---
title: "Pella Pella Architect Clad Awning Specs (U 0.19)"
url: https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-architect-clad-awning-413883/
description: "Pella Pella Architect Clad Awning (PEL-N-30, Awning (Projected), Wood): U-Factor 0.19-0.32, SHGC 0.11-0.46, 547 options across 4 ENERGY STAR zones."
---

Window · Wood Frame NFRC PEL · Product Line PEL-N-30 ENERGY STAR Most Efficient Eligible

# Pella Corporation — Pella Architect Clad Awning · Awning (Projected)

Across 39 Pella Corporation certified families, Pella Architect Clad Awning supplies 547 Awning, Projected configurations starting at 0.19 U-Factor and 0.11 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.46 SHGC. Its thermal floor ranks #564 of 1,352 category entries—0.01 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.19

- **SHGC Range** : 0.11-0.46

- **Certified Options** : 547

- **Category Standing** : #564 of 1,352

## How does Pella Corporation Pella Architect Clad Awning compare thermally against Window peers?

Pella Corporation Pella Architect Clad Awning achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Pella Corporation Pella Architect Clad Awning standing at #564 of 1,352 certified Window product series, tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%. Comparing Wood profiles alone (median 0.21) shows -0.02 before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 36 configurations meet ENERGY STAR Most Efficient criteria while 65 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-12-17 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 114.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 547 certified glazing combinations for Pella Architect Clad Awning (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 65 packages (15 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 91 packages (21 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 181 packages (14 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 499 packages (27 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Lincoln Wood Products, Inc.** — Clad Casement Studio (Transom) - Crank-Out & Push-Out](https://ela-ecolandscapingassn.org/windows/models/lincoln-wood-products-inc-clad-casement-studio-transom-crank-out-pus/) | Wood | 0.19 | 0.16 | 598 |
| [**Lepage Millwork** — Wood Awning C-100](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-wood-awning-c-100-413517/) | Wood | 0.19 | 0.15 | 281 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra Awning](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-awning-413458/) | Wood | 0.19 | 0.09 | 908 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra Series Swing Door Transom](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-series-swing-door-transom-4134/) | Wood | 0.19 | 0.09 | 2,084 |
| [**Sierra Pacific Windows** — Alum Clad Bi-Fold OS Window](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-alum-clad-bi-fold-os-window-414066/) | Wood | 0.19 | 0.08 | 2,117 |

## What other certified series does Pella Corporation produce?

Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Swinging Entry Door (Single)Min U 0.13

### [Pella Entry Doors - Wood Edge Steel Door](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-wood-edge-steel-door-413917/)

U-Factor 0.13–0.28 · 76,045 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-wood-edge-steel-door-413917/)

Picture WindowMin U 0.14

### [250 Series / Power Symphony Fixed](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-fixed-413894/)

U-Factor 0.14–0.32 · 266 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-fixed-413894/)

Picture WindowMin U 0.15

### [250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-cws-comfort-shield-burri/)

U-Factor 0.15–0.32 · 144 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-cws-comfort-shield-burri/)

Picture WindowMin U 0.15

### [Architect Wood Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-architect-wood-fixed-casement-413886/)

U-Factor 0.15–0.32 · 2,468 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-architect-wood-fixed-casement-413886/)

Swinging Entry Door (Single)Min U 0.15

### [Pella Entry Doors - Fiberglass Skin Door](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-door-413915/)

U-Factor 0.15–0.28 · 242,982 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-door-413915/)

SideliteMin U 0.15

### [Pella Entry Doors - Fiberglass Skin Sidelite](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-sidelite-413916/)

U-Factor 0.15–0.28 · 319,127 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-sidelite-413916/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation Pella Architect Clad Awning appear below.

### How efficient is Pella Corporation Pella Architect Clad Awning compared with peer Window models?

Across 547 tested NFRC glazing configurations, Pella Corporation Pella Architect Clad Awning with Wood framing and Projected Awning (PRAW) style reaches a 0.19 minimum U-Factor and 0.11-0.46 SHGC band. It places #564 among 1,352 Window series—top 49.6%.

### Does Pella Corporation Pella Architect Clad Awning qualify for the ENERGY STAR Northern Zone?

Pella Corporation Pella Architect Clad Awning supplies 65 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

### What conductive BTU/hr difference separates Pella Architect Clad Awning from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Pella Architect Clad Awning at U 0.19 conducts 114.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### What are the practical limitations of specifying Pella Architect Clad Awning?

Skip Pella Architect Clad Awning if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pella Architect Clad Awning options exceeding U 0.22.

### Is Pella Architect Clad Awning suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 499 Southern-approved options within Pella Architect Clad Awning spanning SHGC down to 0.11. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### How many Pella Corporation Pella Architect Clad Awning variants earn ENERGY STAR Most Efficient?

Only 36 options out of 547 (6.6%) meet tighter Most Efficient U-Factor and SHGC thresholds in Pella Corporation Pella Architect Clad Awning, usually requiring triple-pane or upgraded Low-E coatings.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Pella Architect Clad Awning?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Pella Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How do building inspectors verify Pella Architect Clad Awning glass specs on job sites?

Match the NFRC thermal sticker for code PEL and line PEL-N-30 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Pella Corporation Pella Architect Clad Awning come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
