---
title: "NT Window A100-Awning Specs (U 0.17) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-a100-awning-413846/
description: "NT Window A100-Awning (NTW-A-30, Awning (Projected), Vinyl): U-Factor 0.17-0.28, SHGC 0.11-0.21, 148 options across 4 ENERGY STAR zones. Verified against."
---

Window · Vinyl Frame NFRC NTW · Product Line NTW-A-30 ENERGY STAR Most Efficient Eligible

# NT Window, Inc. — A100-Awning · Awning (Projected)

Positioning #362/1,352 in certified Window, NT Window, Inc. A100-Awning pairs Vinyl frame construction with 148 glazing options rated between 0.11 and 0.21 SHGC across Northern, North-Central, South-Central, Southern. Across 13 certified NT Window, Inc. product families, its thermal resistance spans 0.17 to 0.28 U-Factor and the line includes 55 ENERGY STAR Most Efficient packages (37.2% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.11-0.21

- **Certified Options** : 148

- **Category Standing** : #362 of 1,352

## How does NT Window, Inc. A100-Awning compare thermally against Window peers?

NT Window, Inc. A100-Awning achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 13 certified NT Window, Inc. series, this Awning, Projected offers a 0.11 U-Factor adjustment span between 0.28 entry options and 0.17 top-performing glazing. Category standing is #362/1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%).

Regional qualification covers Northern, North-Central, South-Central, Southern. 55 configurations meet ENERGY STAR Most Efficient criteria while 12 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-04-26 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 148 certified glazing combinations for A100-Awning (NFRC NTW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 12 packages (4 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 95 packages (39 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 148 packages (39 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 148 packages (55 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Mercury Excelum, Inc.** — EOS\EOS+\ICON Double Hung](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-double-hung-413718/) | Vinyl | 0.17 | 0.16 | 148 |
| [**Lindsay Windows** — ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-climatesmart-sunview-crownview-pinnacle-healthy-fixe/) | Vinyl | 0.17 | 0.18 | 156 |
| [**Thompson Creek Window Company** — 7900 Fixed](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7900-fixed-414148/) | Vinyl | 0.17 | 0.18 | 134 |
| [**Mathews Brothers Company** — Sanford Hills Tripane Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/mathews-brothers-company-sanford-hills-tripane-fixed-casement-413666/) | Vinyl | 0.17 | 0.21 | 130 |
| [**Comfort Window Manufacturing, Inc.** — TrustSeries Awning](https://ela-ecolandscapingassn.org/windows/models/comfort-window-manufacturing-inc-trustseries-awning-413261/) | Vinyl | 0.17 | 0.16 | 171 |

## What other certified series does NT Window, Inc. produce?

Compare other active NT Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [F150/G150 RR/NC Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f150-g150-rr-nc-picture-window-413848/)

U-Factor 0.15–0.27 · 100 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f150-g150-rr-nc-picture-window-413848/)

Picture WindowMin U 0.15

### [F250/G250 RR/NC Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f250-g250-rr-nc-picture-window-413847/)

U-Factor 0.15–0.26 · 94 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f250-g250-rr-nc-picture-window-413847/)

Picture WindowMin U 0.16

### [C150 - Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c150-casement-picture-window-413844/)

U-Factor 0.16–0.28 · 140 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c150-casement-picture-window-413844/)

Casement WindowsMin U 0.17

### [C100/G100-Casement](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c100-g100-casement-413845/)

U-Factor 0.17–0.28 · 156 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c100-g100-casement-413845/)

Single HungMin U 0.17

### [F110/G110 RR/NC Single Hung](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f110-g110-rr-nc-single-hung-413849/)

U-Factor 0.17–0.29 · 96 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f110-g110-rr-nc-single-hung-413849/)

Single SliderMin U 0.17

### [F140/G140 RR/NC XO Slider](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f140-g140-rr-nc-xo-slider-413851/)

U-Factor 0.17–0.32 · 112 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f140-g140-rr-nc-xo-slider-413851/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to NT Window, Inc. A100-Awning appear below.

### What thermal performance numbers separate NT Window, Inc. A100-Awning from peers?

EPA ENERGY STAR v7.0 records 148 configurations for NT Window, Inc. A100-Awning covering Northern, North-Central, South-Central, Southern, dropping down to U 0.17 versus a 0.20 Window median. Only 55 options earn Most Efficient status.

### How does NT Window, Inc. A100-Awning satisfy Version 7.0 Northern criteria?

Yes, 12 packages satisfy Northern ENERGY STAR Version 7.0 rules in A100-Awning. Pairing multi-pane insulation down to 0.17 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### What conductive BTU/hr difference separates A100-Awning from the 0.22 Northern rule?

At U 0.17, a standard 3x5 ft (15 sq ft) A100-Awning opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.

### What homeowner profiles are a poor match for NT Window, Inc. A100-Awning?

Skip A100-Awning if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on A100-Awning options exceeding U 0.22.

### Does A100-Awning meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 148 Southern-certified options inside NT Window, Inc. A100-Awning satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.21 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Does A100-Awning carry EPA Most Efficient certification across its lineup?

No. Exactly 55 of 148 configurations (37.2%) earn ENERGY STAR Most Efficient status in A100-Awning; the remaining standard v7.0 options pass base zone limits only.

### How do the 25C sunset and pre-1978 Lead RRP rules affect A100-Awning?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current A100-Awning retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### What permanent glass etch marks verify A100-Awning after sticker removal?

Match the NFRC thermal sticker for code NTW and line NTW-A-30 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for NT Window, Inc. A100-Awning come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
