---
title: "Northeast Windows USA SL610 Slider Specs (U 0.23)"
url: https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-sl610-slider-413806/
description: "Northeast Windows USA SL610 Slider (NEW-A-14, Single Slider, Vinyl): U-Factor 0.23-0.31, SHGC 0.19-0.53, 107 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC NEW · Product Line NEW-A-14

# Northeast Windows USA, Inc. — SL610 Slider · Single Slider

Northeast Windows USA, Inc. SL610 Slider is a Single Slider assembly with a Vinyl frame that reaches a minimum U-Factor of 0.23 across 107 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #936 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.19 to 0.53.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.19-0.53

- **Certified Options** : 107

- **Category Standing** : #936 of 1,352

## How does Northeast Windows USA, Inc. SL610 Slider compare thermally against Window peers?

Northeast Windows USA, Inc. SL610 Slider achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Northeast Windows USA, Inc. SL610 Slider standing at #936 of 1,352 certified Window product series, tied with 97 others at 0.23, more insulating than 23.6% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.04 before selecting Low-E tiers.

Climate coverage for Northeast Windows USA, Inc. SL610 Slider spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 20 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2018-10-03 and v7.0 data certification on 2024-03-15. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.23 conducts 138.0 BTU/hr (+6.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 107 certified glazing combinations for SL610 Slider (NFRC NEW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 20 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 59 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 44 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 50 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Elevate Windows and Doors LLC** — Inspire, Inspire Plus, Inspire Star Casement PW](https://ela-ecolandscapingassn.org/windows/models/elevate-windows-and-doors-llc-inspire-inspire-plus-inspire-star-case/) | Vinyl | 0.23 | 0.16 | 108 |
| [**NT Window, Inc.** — E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-e140-executive-n140-construction-pro-x140-energy-maste/) | Vinyl | 0.23 | 0.13 | 108 |
| [**NT Window, Inc.** — E210-Executive/N210- Construction Pro/X210- Energy Master/H210- Tradition/W210- Presidential/P210-solar Pro Double Hung](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-e210-executive-n210-construction-pro-x210-energy-maste/) | Vinyl | 0.23 | 0.12 | 108 |
| [**United Window & Door Mfg., Inc.** — 3800 / 3900 Series Fixed Window](https://ela-ecolandscapingassn.org/windows/models/united-window-door-mfg-inc-3800-3900-series-fixed-window-414208/) | Vinyl | 0.23 | 0.19 | 111 |
| [**NT Window, Inc.** — E110- Executive, N110- Construction Pro, X110- Energy Master, H110- Tradition, W110- Presidential, P110-Solar Pro SH](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-e110-executive-n110-construction-pro-x110-energy-maste/) | Vinyl | 0.23 | 0.13 | 112 |

## What other certified series does Northeast Windows USA, Inc. produce?

Compare other active Northeast Windows USA, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Awning (Projected)Min U 0.19

### [AW390 Awning](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-aw390-awning-413813/)

U-Factor 0.19–0.32 · 285 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-aw390-awning-413813/)

Casement WindowsMin U 0.19

### [CW390 Casement](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-cw390-casement-413808/)

U-Factor 0.19–0.32 · 325 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-cw390-casement-413808/)

Picture WindowMin U 0.19

### [PW4015](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-pw4015-413810/)

U-Factor 0.19–0.32 · 295 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-pw4015-413810/)

Awning (Projected)Min U 0.21

### [AW300 Awning](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-aw300-awning-413812/)

U-Factor 0.21–0.29 · 240 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-aw300-awning-413812/)

Casement WindowsMin U 0.21

### [CW300 Casement](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-cw300-casement-413811/)

U-Factor 0.21–0.32 · 266 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-cw300-casement-413811/)

Picture WindowMin U 0.21

### [PW630](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-pw630-413807/)

U-Factor 0.21–0.31 · 133 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-pw630-413807/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Northeast Windows USA, Inc. SL610 Slider appear below.

### What U-Factor and SHGC range does Northeast Windows USA, Inc. SL610 Slider achieve?

Built with Vinyl framing in Horizontal Slider (HSOX) style, Northeast Windows USA, Inc. SL610 Slider offers 107 Version 7.0 configurations from U 0.23 up to 0.31, posting +0.03 against the Window median of 0.20 with 0 Most Efficient picks.

### Does Northeast Windows USA, Inc. SL610 Slider qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern approval ends at U <= 0.22, above SL610 Slider's 0.23 minimum. However, 20 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

### What BTU/hr heat transfer results from SL610 Slider's 0.23 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 138.0 BTU/hr on SL610 Slider's lowest-U package (0.23), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.31 transfer proportionally more energy.

### Which situations make SL610 Slider the wrong window or door choice?

Do not specify SL610 Slider without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on SL610 Slider options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does SL610 Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 50 Southern-approved options within SL610 Slider spanning SHGC down to 0.19. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### Are all 107 SL610 Slider configurations ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 107 SL610 Slider options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

### What 2026 federal tax credit and Lead RRP rules apply to SL610 Slider?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How do you cross-check NFRC NEW and product line NEW-A-14 on delivery?

Match the NFRC thermal sticker for code NEW and line NEW-A-14 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Northeast Windows USA, Inc. SL610 Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
