title: "Pella Impervia Fixed Specs (U 0.22) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/pella-corporation-impervia-fixed-413889/
description: "Pella Impervia Fixed (PEL-N-104, Picture Window, Fiberglass): U-Factor 0.22-0.32, SHGC 0.13-0.50, 602 options across 4 ENERGY STAR zones. Verified against."
---

Window · Fiberglass Frame NFRC PEL · Product Line PEL-N-104 ENERGY STAR Most Efficient Eligible

# Pella Corporation — Impervia Fixed · Picture Window

Pella Corporation Impervia Fixed is a Picture Window assembly with a Fiberglass frame that reaches a minimum U-Factor of 0.22 across 602 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #831 of 1,352 in Window, its thermal floor is 0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.13 to 0.50.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.22

- **SHGC Range** : 0.13-0.50

- **Certified Options** : 602

- **Category Standing** : #831 of 1,352

## How does Pella Corporation Impervia Fixed compare thermally against Window peers?

Pella Corporation Impervia Fixed achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Impervia Fixed spans 602 NFRC test records (PEL), ranking #831 of 1,352 Window families (tied with 104 others at 0.22, more insulating than 30.8% of Window lines). Its 0.22 thermal floor compares at +0.03 against the Fiberglass median (0.19).

Climate coverage for Pella Corporation Impervia Fixed spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 12 configurations meet ENERGY STAR Most Efficient criteria while 78 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-05-02 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 132.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 602 certified glazing combinations for Impervia Fixed (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 78 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 212 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 233 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 442 packages (12 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Marvin** — Essential Direct Glaze](https://ela-ecolandscapingassn.org/windows/models/marvin-essential-direct-glaze-413579/) | Fiberglass | 0.22 | 0.19 | 316 |
| [**Windsor Windows and Doors** — Next Dimension Casement Picture](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-casement-picture-414386/) | Vinyl | 0.22 | 0.16 | 598 |
| [**Windsor Windows and Doors** — Pinnacle Primed Casement](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-primed-casement-414396/) | Other | 0.22 | 0.14 | 610 |
| [**Windsor Windows and Doors** — Pinnacle Prime Double Hung Fixed](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-prime-double-hung-fixed-414405/) | Wood | 0.22 | 0.14 | 631 |
| [**Soft-Lite, LLC** — Classic Plus DSL10P Slider](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-classic-plus-dsl10p-slider-414114/) | Vinyl | 0.22 | 0.15 | 632 |

## What other certified series does Pella Corporation produce?

Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Swinging Entry Door (Single)Min U 0.13

### [Pella Entry Doors - Wood Edge Steel Door](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-wood-edge-steel-door-413917/)

U-Factor 0.13–0.28 · 76,045 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-wood-edge-steel-door-413917/)

Picture WindowMin U 0.14

### [250 Series / Power Symphony Fixed](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-fixed-413894/)

U-Factor 0.14–0.32 · 266 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-fixed-413894/)

Picture WindowMin U 0.15

### [250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-cws-comfort-shield-burri/)

U-Factor 0.15–0.32 · 144 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-cws-comfort-shield-burri/)

Picture WindowMin U 0.15

### [Architect Wood Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-architect-wood-fixed-casement-413886/)

U-Factor 0.15–0.32 · 2,468 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-architect-wood-fixed-casement-413886/)

Swinging Entry Door (Single)Min U 0.15

### [Pella Entry Doors - Fiberglass Skin Door](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-door-413915/)

U-Factor 0.15–0.28 · 242,982 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-door-413915/)

SideliteMin U 0.15

### [Pella Entry Doors - Fiberglass Skin Sidelite](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-sidelite-413916/)

U-Factor 0.15–0.28 · 319,127 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-sidelite-413916/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation Impervia Fixed appear below.

### Where does Pella Corporation Impervia Fixed stand thermally among ENERGY STAR Window lines?

Across 602 tested NFRC glazing configurations, Pella Corporation Impervia Fixed with Fiberglass framing and Fixed Window (FIXD) style reaches a 0.22 minimum U-Factor and 0.13-0.50 SHGC band. It places #831 among 1,352 Window series—more insulating than 30.8%.

### Can homeowners install Impervia Fixed in cold Northern ENERGY STAR counties?

Cold-climate buyers get 78 compliant Northern packages inside Impervia Fixed, reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

### What BTU/hr heat transfer results from Impervia Fixed's 0.22 minimum U-Factor?

At U 0.22, a standard 3x5 ft (15 sq ft) Impervia Fixed opening transfers 132.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +0.0 BTU/hr difference.

### When should a buyer skip Pella Corporation Impervia Fixed and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Impervia Fixed options exceeding U 0.22. Verify whether your municipal code restricts Fiberglass frames in wildfire or historic zones.

### What Southern ENERGY STAR v7.0 options exist in Impervia Fixed?

Exactly 442 Impervia Fixed options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.13 rather than higher 0.50 glass.

### What glazing share inside Impervia Fixed qualifies as Most Efficient?

EPA lists 12 Most Efficient options (2.0% share) inside Pella Corporation Impervia Fixed, out of 602 total Version 7.0 entries.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Impervia Fixed?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Impervia Fixed installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How do building inspectors verify Impervia Fixed glass specs on job sites?

Verify NFRC ID PEL and series PEL-N-104 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Pella Corporation Impervia Fixed come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)