---
title: "Northeast Windows USA AW390 Awning Specs (U 0.19)"
url: https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-aw390-awning-413813/
description: "Northeast Windows USA AW390 Awning (NEW-A-26, Awning (Projected), Vinyl): U-Factor 0.19-0.32, SHGC 0.08-0.46, 285 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC NEW · Product Line NEW-A-26 ENERGY STAR Most Efficient Eligible

# Northeast Windows USA, Inc. — AW390 Awning · Awning (Projected)

Positioning #564/1,352 in certified Window, Northeast Windows USA, Inc. AW390 Awning pairs Vinyl frame construction with 285 glazing options rated between 0.08 and 0.46 SHGC across Northern, North-Central, South-Central, Southern. Across 10 certified Northeast Windows USA, Inc. product families, its thermal resistance spans 0.19 to 0.32 U-Factor and the line includes 54 ENERGY STAR Most Efficient packages (18.9% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.19

- **SHGC Range** : 0.08-0.46

- **Certified Options** : 285

- **Category Standing** : #564 of 1,352

## How does Northeast Windows USA, Inc. AW390 Awning compare thermally against Window peers?

Northeast Windows USA, Inc. AW390 Awning achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Northeast Windows USA, Inc. AW390 Awning standing at #564 of 1,352 certified Window product series, tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%. Comparing Vinyl profiles alone (median 0.19) shows At median before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 54 configurations meet ENERGY STAR Most Efficient criteria while 122 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-10-03 and v7.0 data certification on 2024-11-17. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.19 conducts 114.0 BTU/hr (-18.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 285 certified glazing combinations for AW390 Awning (NFRC NEW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 122 packages (9 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 215 packages (12 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 184 packages (12 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 185 packages (54 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Value Windows & Doors** — Onyx Casement](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-onyx-casement-414287/) | Vinyl | 0.19 | 0.08 | 281 |
| [**Advanced Window Corp.** — 6300 Sliding Window](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-sliding-window-412857/) | Vinyl | 0.19 | 0.17 | 256 |
| [**Joyce Manufacturing Co.** — Insulator INCA Casement](https://ela-ecolandscapingassn.org/windows/models/joyce-manufacturing-co-insulator-inca-casement-413401/) | Vinyl | 0.19 | 0.14 | 243 |
| [**Specialty Wholesale Supply** — 7000/7500 TrustGard Casement](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-7000-7500-trustgard-casement-413547/) | Vinyl | 0.19 | 0.07 | 327 |
| [**Joyce Manufacturing Co.** — Insulator INAW Awning](https://ela-ecolandscapingassn.org/windows/models/joyce-manufacturing-co-insulator-inaw-awning-413406/) | Vinyl | 0.19 | 0.14 | 242 |

## What other certified series does Northeast Windows USA, Inc. produce?

Compare other active Northeast Windows USA, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Casement WindowsMin U 0.19

### [CW390 Casement](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-cw390-casement-413808/)

U-Factor 0.19–0.32 · 325 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-cw390-casement-413808/)

Picture WindowMin U 0.19

### [PW4015](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-pw4015-413810/)

U-Factor 0.19–0.32 · 295 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-pw4015-413810/)

Awning (Projected)Min U 0.21

### [AW300 Awning](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-aw300-awning-413812/)

U-Factor 0.21–0.29 · 240 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-aw300-awning-413812/)

Casement WindowsMin U 0.21

### [CW300 Casement](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-cw300-casement-413811/)

U-Factor 0.21–0.32 · 266 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-cw300-casement-413811/)

Picture WindowMin U 0.21

### [PW630](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-pw630-413807/)

U-Factor 0.21–0.31 · 133 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-pw630-413807/)

Double SliderMin U 0.21

### [SL4011 Slider](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-sl4011-slider-413809/)

U-Factor 0.21–0.31 · 212 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-sl4011-slider-413809/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Northeast Windows USA, Inc. AW390 Awning appear below.

### How efficient is Northeast Windows USA, Inc. AW390 Awning compared with peer Window models?

Across 285 tested NFRC glazing configurations, Northeast Windows USA, Inc. AW390 Awning with Vinyl framing and Projected Awning (PRAW) style reaches a 0.19 minimum U-Factor and 0.08-0.46 SHGC band. It places #564 among 1,352 Window series—top 49.6%.

### How does Northeast Windows USA, Inc. AW390 Awning satisfy Version 7.0 Northern criteria?

Yes. 122 packages in Northeast Windows USA, Inc. AW390 Awning clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

### How do you calculate winter heat conduction for Northeast Windows USA, Inc. AW390 Awning?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), AW390 Awning at U 0.19 conducts 114.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### What are the practical limitations of specifying AW390 Awning?

Do not specify AW390 Awning without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on AW390 Awning options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Is AW390 Awning suitable for sunbelt cooling-dominated homes?

Across Northern, North-Central, South-Central, Southern, 185 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Northeast Windows USA, Inc. AW390 Awning, while total line SHGC reaches 0.46 in colder packages.

### Does AW390 Awning carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 54 of 285 AW390 Awning glazing builds earn Most Efficient recognition (18.9%), while other variants sit on the standard Version 7.0 tier.

### Do 2026 AW390 Awning installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How do you cross-check NFRC NEW and product line NEW-A-26 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code NEW and product line NEW-A-26, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Northeast Windows USA, Inc. AW390 Awning come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
