---
title: "Pella Impervia Sliding Window Specs (U 0.23) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/pella-corporation-impervia-sliding-window-413888/
description: "Pella Impervia Sliding Window (PEL-N-103, Single Slider, Fiberglass): U-Factor 0.23-0.32, SHGC 0.12-0.48, 670 options across 4 ENERGY STAR zones."
---

Window · Fiberglass Frame NFRC PEL · Product Line PEL-N-103

# Pella Corporation — Impervia Sliding Window · Single Slider

With a minimum U-Factor of 0.23—+0.03 compared against the 0.20 Window median—Pella Corporation Impervia Sliding Window spans 670 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code PEL, the Fiberglass assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.12 and 0.48.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.12-0.48

- **Certified Options** : 670

- **Category Standing** : #936 of 1,352

## How does Pella Corporation Impervia Sliding Window compare thermally against Window peers?

Pella Corporation Impervia Sliding Window achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Pella Corporation Impervia Sliding Window standing at #936 of 1,352 certified Window product series, tied with 97 others at 0.23, more insulating than 23.6% of Window lines. Comparing Fiberglass profiles alone (median 0.19) shows +0.04 before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 20 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2018-02-20 and v7.0 data certification on 2024-05-02. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.23 conducts 138.0 BTU/hr (+6.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 670 certified glazing combinations for Impervia Sliding Window (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 20 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 83 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 231 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 605 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Marvin** — Essential Casement Picture](https://ela-ecolandscapingassn.org/windows/models/marvin-essential-casement-picture-413607/) | Fiberglass | 0.23 | 0.18 | 316 |
| [**Marvin** — Vivid Double Hung Picture / Insert Picture](https://ela-ecolandscapingassn.org/windows/models/marvin-vivid-double-hung-picture-insert-picture-413659/) | Fiberglass | 0.23 | 0.06 | 1,087 |
| [**Marvin** — Essential Double Hung Picture](https://ela-ecolandscapingassn.org/windows/models/marvin-essential-double-hung-picture-413602/) | Fiberglass | 0.23 | 0.20 | 101 |
| [**Milgard Manufacturing, Inc.** — 3644/3664 Panel Set Transom Inswing](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-3644-3664-panel-set-transom-inswing-413753/) | Fiberglass | 0.23 | 0.09 | 2,958 |
| [**Milgard Manufacturing, Inc.** — 3647/3667 Outswing Panel Glazed Transom](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-3647-3667-outswing-panel-glazed-transom-41/) | Fiberglass | 0.23 | 0.09 | 3,017 |

## What other certified series does Pella Corporation produce?

Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Swinging Entry Door (Single)Min U 0.13

### [Pella Entry Doors - Wood Edge Steel Door](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-wood-edge-steel-door-413917/)

U-Factor 0.13–0.28 · 76,045 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-wood-edge-steel-door-413917/)

Picture WindowMin U 0.14

### [250 Series / Power Symphony Fixed](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-fixed-413894/)

U-Factor 0.14–0.32 · 266 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-fixed-413894/)

Picture WindowMin U 0.15

### [250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-cws-comfort-shield-burri/)

U-Factor 0.15–0.32 · 144 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-cws-comfort-shield-burri/)

Picture WindowMin U 0.15

### [Architect Wood Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-architect-wood-fixed-casement-413886/)

U-Factor 0.15–0.32 · 2,468 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-architect-wood-fixed-casement-413886/)

Swinging Entry Door (Single)Min U 0.15

### [Pella Entry Doors - Fiberglass Skin Door](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-door-413915/)

U-Factor 0.15–0.28 · 242,982 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-door-413915/)

SideliteMin U 0.15

### [Pella Entry Doors - Fiberglass Skin Sidelite](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-sidelite-413916/)

U-Factor 0.15–0.28 · 319,127 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-sidelite-413916/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation Impervia Sliding Window appear below.

### What U-Factor and SHGC range does Pella Corporation Impervia Sliding Window achieve?

EPA ENERGY STAR v7.0 records 670 configurations for Pella Corporation Impervia Sliding Window covering Northern, North-Central, South-Central, Southern, dropping down to U 0.23 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

### Does Pella Corporation Impervia Sliding Window qualify for the ENERGY STAR Northern Zone?

Because Impervia Sliding Window starts at 0.23 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 20 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

### What conductive BTU/hr difference separates Impervia Sliding Window from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.23 U-Factor yields 138.0 BTU/hr conductive transfer (+4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What homeowner profiles are a poor match for Pella Corporation Impervia Sliding Window?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Impervia Sliding Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Can you install Pella Corporation Impervia Sliding Window in Southern or South-Central zones?

Yes, Impervia Sliding Window holds 605 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.12 SHGC in cooling climates.

### Are all 670 Impervia Sliding Window configurations ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 670 Impervia Sliding Window options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Impervia Sliding Window?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How can homeowners confirm delivered Pella Corporation Impervia Sliding Window units match permits?

Verify NFRC ID PEL and series PEL-N-103 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Pella Corporation Impervia Sliding Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
