title: "OKNA Windows & Doors Mfg PW810 Picture Window Specs"
url: https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-pw810-picture-window-413866/
description: "OKNA Windows & Doors Mfg PW810 Picture Window (OKW-K-28, Picture Window, Vinyl): U-Factor 0.15-0.29, SHGC 0.15-0.28, 76 options across 4 ENERGY STAR."
---

Window · Vinyl Frame NFRC OKW · Product Line OKW-K-28 ENERGY STAR Most Efficient Eligible

# OKNA Windows & Doors Mfg — PW810 Picture Window · Picture Window

EPA ENERGY STAR Version 7.0 certifies 76 variants inside OKNA Windows & Doors Mfg PW810 Picture Window, combining Vinyl frame construction with U-Factors spanning 0.15 to 0.29 and SHGC 0.15 to 0.28. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #136 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.15

- **SHGC Range** : 0.15-0.28

- **Certified Options** : 76

- **Category Standing** : #136 of 1,352

## How does OKNA Windows & Doors Mfg PW810 Picture Window compare thermally against Window peers?

OKNA Windows & Doors Mfg PW810 Picture Window achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), PW810 Picture Window is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.15-0.29.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 40 configurations meet ENERGY STAR Most Efficient criteria while 32 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-09-05 and v7.0 data certification on 2024-12-02. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.15 conducts 90.0 BTU/hr (-42.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 76 certified glazing combinations for PW810 Picture Window (NFRC OKW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 32 packages (20 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 52 packages (32 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 68 packages (32 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 70 packages (40 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Mathews Brothers Company** — Sanford Hills Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/mathews-brothers-company-sanford-hills-fixed-casement-413663/) | Vinyl | 0.15 | 0.24 | 64 |
| [**NT Window, Inc.** — F250/G250 RR/NC Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f250-g250-rr-nc-picture-window-413847/) | Vinyl | 0.15 | 0.14 | 94 |
| [**Vector Windows** — Envision Casement Picture](https://ela-ecolandscapingassn.org/windows/models/vector-windows-envision-casement-picture-414024/) | Vinyl | 0.15 | 0.18 | 57 |
| [**NT Window, Inc.** — F150/G150 RR/NC Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-f150-g150-rr-nc-picture-window-413848/) | Vinyl | 0.15 | 0.14 | 100 |
| [**Kohltech International, Ltd.** — Select Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-select-fixed-casement-413490/) | Vinyl | 0.15 | 0.20 | 50 |

## What other certified series does OKNA Windows & Doors Mfg produce?

Compare other active OKNA Windows & Doors Mfg certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [7580 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7580-casement-picture-window-413876/)

U-Factor 0.13–0.26 · 73 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7580-casement-picture-window-413876/)

Picture WindowMin U 0.14

### [7510 Picture Window](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7510-picture-window-413875/)

U-Factor 0.14–0.27 · 62 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7510-picture-window-413875/)

Awning (Projected)Min U 0.14

### [7560 Awning](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7560-awning-413878/)

U-Factor 0.14–0.25 · 64 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7560-awning-413878/)

Casement WindowsMin U 0.14

### [7560 Casement](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7560-casement-413877/)

U-Factor 0.14–0.26 · 76 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7560-casement-413877/)

Picture WindowMin U 0.14

### [PW 710/4710](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-pw-710-4710-413863/)

U-Factor 0.14–0.28 · 96 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-pw-710-4710-413863/)

Picture WindowMin U 0.14

### [PW610-6610-510-5510](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-pw610-6610-510-5510-413871/)

U-Factor 0.14–0.29 · 73 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-pw610-6610-510-5510-413871/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to OKNA Windows & Doors Mfg PW810 Picture Window appear below.

### What U-Factor and SHGC range does OKNA Windows & Doors Mfg PW810 Picture Window achieve?

Testing puts OKNA Windows & Doors Mfg PW810 Picture Window at rank #136 of 1,352 Window entries with U 0.15 to 0.29 across 76 configurations. Solar heat gain ranges between 0.15 and 0.28 across Northern, North-Central, South-Central, Southern.

### How does OKNA Windows & Doors Mfg PW810 Picture Window satisfy Version 7.0 Northern criteria?

OKNA Windows & Doors Mfg PW810 Picture Window supplies 32 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.29, so inspect the NFRC order sheet before purchase.

### How do you calculate winter heat conduction for OKNA Windows & Doors Mfg PW810 Picture Window?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 90.0 BTU/hr on PW810 Picture Window's lowest-U package (0.15), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.29 transfer proportionally more energy.

### What are the practical limitations of specifying PW810 Picture Window?

Skip PW810 Picture Window if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on PW810 Picture Window options exceeding U 0.22.

### Does PW810 Picture Window meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 70 PW810 Picture Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.15 rather than higher 0.28 glass.

### Are all 76 PW810 Picture Window configurations ENERGY STAR Most Efficient?

Only 40 options out of 76 (52.6%) meet tighter Most Efficient U-Factor and SHGC thresholds in OKNA Windows & Doors Mfg PW810 Picture Window, usually requiring triple-pane or upgraded Low-E coatings.

### What 2026 federal tax credit and Lead RRP rules apply to PW810 Picture Window?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### Where are NFRC and IGCC identification marks located on PW810 Picture Window?

Match the NFRC thermal sticker for code OKW and line OKW-K-28 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for OKNA Windows & Doors Mfg PW810 Picture Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)