---
title: "PGT Industries HR5410/5510 Specs (U 0.17) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/pgt-industries-hr5410-5510-413921/
description: "PGT Industries HR5410/5510 (PGT-A-231, Single Slider, Vinyl): U-Factor 0.17-0.32, SHGC 0.08-0.43, 8277 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC PGT · Product Line PGT-A-231 ENERGY STAR Most Efficient Eligible

# PGT Industries — HR5410/5510 · Single Slider

With a minimum U-Factor of 0.17—-0.03 compared against the 0.20 Window median—PGT Industries HR5410/5510 spans 8,277 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code PGT, the Vinyl assembly includes 110 ENERGY STAR Most Efficient packages (1.3% of line) and offers SHGC packages between 0.08 and 0.43.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.08-0.43

- **Certified Options** : 8,277

- **Category Standing** : #362 of 1,352

## How does PGT Industries HR5410/5510 compare thermally against Window peers?

PGT Industries HR5410/5510 achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places PGT Industries HR5410/5510 at rank #362 of 1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.08-0.43 band.

Regional qualification covers Northern, North-Central, South-Central, Southern. 110 configurations meet ENERGY STAR Most Efficient criteria while 111 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2025-07-31 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 102.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 8,277 certified glazing combinations for HR5410/5510 (NFRC PGT) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 111 packages (32 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 183 packages (68 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 894 packages (46 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 8,203 packages (84 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Vinylmax LLC** — DHA4 Double Hung](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-dha4-double-hung-414264/) | Vinyl | 0.17 | 0.14 | 7,745 |
| [**Wincore Window Company, LLC** — 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-5400-5400s-7700-8400-8800-9900-series-vin/) | Vinyl | 0.17 | 0.08 | 6,278 |
| [**Wincore Window Company, LLC** — 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-5400-5400s-7700-8400-8800-9900-series-vin-414335/) | Vinyl | 0.17 | 0.08 | 6,256 |
| [**Wincore Window Company, LLC** — 7700, 9900 Basement Window](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-7700-9900-basement-window-414340/) | Vinyl | 0.17 | 0.08 | 6,256 |
| [**Quaker Window Products** — V300 Awning](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-awning-413982/) | Vinyl | 0.17 | 0.09 | 11,097 |

## What other certified series does PGT Industries produce?

Compare other active PGT Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [PW5420/5520](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-pw5420-5520-413922/)

U-Factor 0.13–0.32 · 23,690 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-pw5420-5520-413922/)

Picture WindowMin U 0.15

### [PW5440/5540](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-pw5440-5540-413923/)

U-Factor 0.15–0.32 · 25,346 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-pw5440-5540-413923/)

Awning (Projected)Min U 0.17

### [AW5440/5540](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-aw5440-5540-413926/)

U-Factor 0.17–0.32 · 16,848 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-aw5440-5540-413926/)

Casement WindowsMin U 0.17

### [CA5440/5540](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-ca5440-5540-413925/)

U-Factor 0.17–0.32 · 17,693 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-ca5440-5540-413925/)

Single HungMin U 0.17

### [SH5400/5500](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-sh5400-5500-413924/)

U-Factor 0.17–0.32 · 9,241 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-sh5400-5500-413924/)

Double HungMin U 0.18

### [DH5460/5560](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-dh5460-5560-413920/)

U-Factor 0.18–0.32 · 6,757 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-dh5460-5560-413920/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to PGT Industries HR5410/5510 appear below.

### What U-Factor and SHGC range does PGT Industries HR5410/5510 achieve?

Across 8,277 tested NFRC glazing configurations, PGT Industries HR5410/5510 with Vinyl framing and Horizontal Slider (HSOX) style reaches a 0.17 minimum U-Factor and 0.08-0.43 SHGC band. It places #362 among 1,352 Window series—top 35.2%.

### How does PGT Industries HR5410/5510 satisfy Version 7.0 Northern criteria?

Yes. 111 packages in PGT Industries HR5410/5510 clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

### How much winter heat loss does HR5410/5510 conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 102.0 BTU/hr on HR5410/5510's lowest-U package (0.17), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### What homeowner profiles are a poor match for PGT Industries HR5410/5510?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on HR5410/5510 options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

### What Southern ENERGY STAR v7.0 options exist in HR5410/5510?

Warm-climate homeowners have 8,203 Southern-approved options within HR5410/5510 spanning SHGC down to 0.08. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### How many PGT Industries HR5410/5510 variants earn ENERGY STAR Most Efficient?

Within HR5410/5510, 1.3% (110 of 8,277) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

### Do 2026 HR5410/5510 installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current HR5410/5510 retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### What permanent glass etch marks verify HR5410/5510 after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line PGT-A-231 and NFRC ID PGT before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for PGT Industries HR5410/5510 come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
