title: "OKNA Windows & Doors Mfg 7520 Double Slider Specs"
url: https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7520-double-slider-413873/
description: "OKNA Windows & Doors Mfg 7520 Double Slider (OKW-K-46, Double Slider, Vinyl): U-Factor 0.15-0.28, SHGC 0.15-0.23, 68 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC OKW · Product Line OKW-K-46 ENERGY STAR Most Efficient Eligible

# OKNA Windows & Doors Mfg — 7520 Double Slider · Double Slider

Positioning #136/1,352 in certified Window, OKNA Windows & Doors Mfg 7520 Double Slider pairs Vinyl frame construction with 68 glazing options rated between 0.15 and 0.23 SHGC across Northern, North-Central, South-Central, Southern. Across 21 certified OKNA Windows & Doors Mfg product families, its thermal resistance spans 0.15 to 0.28 U-Factor and the line includes 36 ENERGY STAR Most Efficient packages (52.9% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.15

- **SHGC Range** : 0.15-0.23

- **Certified Options** : 68

- **Category Standing** : #136 of 1,352

## How does OKNA Windows & Doors Mfg 7520 Double Slider compare thermally against Window peers?

OKNA Windows & Doors Mfg 7520 Double Slider achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 7520 Double Slider is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.15-0.28.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 36 configurations meet ENERGY STAR Most Efficient criteria while 28 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-09-05 and v7.0 data certification on 2025-03-04. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.15 conducts 90.0 BTU/hr (-42.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 68 certified glazing combinations for 7520 Double Slider (NFRC OKW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 28 packages (20 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 36 packages (36 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 68 packages (36 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 68 packages (36 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Mathews Brothers Company** — Sanford Hills Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/mathews-brothers-company-sanford-hills-fixed-casement-413663/) | Vinyl | 0.15 | 0.24 | 64 |
| [**Vector Windows** — Envision Casement Picture](https://ela-ecolandscapingassn.org/windows/models/vector-windows-envision-casement-picture-414024/) | Vinyl | 0.15 | 0.18 | 57 |
| [**Kohltech International, Ltd.** — Select Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-select-fixed-casement-413490/) | Vinyl | 0.15 | 0.20 | 50 |
| [**Kohltech International, Ltd.** — Select Wide Picture Window](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-select-wide-picture-window-413487/) | Vinyl | 0.15 | 0.20 | 50 |
| [**NT Window, Inc.** — F250/G250 RR/NC Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f250-g250-rr-nc-picture-window-413847/) | Vinyl | 0.15 | 0.14 | 94 |

## What other certified series does OKNA Windows & Doors Mfg produce?

Compare other active OKNA Windows & Doors Mfg certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [7580 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7580-casement-picture-window-413876/)

U-Factor 0.13–0.26 · 73 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7580-casement-picture-window-413876/)

Picture WindowMin U 0.14

### [7510 Picture Window](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7510-picture-window-413875/)

U-Factor 0.14–0.27 · 62 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7510-picture-window-413875/)

Awning (Projected)Min U 0.14

### [7560 Awning](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7560-awning-413878/)

U-Factor 0.14–0.25 · 64 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7560-awning-413878/)

Casement WindowsMin U 0.14

### [7560 Casement](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7560-casement-413877/)

U-Factor 0.14–0.26 · 76 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7560-casement-413877/)

Picture WindowMin U 0.14

### [PW 710/4710](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-pw-710-4710-413863/)

U-Factor 0.14–0.28 · 96 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-pw-710-4710-413863/)

Picture WindowMin U 0.14

### [PW610-6610-510-5510](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-pw610-6610-510-5510-413871/)

U-Factor 0.14–0.29 · 73 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-pw610-6610-510-5510-413871/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to OKNA Windows & Doors Mfg 7520 Double Slider appear below.

### How efficient is OKNA Windows & Doors Mfg 7520 Double Slider compared with peer Window models?

Across 68 tested NFRC glazing configurations, OKNA Windows & Doors Mfg 7520 Double Slider with Vinyl framing and Dual-Slide Horizontal (HSXX) style reaches a 0.15 minimum U-Factor and 0.15-0.23 SHGC band. It places #136 among 1,352 Window series—top 18.4%.

### Can homeowners install 7520 Double Slider in cold Northern ENERGY STAR counties?

Prescriptive Northern compliance covers 28 7520 Double Slider packages (U floor 0.15, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

### How much winter heat loss does 7520 Double Slider conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.15 U-Factor yields 90.0 BTU/hr conductive transfer (-31.8% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### Which situations make 7520 Double Slider the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 7520 Double Slider options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

### Is 7520 Double Slider suitable for sunbelt cooling-dominated homes?

Across Northern, North-Central, South-Central, Southern, 68 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside OKNA Windows & Doors Mfg 7520 Double Slider, while total line SHGC reaches 0.23 in colder packages.

### Does 7520 Double Slider carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 36 of 68 7520 Double Slider glazing builds earn Most Efficient recognition (52.9%), while other variants sit on the standard Version 7.0 tier.

### What federal compliance checks govern 2026 7520 Double Slider window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How do you cross-check NFRC OKW and product line OKW-K-46 on delivery?

Inspectors match the temporary NFRC sticker (U 0.15-0.28, SHGC 0.15-0.23) against permit drawings for line OKW-K-46. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for OKNA Windows & Doors Mfg 7520 Double Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)