title: "NT Window F210/G210 RR/NC Double Hung Specs (U 0.18)"
url: https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f210-g210-rr-nc-double-hung-413850/
description: "NT Window F210/G210 RR/NC Double Hung (NTW-A-34, Double Hung, Vinyl): U-Factor 0.18-0.31, SHGC 0.12-0.21, 112 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC NTW · Product Line NTW-A-34 ENERGY STAR Most Efficient Eligible

# NT Window, Inc. — F210/G210 RR/NC Double Hung · Double Hung

Positioning #477/1,352 in certified Window, NT Window, Inc. F210/G210 RR/NC Double Hung pairs Vinyl frame construction with 112 glazing options rated between 0.12 and 0.21 SHGC across Northern, North-Central, South-Central, Southern. Across 13 certified NT Window, Inc. product families, its thermal resistance spans 0.18 to 0.31 U-Factor and the line includes 24 ENERGY STAR Most Efficient packages (21.4% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.18

- **SHGC Range** : 0.12-0.21

- **Certified Options** : 112

- **Category Standing** : #477 of 1,352

## How does NT Window, Inc. F210/G210 RR/NC Double Hung compare thermally against Window peers?

NT Window, Inc. F210/G210 RR/NC Double Hung achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows NT Window, Inc. F210/G210 RR/NC Double Hung standing at #477 of 1,352 certified Window product series, tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%. Comparing Vinyl profiles alone (median 0.19) shows -0.01 before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 24 configurations meet ENERGY STAR Most Efficient criteria while 8 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors NTW to 2026-08-06 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 108.0 BTU/hr conductive loss (-18.2% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 112 certified glazing combinations for F210/G210 RR/NC Double Hung (NFRC NTW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 8 packages (0 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 48 packages (16 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 104 packages (16 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 112 packages (24 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Vinyl Kraft, Inc.** — TRUSTGARD / 5500 / 5300 / 5200 DH](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-trustgard-5500-5300-5200-dh-414224/) | Vinyl | 0.18 | 0.16 | 124 |
| [**Wallside Windows** — PW - Picture Window](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-pw-picture-window-414319/) | Vinyl | 0.18 | 0.19 | 82 |
| [**Ideal Window Manufacturing** — Professional, Perfect Fit, Majestic, Lifescape, Platinum Double Hung](https://ela-ecolandscapingassn.org/windows/models/ideal-window-manufacturing-professional-perfect-fit-majestic-lifesca/) | Vinyl | 0.18 | 0.14 | 80 |
| [**Mercury Excelum, Inc.** — EOS\EOS+\ICON Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-horizontal-slider-413723/) | Vinyl | 0.18 | 0.16 | 78 |
| [**National Vinyl, LLC** — TG/NW3/Destiny/Duratrust/Clarion/Sentinel Casement](https://ela-ecolandscapingassn.org/windows/models/national-vinyl-llc-tg-nw3-destiny-duratrust-clarion-sentinel-casemen/) | Vinyl | 0.18 | 0.18 | 75 |

## What other certified series does NT Window, Inc. produce?

Compare other active NT Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [F150/G150 RR/NC Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f150-g150-rr-nc-picture-window-413848/)

U-Factor 0.15–0.27 · 100 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f150-g150-rr-nc-picture-window-413848/)

Picture WindowMin U 0.15

### [F250/G250 RR/NC Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f250-g250-rr-nc-picture-window-413847/)

U-Factor 0.15–0.26 · 94 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f250-g250-rr-nc-picture-window-413847/)

Picture WindowMin U 0.16

### [C150 - Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c150-casement-picture-window-413844/)

U-Factor 0.16–0.28 · 140 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c150-casement-picture-window-413844/)

Awning (Projected)Min U 0.17

### [A100-Awning](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-a100-awning-413846/)

U-Factor 0.17–0.28 · 148 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-a100-awning-413846/)

Casement WindowsMin U 0.17

### [C100/G100-Casement](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c100-g100-casement-413845/)

U-Factor 0.17–0.28 · 156 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c100-g100-casement-413845/)

Single HungMin U 0.17

### [F110/G110 RR/NC Single Hung](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f110-g110-rr-nc-single-hung-413849/)

U-Factor 0.17–0.29 · 96 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f110-g110-rr-nc-single-hung-413849/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to NT Window, Inc. F210/G210 RR/NC Double Hung appear below.

### Where does NT Window, Inc. F210/G210 RR/NC Double Hung stand thermally among ENERGY STAR Window lines?

Across 112 tested NFRC glazing configurations, NT Window, Inc. F210/G210 RR/NC Double Hung with Vinyl framing and Double-Hung (VSDH) style reaches a 0.18 minimum U-Factor and 0.12-0.21 SHGC band. It places #477 among 1,352 Window series—top 41.6%.

### Does NT Window, Inc. F210/G210 RR/NC Double Hung qualify for the ENERGY STAR Northern Zone?

NT Window, Inc. F210/G210 RR/NC Double Hung supplies 8 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.31, so inspect the NFRC order sheet before purchase.

### How does a 3x5 ft F210/G210 RR/NC Double Hung window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.18 U-Factor yields 108.0 BTU/hr conductive transfer (-18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### When should a buyer skip NT Window, Inc. F210/G210 RR/NC Double Hung and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on F210/G210 RR/NC Double Hung options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### What Southern ENERGY STAR v7.0 options exist in F210/G210 RR/NC Double Hung?

Yes. 112 Southern-certified options inside NT Window, Inc. F210/G210 RR/NC Double Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.21 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Which package tier in F210/G210 RR/NC Double Hung holds Most Efficient recognition?

Only 24 options out of 112 (21.4%) meet tighter Most Efficient U-Factor and SHGC thresholds in NT Window, Inc. F210/G210 RR/NC Double Hung, usually requiring triple-pane or upgraded Low-E coatings.

### Can homeowners claim Form 5695 credits on NT Window, Inc. F210/G210 RR/NC Double Hung in 2026?

Any F210/G210 RR/NC Double Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How do building inspectors verify F210/G210 RR/NC Double Hung glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line NTW-A-34 and NFRC ID NTW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for NT Window, Inc. F210/G210 RR/NC Double Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)