---
title: "NT Window E140-Executive, N140-Construction Pro"
url: https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-e140-executive-n140-construction-pro-x140-energy-maste/
description: "NT Window E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider NTW-A-14, Double."
---

Window · Vinyl Frame NFRC NTW · Product Line NTW-A-14

# NT Window, Inc. — E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider · Double Slider

NT Window, Inc. engineered the E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider Double Slider line for North-Central, South-Central, Southern, certifying 108 glass-spacer combinations from 0.23 to 0.30 U-Factor and 0.13 to 0.21 SHGC. Relative to other Vinyl models tracked under NFRC NTW, its minimum U-Factor is 0.04 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.13-0.21

- **Certified Options** : 108

- **Category Standing** : #936 of 1,352

## How does NT Window, Inc. E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider compare thermally against Window peers?

NT Window, Inc. E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows NT Window, Inc. E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider standing at #936 of 1,352 certified Window product series, tied with 97 others at 0.23, more insulating than 23.6% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.04 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.13 to 0.21) against ENERGY STAR Version 7.0 targets approves North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.13 lowers cooling load.

Data provenance links certification 2025-10-09 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 108 certified glazing combinations for E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider (NFRC NTW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 35 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 83 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 108 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Elevate Windows and Doors LLC** — Inspire, Inspire Plus, Inspire Star Casement PW](https://ela-ecolandscapingassn.org/windows/models/elevate-windows-and-doors-llc-inspire-inspire-plus-inspire-star-case/) | Vinyl | 0.23 | 0.16 | 108 |
| [**Northeast Windows USA, Inc.** — SL610 Slider](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-sl610-slider-413806/) | Vinyl | 0.23 | 0.19 | 107 |
| [**Northeast Windows USA, Inc.** — SH660 Single Hung](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-sh660-single-hung-413805/) | Vinyl | 0.23 | 0.19 | 105 |
| [**United Window & Door Mfg., Inc.** — 3800 / 3900 Series Fixed Window](https://ela-ecolandscapingassn.org/windows/models/united-window-door-mfg-inc-3800-3900-series-fixed-window-414208/) | Vinyl | 0.23 | 0.19 | 111 |
| [**Marvin** — Essential Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-essential-round-top-413612/) | Vinyl | 0.23 | 0.21 | 100 |

## What other certified series does NT Window, Inc. produce?

Compare other active NT Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [F150/G150 RR/NC Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f150-g150-rr-nc-picture-window-413848/)

U-Factor 0.15–0.27 · 100 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f150-g150-rr-nc-picture-window-413848/)

Picture WindowMin U 0.15

### [F250/G250 RR/NC Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f250-g250-rr-nc-picture-window-413847/)

U-Factor 0.15–0.26 · 94 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f250-g250-rr-nc-picture-window-413847/)

Picture WindowMin U 0.16

### [C150 - Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c150-casement-picture-window-413844/)

U-Factor 0.16–0.28 · 140 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c150-casement-picture-window-413844/)

Awning (Projected)Min U 0.17

### [A100-Awning](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-a100-awning-413846/)

U-Factor 0.17–0.28 · 148 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-a100-awning-413846/)

Casement WindowsMin U 0.17

### [C100/G100-Casement](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c100-g100-casement-413845/)

U-Factor 0.17–0.28 · 156 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c100-g100-casement-413845/)

Single HungMin U 0.17

### [F110/G110 RR/NC Single Hung](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f110-g110-rr-nc-single-hung-413849/)

U-Factor 0.17–0.29 · 96 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f110-g110-rr-nc-single-hung-413849/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to NT Window, Inc. E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider appear below.

### How well does E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider by NT Window, Inc. insulate relative to Window benchmarks?

Built with Vinyl framing in Dual-Slide Horizontal (HSXX) style, NT Window, Inc. E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider offers 108 Version 7.0 configurations from U 0.23 up to 0.30, posting +0.03 against the Window median of 0.20 with 0 Most Efficient picks.

### Can homeowners install E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider in cold Northern ENERGY STAR counties?

No. Because E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider reaches only 0.23 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Vinyl line strictly across North-Central, South-Central, Southern cooling or mixed markets.

### What conductive BTU/hr difference separates E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.23 U-Factor yields 138.0 BTU/hr conductive transfer (+4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### Which situations make E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

### How many E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider glazing packages pass Southern solar-heat rules?

Yes. 108 Southern-certified options inside NT Window, Inc. E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.21 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Are all 108 E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider configurations ENERGY STAR Most Efficient?

E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider holds zero Most Efficient entries across its 108 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

### Do 2026 E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How can homeowners confirm delivered NT Window, Inc. E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider units match permits?

Inspectors match the temporary NFRC sticker (U 0.23-0.30, SHGC 0.13-0.21) against permit drawings for line NTW-A-14. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for NT Window, Inc. E140-Executive, N140-Construction Pro, X140-Energy Master, H140-Tradition, W140-Presidential, P140-solar Pro Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
