# Pella Corporation — Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 · Double Hung

With a minimum U-Factor of 0.25—+0.05 compared against the 0.20 Window median—Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 spans 168 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code PEL, the Other / Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.12 and 0.49.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.25

- **SHGC Range** : 0.12-0.49

- **Certified Options** : 168

- **Category Standing** : #1,174 of 1,352

## How does Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 compare thermally against Window peers?

Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Other / Wood cohort (0.18 median U-Factor), Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 reaches 0.25 on its lowest-conductivity package — #6 of 6 in Other / Wood, lowest-ranked of 6 Other / Wood lines (+0.07 vs Other / Wood peers). Pairing NFRC ID PEL across multi-pane fills shifts U-Factor from 0.32 down toward 0.25.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 4 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.25 U-Factor yields 150.0 BTU/hr transfer (+18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2025-04-24 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 168 certified glazing combinations for Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 4 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 8 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 46 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 160 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Anlin Industries** — Monte Verde Horizontal Sliding](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-monte-verde-horizontal-sliding-413037/) | Vinyl | 0.25 | 0.13 | 173 |
| [**Anlin Industries** — Monte Verde Single Hung](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-monte-verde-single-hung-413036/) | Vinyl | 0.25 | 0.13 | 179 |
| [**Custom Window Systems, Inc.** — PW-8300 Fixed](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-pw-8300-fixed-413140/) | Vinyl | 0.25 | 0.15 | 150 |
| [**Weather Shield Mfg., Inc.** — 8120/1104/1105 Double Hung](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8120-1104-1105-double-hung-414355/) | Wood | 0.25 | 0.11 | 199 |
| [**Burris Windows** — TectView AC Single Hung](https://ela-ecolandscapingassn.org/windows/models/burris-windows-tectview-ac-single-hung-413092/) | Vinyl | 0.25 | 0.12 | 135 |

## What other certified series does Pella Corporation produce?

Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Swinging Entry Door (Single)Min U 0.13

### [Pella Entry Doors - Wood Edge Steel Door](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-wood-edge-steel-door-413917/)

U-Factor 0.13–0.28 · 76,045 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-wood-edge-steel-door-413917/)

Picture WindowMin U 0.14

### [250 Series / Power Symphony Fixed](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-fixed-413894/)

U-Factor 0.14–0.32 · 266 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-fixed-413894/)

Picture WindowMin U 0.15

### [250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-cws-comfort-shield-burri/)

U-Factor 0.15–0.32 · 144 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-cws-comfort-shield-burri/)

Picture WindowMin U 0.15

### [Architect Wood Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-architect-wood-fixed-casement-413886/)

U-Factor 0.15–0.32 · 2,468 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-architect-wood-fixed-casement-413886/)

Swinging Entry Door (Single)Min U 0.15

### [Pella Entry Doors - Fiberglass Skin Door](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-door-413915/)

U-Factor 0.15–0.28 · 242,982 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-door-413915/)

SideliteMin U 0.15

### [Pella Entry Doors - Fiberglass Skin Sidelite](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-sidelite-413916/)

U-Factor 0.15–0.28 · 319,127 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-sidelite-413916/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 appear below.

### What thermal performance numbers separate Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 from peers?

Built with Other / Wood framing in Double-Hung (VSDH) style, Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 offers 168 Version 7.0 configurations from U 0.25 up to 0.32, posting +0.05 against the Window median of 0.20 with 0 Most Efficient picks.

### Can homeowners install Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 in cold Northern ENERGY STAR counties?

Northern qualification on Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.25. Exactly 4 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

### What conductive BTU/hr difference separates Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 at U 0.25 conducts 150.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### Who should NOT choose Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### How many Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 glazing packages pass Southern solar-heat rules?

Yes. 160 Southern-certified options inside Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.49 SHGC on west-facing glass to avoid excess afternoon solar gain.

### How many Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 variants earn ENERGY STAR Most Efficient?

Zero glazing builds inside Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5's 168 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

### What 2026 federal tax credit and Lead RRP rules apply to Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Pella Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How do building inspectors verify Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 glass specs on job sites?

Verify NFRC ID PEL and series PEL-N-233 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Pella Corporation Pella Architect Reserve Double Hung - Precision Fit - Clad/Wood - Model 5 come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)