---
title: "NT Window F150/G150 RR/NC Picture Window Specs (U 0.15)"
url: https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f150-g150-rr-nc-picture-window-413848/
description: "NT Window F150/G150 RR/NC Picture Window (NTW-A-32, Picture Window, Vinyl): U-Factor 0.15-0.27, SHGC 0.14-0.23, 100 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC NTW · Product Line NTW-A-32 ENERGY STAR Most Efficient Eligible

# NT Window, Inc. — F150/G150 RR/NC Picture Window · Picture Window

NT Window, Inc. engineered the F150/G150 RR/NC Picture Window Picture Window line for Northern, North-Central, South-Central, Southern, certifying 100 glass-spacer combinations from 0.15 to 0.27 U-Factor and 0.14 to 0.23 SHGC. Relative to other Vinyl models tracked under NFRC NTW, its minimum U-Factor is 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.15

- **SHGC Range** : 0.14-0.23

- **Certified Options** : 100

- **Category Standing** : #136 of 1,352

## How does NT Window, Inc. F150/G150 RR/NC Picture Window compare thermally against Window peers?

NT Window, Inc. F150/G150 RR/NC Picture Window achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places NT Window, Inc. F150/G150 RR/NC Picture Window at rank #136 of 1,352 (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.14-0.23 band.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 39 configurations meet ENERGY STAR Most Efficient criteria while 28 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2026-02-04 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 90.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 100 certified glazing combinations for F150/G150 RR/NC Picture Window (NFRC NTW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 28 packages (5 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 74 packages (20 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 100 packages (20 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 100 packages (39 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**OKNA Windows & Doors Mfg** — PW810 Picture Window](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-pw810-picture-window-413866/) | Vinyl | 0.15 | 0.15 | 76 |
| [**OKNA Windows & Doors Mfg** — 7520 Double Slider](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7520-double-slider-413873/) | Vinyl | 0.15 | 0.15 | 68 |
| [**Mathews Brothers Company** — Sanford Hills Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/mathews-brothers-company-sanford-hills-fixed-casement-413663/) | Vinyl | 0.15 | 0.24 | 64 |
| [**OKNA Windows & Doors Mfg** — 7500 Double Hung](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7500-double-hung-413874/) | Vinyl | 0.15 | 0.15 | 59 |
| [**Vector Windows** — Envision Casement Picture](https://ela-ecolandscapingassn.org/windows/models/vector-windows-envision-casement-picture-414024/) | Vinyl | 0.15 | 0.18 | 57 |

## What other certified series does NT Window, Inc. produce?

Compare other active NT Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [F250/G250 RR/NC Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f250-g250-rr-nc-picture-window-413847/)

U-Factor 0.15–0.26 · 94 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f250-g250-rr-nc-picture-window-413847/)

Picture WindowMin U 0.16

### [C150 - Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c150-casement-picture-window-413844/)

U-Factor 0.16–0.28 · 140 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c150-casement-picture-window-413844/)

Awning (Projected)Min U 0.17

### [A100-Awning](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-a100-awning-413846/)

U-Factor 0.17–0.28 · 148 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-a100-awning-413846/)

Casement WindowsMin U 0.17

### [C100/G100-Casement](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c100-g100-casement-413845/)

U-Factor 0.17–0.28 · 156 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c100-g100-casement-413845/)

Single HungMin U 0.17

### [F110/G110 RR/NC Single Hung](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f110-g110-rr-nc-single-hung-413849/)

U-Factor 0.17–0.29 · 96 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f110-g110-rr-nc-single-hung-413849/)

Single SliderMin U 0.17

### [F140/G140 RR/NC XO Slider](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f140-g140-rr-nc-xo-slider-413851/)

U-Factor 0.17–0.32 · 112 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f140-g140-rr-nc-xo-slider-413851/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to NT Window, Inc. F150/G150 RR/NC Picture Window appear below.

### What thermal performance numbers separate NT Window, Inc. F150/G150 RR/NC Picture Window from peers?

NT Window, Inc. F150/G150 RR/NC Picture Window spans 100 certified configurations with U-Factors between 0.15 and 0.27 and SHGC values from 0.14 to 0.23. Ranked #136 of 1,352 Window families, it carries 39 Most Efficient options.

### Does NT Window, Inc. F150/G150 RR/NC Picture Window qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 28 F150/G150 RR/NC Picture Window packages (U floor 0.15, SHGC >= 0.17). Because the complete series stretches up to U 0.27, specify the cold-climate glass code explicitly.

### How do you calculate winter heat conduction for NT Window, Inc. F150/G150 RR/NC Picture Window?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.15 U-Factor yields 90.0 BTU/hr conductive transfer (-31.8% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### Who should NOT choose NT Window, Inc. F150/G150 RR/NC Picture Window for a residential project?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on F150/G150 RR/NC Picture Window options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

### Is F150/G150 RR/NC Picture Window suitable for sunbelt cooling-dominated homes?

Exactly 100 F150/G150 RR/NC Picture Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.14 rather than higher 0.23 glass.

### Are all 100 F150/G150 RR/NC Picture Window configurations ENERGY STAR Most Efficient?

Within F150/G150 RR/NC Picture Window, 39.0% (39 of 100) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

### How do the 25C sunset and pre-1978 Lead RRP rules affect F150/G150 RR/NC Picture Window?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 NT Window, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### Where are NFRC and IGCC identification marks located on F150/G150 RR/NC Picture Window?

Match the NFRC thermal sticker for code NTW and line NTW-A-32 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for NT Window, Inc. F150/G150 RR/NC Picture Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
