Window · Fiberglass Frame NFRC PEL · Product Line PEL-N-102

# Pella Corporation — Impervia Single Hung · Single Hung

Pella Corporation Impervia Single Hung is a Single Hung assembly with a Fiberglass frame that reaches a minimum U-Factor of 0.23 across 574 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #936 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.12 to 0.48.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.12-0.48

- **Certified Options** : 574

- **Category Standing** : #936 of 1,352

## How does Pella Corporation Impervia Single Hung compare thermally against Window peers?

Pella Corporation Impervia Single Hung achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Impervia Single Hung spans 574 NFRC test records (PEL), ranking #936 of 1,352 Window families (tied with 97 others at 0.23, more insulating than 23.6% of Window lines). Its 0.23 thermal floor compares at +0.04 against the Fiberglass median (0.19).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 17 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors PEL to 2024-05-02 certification (FENSTAR issued 2018-02-20). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 138.0 BTU/hr conductive loss (+4.5% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 574 certified glazing combinations for Impervia Single Hung (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 17 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 72 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 213 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 517 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Marvin** — Essential Casement Picture](https://ela-ecolandscapingassn.org/windows/models/marvin-essential-casement-picture-413607/) | Fiberglass | 0.23 | 0.18 | 316 |
| [**Marvin** — Essential Double Hung Picture](https://ela-ecolandscapingassn.org/windows/models/marvin-essential-double-hung-picture-413602/) | Fiberglass | 0.23 | 0.20 | 101 |
| [**Marvin** — Vivid Double Hung Picture / Insert Picture](https://ela-ecolandscapingassn.org/windows/models/marvin-vivid-double-hung-picture-insert-picture-413659/) | Fiberglass | 0.23 | 0.06 | 1,087 |
| [**Milgard Manufacturing, Inc.** — 3644/3664 Panel Set Transom Inswing](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-3644-3664-panel-set-transom-inswing-413753/) | Fiberglass | 0.23 | 0.09 | 2,958 |
| [**Milgard Manufacturing, Inc.** — 3647/3667 Outswing Panel Glazed Transom](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-3647-3667-outswing-panel-glazed-transom-41/) | Fiberglass | 0.23 | 0.09 | 3,017 |

## What other certified series does Pella Corporation produce?

Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Swinging Entry Door (Single)Min U 0.13

### [Pella Entry Doors - Wood Edge Steel Door](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-wood-edge-steel-door-413917/)

U-Factor 0.13–0.28 · 76,045 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-wood-edge-steel-door-413917/)

Picture WindowMin U 0.14

### [250 Series / Power Symphony Fixed](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-fixed-413894/)

U-Factor 0.14–0.32 · 266 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-fixed-413894/)

Picture WindowMin U 0.15

### [250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-cws-comfort-shield-burri/)

U-Factor 0.15–0.32 · 144 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-cws-comfort-shield-burri/)

Picture WindowMin U 0.15

### [Architect Wood Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-architect-wood-fixed-casement-413886/)

U-Factor 0.15–0.32 · 2,468 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-architect-wood-fixed-casement-413886/)

Swinging Entry Door (Single)Min U 0.15

### [Pella Entry Doors - Fiberglass Skin Door](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-door-413915/)

U-Factor 0.15–0.28 · 242,982 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-door-413915/)

SideliteMin U 0.15

### [Pella Entry Doors - Fiberglass Skin Sidelite](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-sidelite-413916/)

U-Factor 0.15–0.28 · 319,127 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-sidelite-413916/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation Impervia Single Hung appear below.

### How efficient is Pella Corporation Impervia Single Hung compared with peer Window models?

Built with Fiberglass framing in Single-Hung (VSSH) style, Pella Corporation Impervia Single Hung offers 574 Version 7.0 configurations from U 0.23 up to 0.32, posting +0.03 against the Window median of 0.20 with 0 Most Efficient picks.

### Does Pella Corporation Impervia Single Hung qualify for the ENERGY STAR Northern Zone?

With a 0.23 minimum U-Factor, Pella Corporation Impervia Single Hung cannot satisfy prescriptive <= 0.22 Northern targets, yet 17 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

### How much winter heat loss does Impervia Single Hung conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.23 U-Factor yields 138.0 BTU/hr conductive transfer (+4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What homeowner profiles are a poor match for Pella Corporation Impervia Single Hung?

Do not specify Impervia Single Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Impervia Single Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### How many Impervia Single Hung glazing packages pass Southern solar-heat rules?

Exactly 517 Impervia Single Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.12 rather than higher 0.48 glass.

### Which package tier in Impervia Single Hung holds Most Efficient recognition?

No. Zero of the 574 configurations in Pella Corporation Impervia Single Hung hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

### Do 2026 Impervia Single Hung installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How do you cross-check NFRC PEL and product line PEL-N-102 on delivery?

Inspectors match the temporary NFRC sticker (U 0.23-0.32, SHGC 0.12-0.48) against permit drawings for line PEL-N-102. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Pella Corporation Impervia Single Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)