title: "NT Window F250/G250 RR/NC Picture Window Specs (U 0.15)"
url: https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f250-g250-rr-nc-picture-window-413847/
description: "NT Window F250/G250 RR/NC Picture Window (NTW-A-31, Picture Window, Vinyl): U-Factor 0.15-0.26, SHGC 0.14-0.24, 94 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC NTW · Product Line NTW-A-31 ENERGY STAR Most Efficient Eligible

# NT Window, Inc. — F250/G250 RR/NC Picture Window · Picture Window

NT Window, Inc. engineered the F250/G250 RR/NC Picture Window Picture Window line for Northern, North-Central, South-Central, Southern, certifying 94 glass-spacer combinations from 0.15 to 0.26 U-Factor and 0.14 to 0.24 SHGC. Relative to other Vinyl models tracked under NFRC NTW, its minimum U-Factor is 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.15

- **SHGC Range** : 0.14-0.24

- **Certified Options** : 94

- **Category Standing** : #136 of 1,352

## How does NT Window, Inc. F250/G250 RR/NC Picture Window compare thermally against Window peers?

NT Window, Inc. F250/G250 RR/NC Picture Window achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), F250/G250 RR/NC Picture Window reaches 0.15 on its lowest-conductivity package — #89 of 1,009 in Vinyl, tied with 80 others at 0.15, more insulating than 83.3% of Vinyl lines, top 16.7% (-0.04 vs Vinyl peers). Pairing NFRC ID NTW across multi-pane fills shifts U-Factor from 0.26 down toward 0.15.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 37 configurations meet ENERGY STAR Most Efficient criteria while 36 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 90.0 BTU/hr (-31.8% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2025-11-19.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 94 certified glazing combinations for F250/G250 RR/NC Picture Window (NFRC NTW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 36 packages (10 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 74 packages (28 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 88 packages (28 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 88 packages (37 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**OKNA Windows & Doors Mfg** — PW810 Picture Window](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-pw810-picture-window-413866/) | Vinyl | 0.15 | 0.15 | 76 |
| [**OKNA Windows & Doors Mfg** — 7520 Double Slider](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7520-double-slider-413873/) | Vinyl | 0.15 | 0.15 | 68 |
| [**Mathews Brothers Company** — Sanford Hills Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/mathews-brothers-company-sanford-hills-fixed-casement-413663/) | Vinyl | 0.15 | 0.24 | 64 |
| [**OKNA Windows & Doors Mfg** — 7500 Double Hung](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7500-double-hung-413874/) | Vinyl | 0.15 | 0.15 | 59 |
| [**Vector Windows** — Envision Casement Picture](https://ela-ecolandscapingassn.org/windows/models/vector-windows-envision-casement-picture-414024/) | Vinyl | 0.15 | 0.18 | 57 |

## What other certified series does NT Window, Inc. produce?

Compare other active NT Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [F150/G150 RR/NC Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f150-g150-rr-nc-picture-window-413848/)

U-Factor 0.15–0.27 · 100 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f150-g150-rr-nc-picture-window-413848/)

Picture WindowMin U 0.16

### [C150 - Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c150-casement-picture-window-413844/)

U-Factor 0.16–0.28 · 140 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c150-casement-picture-window-413844/)

Awning (Projected)Min U 0.17

### [A100-Awning](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-a100-awning-413846/)

U-Factor 0.17–0.28 · 148 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-a100-awning-413846/)

Casement WindowsMin U 0.17

### [C100/G100-Casement](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c100-g100-casement-413845/)

U-Factor 0.17–0.28 · 156 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c100-g100-casement-413845/)

Single HungMin U 0.17

### [F110/G110 RR/NC Single Hung](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f110-g110-rr-nc-single-hung-413849/)

U-Factor 0.17–0.29 · 96 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f110-g110-rr-nc-single-hung-413849/)

Single SliderMin U 0.17

### [F140/G140 RR/NC XO Slider](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f140-g140-rr-nc-xo-slider-413851/)

U-Factor 0.17–0.32 · 112 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f140-g140-rr-nc-xo-slider-413851/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to NT Window, Inc. F250/G250 RR/NC Picture Window appear below.

### Where does NT Window, Inc. F250/G250 RR/NC Picture Window stand thermally among ENERGY STAR Window lines?

Built with Vinyl framing in Fixed Window (FIXD) style, NT Window, Inc. F250/G250 RR/NC Picture Window offers 94 Version 7.0 configurations from U 0.15 up to 0.26, posting -0.05 against the Window median of 0.20 with 37 Most Efficient picks.

### How does NT Window, Inc. F250/G250 RR/NC Picture Window satisfy Version 7.0 Northern criteria?

NT Window, Inc. F250/G250 RR/NC Picture Window supplies 36 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.26, so inspect the NFRC order sheet before purchase.

### What conductive BTU/hr difference separates F250/G250 RR/NC Picture Window from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.15 U-Factor yields 90.0 BTU/hr conductive transfer (-31.8% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What homeowner profiles are a poor match for NT Window, Inc. F250/G250 RR/NC Picture Window?

Skip F250/G250 RR/NC Picture Window if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on F250/G250 RR/NC Picture Window options exceeding U 0.22.

### What Southern ENERGY STAR v7.0 options exist in F250/G250 RR/NC Picture Window?

Yes. 88 Southern-certified options inside NT Window, Inc. F250/G250 RR/NC Picture Window satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.24 SHGC on west-facing glass to avoid excess afternoon solar gain.

### What glazing share inside F250/G250 RR/NC Picture Window qualifies as Most Efficient?

Not every package qualifies: 37 of 94 F250/G250 RR/NC Picture Window glazing builds earn Most Efficient recognition (39.4%), while other variants sit on the standard Version 7.0 tier.

### What federal compliance checks govern 2026 F250/G250 RR/NC Picture Window window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current F250/G250 RR/NC Picture Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### Where are NFRC and IGCC identification marks located on F250/G250 RR/NC Picture Window?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code NTW and product line NTW-A-31, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for NT Window, Inc. F250/G250 RR/NC Picture Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)