---
title: "OKNA Windows & Doors Mfg 400 Double Hung Specs"
url: https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-400-double-hung-413860/
description: "OKNA Windows & Doors Mfg 400 Double Hung (OKW-K-22, Double Hung, Vinyl): U-Factor 0.17-0.30, SHGC 0.14-0.22, 56 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC OKW · Product Line OKW-K-22 ENERGY STAR Most Efficient Eligible

# OKNA Windows & Doors Mfg — 400 Double Hung · Double Hung

With a minimum U-Factor of 0.17—-0.03 compared against the 0.20 Window median—OKNA Windows & Doors Mfg 400 Double Hung spans 56 tested options across Northern, North-Central, South-Central, Southern up to 0.30 U-Factor. Carrying NFRC CPD code OKW, the Vinyl assembly includes 25 ENERGY STAR Most Efficient packages (44.6% of line) and offers SHGC packages between 0.14 and 0.22.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.14-0.22

- **Certified Options** : 56

- **Category Standing** : #362 of 1,352

## How does OKNA Windows & Doors Mfg 400 Double Hung compare thermally against Window peers?

OKNA Windows & Doors Mfg 400 Double Hung achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows OKNA Windows & Doors Mfg 400 Double Hung standing at #362 of 1,352 certified Window product series, tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%. Comparing Vinyl profiles alone (median 0.19) shows -0.02 before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 25 configurations meet ENERGY STAR Most Efficient criteria while 14 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-05-16 and FENSTAR license 2018-09-05 inside EPA Version 7.0 tables. Heat transfer computes to 102.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 56 certified glazing combinations for 400 Double Hung (NFRC OKW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 14 packages (8 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 32 packages (16 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 46 packages (16 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 56 packages (25 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Seven D Windows and Door LLC** — 7700/7800 Awning](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-awning-414053/) | Vinyl | 0.17 | 0.19 | 55 |
| [**Seven D Windows and Door LLC** — 7700/7800 Casement](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-casement-414052/) | Vinyl | 0.17 | 0.19 | 55 |
| [**National Vinyl, LLC** — TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/national-vinyl-llc-tg-nw3-destiny-duratrust-clarion-northwind-br-hor/) | Vinyl | 0.17 | 0.22 | 51 |
| [**Energex Window Alliance** — Energex Picture Window](https://ela-ecolandscapingassn.org/windows/models/energex-window-alliance-energex-picture-window-413197/) | Vinyl | 0.17 | 0.14 | 66 |
| [**Vector Windows** — Envision Glider](https://ela-ecolandscapingassn.org/windows/models/vector-windows-envision-glider-414029/) | Vinyl | 0.17 | 0.17 | 67 |

## What other certified series does OKNA Windows & Doors Mfg produce?

Compare other active OKNA Windows & Doors Mfg certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [7580 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7580-casement-picture-window-413876/)

U-Factor 0.13–0.26 · 73 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7580-casement-picture-window-413876/)

Picture WindowMin U 0.14

### [7510 Picture Window](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7510-picture-window-413875/)

U-Factor 0.14–0.27 · 62 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7510-picture-window-413875/)

Awning (Projected)Min U 0.14

### [7560 Awning](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7560-awning-413878/)

U-Factor 0.14–0.25 · 64 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7560-awning-413878/)

Casement WindowsMin U 0.14

### [7560 Casement](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7560-casement-413877/)

U-Factor 0.14–0.26 · 76 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7560-casement-413877/)

Picture WindowMin U 0.14

### [PW 710/4710](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-pw-710-4710-413863/)

U-Factor 0.14–0.28 · 96 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-pw-710-4710-413863/)

Picture WindowMin U 0.14

### [PW610-6610-510-5510](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-pw610-6610-510-5510-413871/)

U-Factor 0.14–0.29 · 73 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-pw610-6610-510-5510-413871/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to OKNA Windows & Doors Mfg 400 Double Hung appear below.

### What U-Factor and SHGC range does OKNA Windows & Doors Mfg 400 Double Hung achieve?

OKNA Windows & Doors Mfg 400 Double Hung spans 56 certified configurations with U-Factors between 0.17 and 0.30 and SHGC values from 0.14 to 0.22. Ranked #362 of 1,352 Window families, it carries 25 Most Efficient options.

### Which glazing options in OKNA Windows & Doors Mfg 400 Double Hung meet Northern climate limits?

OKNA Windows & Doors Mfg 400 Double Hung supplies 14 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.30, so inspect the NFRC order sheet before purchase.

### How much winter heat loss does 400 Double Hung conduct across a 15 sq ft opening?

At U 0.17, a standard 3x5 ft (15 sq ft) 400 Double Hung opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.

### What are the practical limitations of specifying 400 Double Hung?

Do not specify 400 Double Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Double Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does 400 Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 56 Southern-certified options inside OKNA Windows & Doors Mfg 400 Double Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.22 SHGC on west-facing glass to avoid excess afternoon solar gain.

### How many OKNA Windows & Doors Mfg 400 Double Hung variants earn ENERGY STAR Most Efficient?

No. Exactly 25 of 56 configurations (44.6%) earn ENERGY STAR Most Efficient status in 400 Double Hung; the remaining standard v7.0 options pass base zone limits only.

### Can homeowners claim Form 5695 credits on OKNA Windows & Doors Mfg 400 Double Hung in 2026?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 400 Double Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### Where are NFRC and IGCC identification marks located on 400 Double Hung?

Inspectors match the temporary NFRC sticker (U 0.17-0.30, SHGC 0.14-0.22) against permit drawings for line OKW-K-22. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for OKNA Windows & Doors Mfg 400 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
