : 194

- **Category Standing** : #18 of 268

## How does North Star Manufacturing (London) Ltd. Comfort Patio Door compare thermally against Door peers?

North Star Manufacturing (London) Ltd. Comfort Patio Door achieves a 0.15 thermal floor across Door lines, placing #18 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), Comfort Patio Door is 0.06 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.15-0.27.

Climate coverage for North Star Manufacturing (London) Ltd. Comfort Patio Door spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 110 configurations meet ENERGY STAR Most Efficient criteria while 181 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.15 U-Factor yields 90.0 BTU/hr transfer (-42.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-10-23 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 194 certified glazing combinations for Comfort Patio Door (NFRC NSM) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 181 packages (47 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 181 packages (97 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 106 packages (54 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 106 packages (67 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Advanced Window Corp.** — EU 76 Septem Balcony Door](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-balcony-door-412868/) | Vinyl | 0.15 | 0.12 | 360 |
| [**DRUTEX S.A.** — IGLO ENERGY Tilt and Slide Door](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-tilt-and-slide-door-413161/) | Vinyl | 0.15 | 0.13 | 2,993 |
| [**Associated Materials, Inc.** — A172/A173/A175 Sliding Patio Door](https://ela-ecolandscapingassn.org/windows/models/associated-materials-inc-a172-a173-a175-sliding-patio-door-413053/) | Vinyl | 0.15 | 0.07 | 9,221 |
| [**Therma-Tru Corporation** — Fiberglass Entry Door](https://ela-ecolandscapingassn.org/windows/models/therma-tru-corporation-fiberglass-entry-door-414156/) | Wood | 0.15 | 0.01 | 1,382 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra-VistaLuxe-Forgent Complimentary Gardenaire Sliding Patio Door](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-vistaluxe-forgent-complimentar/) | Other / Wood | 0.15 | 0.08 | 6,598 |

## What other certified series does North Star Manufacturing (London) Ltd. produce?

Compare other active North Star Manufacturing (London) Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [1071 Fixed](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1071-fixed-413828/)

U-Factor 0.13–0.26 · 205 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1071-fixed-413828/)

Picture WindowMin U 0.15

### [1072 Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1072-fixed-casement-413831/)

U-Factor 0.15–0.26 · 200 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1072-fixed-casement-413831/)

Casement WindowsMin U 0.16

### [1171 Casement](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1171-casement-413829/)

U-Factor 0.16–0.26 · 293 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1171-casement-413829/)

Awning (Projected)Min U 0.16

### [1173 Awning](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1173-awning-413830/)

U-Factor 0.16–0.27 · 291 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1173-awning-413830/)

Picture WindowMin U 0.19

### [1377 Fixed Single Hung](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1377-fixed-single-hung-413837/)

U-Factor 0.19–0.27 · 19 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1377-fixed-single-hung-413837/)

Double HungMin U 0.20

### [1271 Double Hung](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1271-double-hung-413835/)

U-Factor 0.20–0.28 · 73 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1271-double-hung-413835/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to North Star Manufacturing (London) Ltd. Comfort Patio Door appear below.

### What U-Factor and SHGC range does North Star Manufacturing (London) Ltd. Comfort Patio Door achieve?

Built with Vinyl framing in Sliding Glass Door (DDSG) style, North Star Manufacturing (London) Ltd. Comfort Patio Door offers 194 Version 7.0 configurations from U 0.15 up to 0.27, posting -0.06 against the Door median of 0.21 with 110 Most Efficient picks.

### How does North Star Manufacturing (London) Ltd. Comfort Patio Door satisfy Version 7.0 Northern criteria?

Prescriptive Northern compliance covers 181 Comfort Patio Door packages (U floor 0.15, SHGC >= 0.17). Because the complete series stretches up to U 0.27, specify the cold-climate glass code explicitly.

### What BTU/hr heat transfer results from Comfort Patio Door's 0.15 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.15 U-Factor yields 90.0 BTU/hr conductive transfer (-31.8% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What homeowner profiles are a poor match for North Star Manufacturing (London) Ltd. Comfort Patio Door?

Skip Comfort Patio Door if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Comfort Patio Door options exceeding U 0.22.

### Does Comfort Patio Door meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, Comfort Patio Door holds 106 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.14 SHGC in cooling climates.

### How many North Star Manufacturing (London) Ltd. Comfort Patio Door variants earn ENERGY STAR Most Efficient?

Only 110 options out of 194 (56.7%) meet tighter Most Efficient U-Factor and SHGC thresholds in North Star Manufacturing (London) Ltd. Comfort Patio Door, usually requiring triple-pane or upgraded Low-E coatings.

### What federal compliance checks govern 2026 Comfort Patio Door window swaps?

Any Comfort Patio Door purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### What permanent glass etch marks verify Comfort Patio Door after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code NSM and product line NSM-A-30, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for North Star Manufacturing (London) Ltd. Comfort Patio Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
