---
title: "NT Window F140/G140 RR/NC XO Slider Specs (U 0.17)"
url: https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f140-g140-rr-nc-xo-slider-413851/
description: "NT Window F140/G140 RR/NC XO Slider (NTW-A-35, Single Slider, Vinyl): U-Factor 0.17-0.32, SHGC 0.13-0.22, 112 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC NTW · Product Line NTW-A-35 ENERGY STAR Most Efficient Eligible

# NT Window, Inc. — F140/G140 RR/NC XO Slider · Single Slider

Positioning #362/1,352 in certified Window, NT Window, Inc. F140/G140 RR/NC XO Slider pairs Vinyl frame construction with 112 glazing options rated between 0.13 and 0.22 SHGC across Northern, North-Central, South-Central, Southern. Across 13 certified NT Window, Inc. product families, its thermal resistance spans 0.17 to 0.32 U-Factor and the line includes 24 ENERGY STAR Most Efficient packages (21.4% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.13-0.22

- **Certified Options** : 112

- **Category Standing** : #362 of 1,352

## How does NT Window, Inc. F140/G140 RR/NC XO Slider compare thermally against Window peers?

NT Window, Inc. F140/G140 RR/NC XO Slider achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows NT Window, Inc. F140/G140 RR/NC XO Slider standing at #362 of 1,352 certified Window product series, tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%. Comparing Vinyl profiles alone (median 0.19) shows -0.02 before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 24 configurations meet ENERGY STAR Most Efficient criteria while 12 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors NTW to 2026-08-06 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 102.0 BTU/hr conductive loss (-22.7% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 112 certified glazing combinations for F140/G140 RR/NC XO Slider (NFRC NTW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 12 packages (0 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 48 packages (16 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 104 packages (16 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 112 packages (24 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Energex Window Alliance** — Energex Double Hung](https://ela-ecolandscapingassn.org/windows/models/energex-window-alliance-energex-double-hung-413196/) | Vinyl | 0.17 | 0.13 | 107 |
| [**Mathews Brothers Company** — Sanford Hills Tripane Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/mathews-brothers-company-sanford-hills-tripane-fixed-casement-413666/) | Vinyl | 0.17 | 0.21 | 130 |
| [**OKNA Windows & Doors Mfg** — 820 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-820-horizontal-slider-413868/) | Vinyl | 0.17 | 0.14 | 90 |
| [**Thompson Creek Window Company** — 7900 Fixed](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7900-fixed-414148/) | Vinyl | 0.17 | 0.18 | 134 |
| [**Wallside Windows** — PC-V Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-pc-v-casement-picture-window-414322/) | Vinyl | 0.17 | 0.18 | 88 |

## What other certified series does NT Window, Inc. produce?

Compare other active NT Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [F150/G150 RR/NC Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f150-g150-rr-nc-picture-window-413848/)

U-Factor 0.15–0.27 · 100 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f150-g150-rr-nc-picture-window-413848/)

Picture WindowMin U 0.15

### [F250/G250 RR/NC Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f250-g250-rr-nc-picture-window-413847/)

U-Factor 0.15–0.26 · 94 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f250-g250-rr-nc-picture-window-413847/)

Picture WindowMin U 0.16

### [C150 - Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c150-casement-picture-window-413844/)

U-Factor 0.16–0.28 · 140 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c150-casement-picture-window-413844/)

Awning (Projected)Min U 0.17

### [A100-Awning](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-a100-awning-413846/)

U-Factor 0.17–0.28 · 148 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-a100-awning-413846/)

Casement WindowsMin U 0.17

### [C100/G100-Casement](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c100-g100-casement-413845/)

U-Factor 0.17–0.28 · 156 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c100-g100-casement-413845/)

Single HungMin U 0.17

### [F110/G110 RR/NC Single Hung](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f110-g110-rr-nc-single-hung-413849/)

U-Factor 0.17–0.29 · 96 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f110-g110-rr-nc-single-hung-413849/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to NT Window, Inc. F140/G140 RR/NC XO Slider appear below.

### What U-Factor and SHGC range does NT Window, Inc. F140/G140 RR/NC XO Slider achieve?

Built with Vinyl framing in Horizontal Slider (HSOX) style, NT Window, Inc. F140/G140 RR/NC XO Slider offers 112 Version 7.0 configurations from U 0.17 up to 0.32, posting -0.03 against the Window median of 0.20 with 24 Most Efficient picks.

### Does NT Window, Inc. F140/G140 RR/NC XO Slider qualify for the ENERGY STAR Northern Zone?

NT Window, Inc. F140/G140 RR/NC XO Slider supplies 12 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

### What conductive BTU/hr difference separates F140/G140 RR/NC XO Slider from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), F140/G140 RR/NC XO Slider at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### Which situations make F140/G140 RR/NC XO Slider the wrong window or door choice?

Do not specify F140/G140 RR/NC XO Slider without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on F140/G140 RR/NC XO Slider options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### How many F140/G140 RR/NC XO Slider glazing packages pass Southern solar-heat rules?

Warm-climate homeowners have 112 Southern-approved options within F140/G140 RR/NC XO Slider spanning SHGC down to 0.13. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### What glazing share inside F140/G140 RR/NC XO Slider qualifies as Most Efficient?

EPA lists 24 Most Efficient options (21.4% share) inside NT Window, Inc. F140/G140 RR/NC XO Slider, out of 112 total Version 7.0 entries.

### How do the 25C sunset and pre-1978 Lead RRP rules affect F140/G140 RR/NC XO Slider?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How do building inspectors verify F140/G140 RR/NC XO Slider glass specs on job sites?

Match the NFRC thermal sticker for code NTW and line NTW-A-35 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for NT Window, Inc. F140/G140 RR/NC XO Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
