Window · Vinyl Frame NFRC PGT · Product Line PGT-A-233 ENERGY STAR Most Efficient Eligible

# PGT Industries — PW5440/5540 · Picture Window

Positioning #136/1,352 in certified Window, PGT Industries PW5440/5540 pairs Vinyl frame construction with 25,346 glazing options rated between 0.07 and 0.44 SHGC across Northern, North-Central, South-Central, Southern. Across 8 certified PGT Industries product families, its thermal resistance spans 0.15 to 0.32 U-Factor and the line includes 279 ENERGY STAR Most Efficient packages (1.1% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.15

- **SHGC Range** : 0.07-0.44

- **Certified Options** : 25,346

- **Category Standing** : #136 of 1,352

## How does PGT Industries PW5440/5540 compare thermally against Window peers?

PGT Industries PW5440/5540 achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), PW5440/5540 reaches 0.15 on its lowest-conductivity package — #89 of 1,009 in Vinyl, tied with 80 others at 0.15, more insulating than 83.3% of Vinyl lines, top 16.7% (-0.04 vs Vinyl peers). Pairing NFRC ID PGT across multi-pane fills shifts U-Factor from 0.32 down toward 0.15.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 279 configurations meet ENERGY STAR Most Efficient criteria while 372 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 90.0 BTU/hr (-31.8% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2025-09-29.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 25,346 certified glazing combinations for PW5440/5540 (NFRC PGT) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 372 packages (63 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 6,627 packages (137 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 12,783 packages (90 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 23,711 packages (225 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Milgard Manufacturing, Inc.** — 8520T2.8530T2.8570T2 Casement](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8520t2-8530t2-8570t2-casement-413771/) | Vinyl | 0.15 | 0.08 | 24,195 |
| [**Milgard Manufacturing, Inc.** — 8420T2.8430T2.8470T2 Awning](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8420t2-8430t2-8470t2-awning-413772/) | Vinyl | 0.15 | 0.08 | 23,678 |
| [**Simonton Building Products, Inc. - Simonton Windows** — 325-325 CA PW (No Hinge)](https://ela-ecolandscapingassn.org/windows/models/simonton-building-products-inc-simonton-windows-325-325-ca-pw-no-hin/) | Vinyl | 0.15 | 0.08 | 19,435 |
| [**Milgard Manufacturing, Inc.** — 8354 Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8354-fixed-413765/) | Vinyl | 0.15 | 0.09 | 16,371 |
| [**Wincore Window Company, LLC** — 5400, 7700 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-5400-7700-casement-picture-window-414336/) | Vinyl | 0.15 | 0.07 | 16,031 |

## What other certified series does PGT Industries produce?

Compare other active PGT Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [PW5420/5520](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-pw5420-5520-413922/)

U-Factor 0.13–0.32 · 23,690 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-pw5420-5520-413922/)

Awning (Projected)Min U 0.17

### [AW5440/5540](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-aw5440-5540-413926/)

U-Factor 0.17–0.32 · 16,848 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-aw5440-5540-413926/)

Casement WindowsMin U 0.17

### [CA5440/5540](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-ca5440-5540-413925/)

U-Factor 0.17–0.32 · 17,693 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-ca5440-5540-413925/)

Single SliderMin U 0.17

### [HR5410/5510](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-hr5410-5510-413921/)

U-Factor 0.17–0.32 · 8,277 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-hr5410-5510-413921/)

Single HungMin U 0.17

### [SH5400/5500](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-sh5400-5500-413924/)

U-Factor 0.17–0.32 · 9,241 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-sh5400-5500-413924/)

Double HungMin U 0.18

### [DH5460/5560](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-dh5460-5560-413920/)

U-Factor 0.18–0.32 · 6,757 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-dh5460-5560-413920/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to PGT Industries PW5440/5540 appear below.

### What U-Factor and SHGC range does PGT Industries PW5440/5540 achieve?

Built with Vinyl framing in Fixed Window (FIXD) style, PGT Industries PW5440/5540 offers 25,346 Version 7.0 configurations from U 0.15 up to 0.32, posting -0.05 against the Window median of 0.20 with 279 Most Efficient picks.

### Is PW5440/5540 approved for Northern Zone heating climates?

Cold-climate buyers get 372 compliant Northern packages inside PW5440/5540, reaching down to U 0.15. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

### What conductive BTU/hr difference separates PW5440/5540 from the 0.22 Northern rule?

Using NFRC PGT U-Factor 0.15, a 15 sq ft Fixed Window (FIXD) assembly conducts 90.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-42.0 BTU/hr margin).

### Who should NOT choose PGT Industries PW5440/5540 for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on PW5440/5540 options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Does PW5440/5540 meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 23,711 Southern-approved options within PW5440/5540 spanning SHGC down to 0.07. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### Does PW5440/5540 carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 279 of 25,346 PW5440/5540 glazing builds earn Most Efficient recognition (1.1%), while other variants sit on the standard Version 7.0 tier.

### What 2026 federal tax credit and Lead RRP rules apply to PW5440/5540?

Any PW5440/5540 purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How do building inspectors verify PW5440/5540 glass specs on job sites?

Verify NFRC ID PGT and series PGT-A-233 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for PGT Industries PW5440/5540 come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)