description: "Paradigm Window Solutions 8361 Fixed Casement (PWS-A-16, Picture Window, Vinyl): U-Factor 0.12-0.32, SHGC 0.15-0.51, 648 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC PWS · Product Line PWS-A-16 ENERGY STAR Most Efficient Eligible

# Paradigm Window Solutions — 8361 Fixed Casement · Picture Window

Positioning #19/1,352 in certified Window, Paradigm Window Solutions 8361 Fixed Casement pairs Vinyl frame construction with 648 glazing options rated between 0.15 and 0.51 SHGC across Northern, North-Central, South-Central, Southern. Across 11 certified Paradigm Window Solutions product families, its thermal resistance spans 0.12 to 0.32 U-Factor and the line includes 153 ENERGY STAR Most Efficient packages (23.6% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.12

- **SHGC Range** : 0.15-0.51

- **Certified Options** : 648

- **Category Standing** : #19 of 1,352

## How does Paradigm Window Solutions 8361 Fixed Casement compare thermally against Window peers?

Paradigm Window Solutions 8361 Fixed Casement achieves a 0.12 thermal floor across Window lines, placing #19 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Paradigm Window Solutions 8361 Fixed Casement at rank #19 of 1,352 (tied with 16 others at 0.12, more insulating than 97.4% of Window lines, top 2.6%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.15-0.51 band.

Mapping NFRC SHGC values (0.15 to 0.51) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 153 configurations meet ENERGY STAR Most Efficient criteria while 333 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 72.0 BTU/hr (-45.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2026-09-08.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 648 certified glazing combinations for 8361 Fixed Casement (NFRC PWS) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 333 packages (108 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 484 packages (124 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 155 packages (41 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 193 packages (60 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.12 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Euroline Windows Inc.** — Energeto Neo 76 Small Picture Window](https://ela-ecolandscapingassn.org/windows/models/euroline-windows-inc-energeto-neo-76-small-picture-window-413022/) | Vinyl | 0.12 | 0.16 | 1,028 |
| [**Slocomb Windows and Doors, Inc** — 400/500 Series Picture Window](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-400-500-series-picture-window-414097/) | Vinyl | 0.12 | 0.15 | 157 |
| [**Alpen HPP, LLC dba Alpen High Performance Products** — Tyrol Tilt Turn](https://ela-ecolandscapingassn.org/windows/models/alpen-hpp-llc-dba-alpen-high-performance-products-tyrol-tilt-turn-41/) | Vinyl | 0.12 | 0.15 | 120 |
| [**Innotech Windows & Doors Inc.** — Defender 88PH+ XI Fixed](https://ela-ecolandscapingassn.org/windows/models/innotech-windows-doors-inc-defender-88ph-xi-fixed-413335/) | Vinyl | 0.12 | 0.14 | 5,838 |
| [**Innotech Windows & Doors Inc.** — Defender 88PH+ XI Dual Action](https://ela-ecolandscapingassn.org/windows/models/innotech-windows-doors-inc-defender-88ph-xi-dual-action-413336/) | Vinyl | 0.12 | 0.12 | 5,850 |

## What other certified series does Paradigm Window Solutions produce?

Compare other active Paradigm Window Solutions certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Casement WindowsMin U 0.16

### [8351 Casement](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-8351-casement-413973/)

U-Factor 0.16–0.32 · 2,533 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-8351-casement-413973/)

Awning (Projected)Min U 0.16

### [8352 Awning](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-8352-awning-413974/)

U-Factor 0.16–0.32 · 2,446 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-8352-awning-413974/)

Double SliderMin U 0.18

### [8341 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-8341-horizontal-slider-413972/)

U-Factor 0.18–0.32 · 386 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-8341-horizontal-slider-413972/)

Picture WindowMin U 0.18

### [8378 Beveled Picture Window](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-8378-beveled-picture-window-413976/)

U-Factor 0.18–0.26 · 345 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-8378-beveled-picture-window-413976/)

Picture WindowMin U 0.23

### [500/5000 Picture Window](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-500-5000-picture-window-413980/)

U-Factor 0.23–0.26 · 37 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-500-5000-picture-window-413980/)

Double HungMin U 0.23

### [8321 Double Hung](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-8321-double-hung-413970/)

U-Factor 0.23–0.29 · 76 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-8321-double-hung-413970/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Paradigm Window Solutions 8361 Fixed Casement appear below.

### How well does 8361 Fixed Casement by Paradigm Window Solutions insulate relative to Window benchmarks?

Paradigm Window Solutions 8361 Fixed Casement spans 648 certified configurations with U-Factors between 0.12 and 0.32 and SHGC values from 0.15 to 0.51. Ranked #19 of 1,352 Window families, it carries 153 Most Efficient options.

### Does Paradigm Window Solutions 8361 Fixed Casement qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 333 8361 Fixed Casement packages (U floor 0.12, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

### How do you calculate winter heat conduction for Paradigm Window Solutions 8361 Fixed Casement?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 72.0 BTU/hr on 8361 Fixed Casement's lowest-U package (0.12), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### What homeowner profiles are a poor match for Paradigm Window Solutions 8361 Fixed Casement?

Skip 8361 Fixed Casement if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 8361 Fixed Casement options exceeding U 0.22.

### Can you install Paradigm Window Solutions 8361 Fixed Casement in Southern or South-Central zones?

Exactly 193 8361 Fixed Casement options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.15 rather than higher 0.51 glass.

### Which package tier in 8361 Fixed Casement holds Most Efficient recognition?

EPA lists 153 Most Efficient options (23.6% share) inside Paradigm Window Solutions 8361 Fixed Casement, out of 648 total Version 7.0 entries.

### How do the 25C sunset and pre-1978 Lead RRP rules affect 8361 Fixed Casement?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Paradigm Window Solutions upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How do building inspectors verify 8361 Fixed Casement glass specs on job sites?

Verify NFRC ID PWS and series PWS-A-16 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Paradigm Window Solutions 8361 Fixed Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)