title: "PGT Industries AW5440/5540 Specs (U 0.17) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/pgt-industries-aw5440-5540-413926/
description: "PGT Industries AW5440/5540 (PGT-A-236, Awning (Projected), Vinyl): U-Factor 0.17-0.32, SHGC 0.08-0.37, 16848 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC PGT · Product Line PGT-A-236 ENERGY STAR Most Efficient Eligible

# PGT Industries — AW5440/5540 · Awning (Projected)

Positioning #362/1,352 in certified Window, PGT Industries AW5440/5540 pairs Vinyl frame construction with 16,848 glazing options rated between 0.08 and 0.37 SHGC across Northern, North-Central, South-Central, Southern. Across 8 certified PGT Industries product families, its thermal resistance spans 0.17 to 0.32 U-Factor and the line includes 129 ENERGY STAR Most Efficient packages (0.8% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.08-0.37

- **Certified Options** : 16,848

- **Category Standing** : #362 of 1,352

## How does PGT Industries AW5440/5540 compare thermally against Window peers?

PGT Industries AW5440/5540 achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), AW5440/5540 is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.32.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 129 configurations meet ENERGY STAR Most Efficient criteria while 66 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2025-07-31 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 16,848 certified glazing combinations for AW5440/5540 (NFRC PGT) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 66 packages (32 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 217 packages (72 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 4,144 packages (64 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 16,827 packages (121 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**MI Windows and Doors, LLC** — 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-1555-1556-polyvinyl-chloride-pvc-double-hun/) | Vinyl | 0.17 | 0.06 | 17,618 |
| [**Simonton Building Products, Inc. - Simonton Windows** — 325-325 CA](https://ela-ecolandscapingassn.org/windows/models/simonton-building-products-inc-simonton-windows-325-325-ca-414043/) | Vinyl | 0.17 | 0.09 | 13,628 |
| [**Simonton Building Products, Inc. - Simonton Windows** — 325-325 AW](https://ela-ecolandscapingassn.org/windows/models/simonton-building-products-inc-simonton-windows-325-325-aw-414044/) | Vinyl | 0.17 | 0.09 | 13,343 |
| [**Simonton Building Products, Inc. - Simonton Windows** — 325-325 Double Slider](https://ela-ecolandscapingassn.org/windows/models/simonton-building-products-inc-simonton-windows-325-325-double-slide/) | Vinyl | 0.17 | 0.08 | 21,756 |
| [**Quaker Window Products** — V300 Casement](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-casement-413981/) | Vinyl | 0.17 | 0.09 | 11,114 |

## What other certified series does PGT Industries produce?

Compare other active PGT Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [PW5420/5520](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-pw5420-5520-413922/)

U-Factor 0.13–0.32 · 23,690 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-pw5420-5520-413922/)

Picture WindowMin U 0.15

### [PW5440/5540](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-pw5440-5540-413923/)

U-Factor 0.15–0.32 · 25,346 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-pw5440-5540-413923/)

Casement WindowsMin U 0.17

### [CA5440/5540](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-ca5440-5540-413925/)

U-Factor 0.17–0.32 · 17,693 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-ca5440-5540-413925/)

Single SliderMin U 0.17

### [HR5410/5510](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-hr5410-5510-413921/)

U-Factor 0.17–0.32 · 8,277 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-hr5410-5510-413921/)

Single HungMin U 0.17

### [SH5400/5500](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-sh5400-5500-413924/)

U-Factor 0.17–0.32 · 9,241 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-sh5400-5500-413924/)

Double HungMin U 0.18

### [DH5460/5560](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-dh5460-5560-413920/)

U-Factor 0.18–0.32 · 6,757 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-dh5460-5560-413920/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to PGT Industries AW5440/5540 appear below.

### How well does AW5440/5540 by PGT Industries insulate relative to Window benchmarks?

Across 16,848 tested NFRC glazing configurations, PGT Industries AW5440/5540 with Vinyl framing and Projected Awning (PRAW) style reaches a 0.17 minimum U-Factor and 0.08-0.37 SHGC band. It places #362 among 1,352 Window series—top 35.2%.

### Which glazing options in PGT Industries AW5440/5540 meet Northern climate limits?

PGT Industries AW5440/5540 supplies 66 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

### How does a 3x5 ft AW5440/5540 window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), AW5440/5540 at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### Which situations make AW5440/5540 the wrong window or door choice?

Do not specify AW5440/5540 without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on AW5440/5540 options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does AW5440/5540 meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 16,827 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside PGT Industries AW5440/5540, while total line SHGC reaches 0.37 in colder packages.

### Are all 16,848 AW5440/5540 configurations ENERGY STAR Most Efficient?

Only 129 options out of 16,848 (0.8%) meet tighter Most Efficient U-Factor and SHGC thresholds in PGT Industries AW5440/5540, usually requiring triple-pane or upgraded Low-E coatings.

### Can homeowners claim Form 5695 credits on PGT Industries AW5440/5540 in 2026?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current AW5440/5540 retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How do building inspectors verify AW5440/5540 glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line PGT-A-236 and NFRC ID PGT before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for PGT Industries AW5440/5540 come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)