---
title: "NT Window E150-Executive, N150-Construction Pro"
url: https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-e150-executive-n150-construction-pro-x150-energy-maste/
description: "NT Window E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window NTW-A-15, Picture."
---

Window · Vinyl Frame NFRC NTW · Product Line NTW-A-15 ENERGY STAR Most Efficient Eligible

# NT Window, Inc. — E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window · Picture Window

NT Window, Inc. engineered the E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window Picture Window line for Northern, North-Central, South-Central, Southern, certifying 132 glass-spacer combinations from 0.22 to 0.30 U-Factor and 0.13 to 0.23 SHGC. Relative to other Vinyl models tracked under NFRC NTW, its minimum U-Factor is 0.03 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.22

- **SHGC Range** : 0.13-0.23

- **Certified Options** : 132

- **Category Standing** : #831 of 1,352

## How does NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window compare thermally against Window peers?

NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window spans 132 NFRC test records (NTW), ranking #831 of 1,352 Window families (tied with 104 others at 0.22, more insulating than 30.8% of Window lines). Its 0.22 thermal floor compares at +0.03 against the Vinyl median (0.19).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 3 configurations meet ENERGY STAR Most Efficient criteria while 1 combination satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.22 U-Factor yields 132.0 BTU/hr transfer (matching the 0.22 Northern baseline). Manufacturer filing reflects 2018-01-10 licensing and 2024-04-26 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 132 certified glazing combinations for E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window (NFRC NTW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 1 package (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 36 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 110 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 132 packages (3 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Interstate Building Materials, Inc.** — 145/5000/5100/5200 Direct Set Picture Window](https://ela-ecolandscapingassn.org/windows/models/interstate-building-materials-inc-145-5000-5100-5200-direct-set-pict/) | Vinyl | 0.22 | 0.19 | 130 |
| [**Kasson and Keller** — 300B Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-300b-horizontal-slider-413421/) | Vinyl | 0.22 | 0.22 | 144 |
| [**Kasson and Keller** — 300C Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-300c-horizontal-slider-413415/) | Vinyl | 0.22 | 0.22 | 144 |
| [**Burris Windows** — TectView AC Picture](https://ela-ecolandscapingassn.org/windows/models/burris-windows-tectview-ac-picture-413090/) | Vinyl | 0.22 | 0.12 | 110 |
| [**Lindsay Windows** — 183 Picture Window](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-183-picture-window-413526/) | Vinyl | 0.22 | 0.15 | 102 |

## What other certified series does NT Window, Inc. produce?

Compare other active NT Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [F150/G150 RR/NC Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f150-g150-rr-nc-picture-window-413848/)

U-Factor 0.15–0.27 · 100 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f150-g150-rr-nc-picture-window-413848/)

Picture WindowMin U 0.15

### [F250/G250 RR/NC Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f250-g250-rr-nc-picture-window-413847/)

U-Factor 0.15–0.26 · 94 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f250-g250-rr-nc-picture-window-413847/)

Picture WindowMin U 0.16

### [C150 - Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c150-casement-picture-window-413844/)

U-Factor 0.16–0.28 · 140 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c150-casement-picture-window-413844/)

Awning (Projected)Min U 0.17

### [A100-Awning](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-a100-awning-413846/)

U-Factor 0.17–0.28 · 148 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-a100-awning-413846/)

Casement WindowsMin U 0.17

### [C100/G100-Casement](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c100-g100-casement-413845/)

U-Factor 0.17–0.28 · 156 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c100-g100-casement-413845/)

Single HungMin U 0.17

### [F110/G110 RR/NC Single Hung](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f110-g110-rr-nc-single-hung-413849/)

U-Factor 0.17–0.29 · 96 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f110-g110-rr-nc-single-hung-413849/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window appear below.

### What U-Factor and SHGC range does NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window achieve?

Testing puts NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window at rank #831 of 1,352 Window entries with U 0.22 to 0.30 across 132 configurations. Solar heat gain ranges between 0.13 and 0.23 across Northern, North-Central, South-Central, Southern.

### Is E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window approved for Northern Zone heating climates?

Yes, 1 package satisfy Northern ENERGY STAR Version 7.0 rules in E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window. Pairing multi-pane insulation down to 0.22 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How do you calculate winter heat conduction for NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window?

Using NFRC NTW U-Factor 0.22, a 15 sq ft Fixed Window (FIXD) assembly conducts 132.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+0.0 BTU/hr margin).

### Who should NOT choose NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window for a residential project?

Do not specify E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### How many E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 132 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window, while total line SHGC reaches 0.23 in colder packages.

### Does E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window carry EPA Most Efficient certification across its lineup?

Only 3 options out of 132 (2.3%) meet tighter Most Efficient U-Factor and SHGC thresholds in NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window, usually requiring triple-pane or upgraded Low-E coatings.

### What federal compliance checks govern 2026 E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### Where are NFRC and IGCC identification marks located on E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window?

Match the NFRC thermal sticker for code NTW and line NTW-A-15 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for NT Window, Inc. E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
