---
title: "Polaris Windows and Doors 7420/3120/8620 Double Hung Specs"
url: https://ela-ecolandscapingassn.org/windows/models/polaris-windows-and-doors-7420-3120-8620-double-hung-413935/
description: "Polaris Windows and Doors 7420/3120/8620 Double Hung (POL-M-42, Double Hung, Vinyl): U-Factor 0.15-0.32, SHGC 0.15-0.51, 1340 options across 4 ENERGY STAR."
---

Window · Vinyl Frame NFRC POL · Product Line POL-M-42 ENERGY STAR Most Efficient Eligible

# Polaris Windows and Doors — 7420/3120/8620 Double Hung · Double Hung

EPA ENERGY STAR Version 7.0 certifies 1,340 variants inside Polaris Windows and Doors 7420/3120/8620 Double Hung, combining Vinyl frame construction with U-Factors spanning 0.15 to 0.32 and SHGC 0.15 to 0.51. Qualifying for Northern, North-Central, South-Central, Southern, this Double Hung family places #136 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.15

- **SHGC Range** : 0.15-0.51

- **Certified Options** : 1,340

- **Category Standing** : #136 of 1,352

## How does Polaris Windows and Doors 7420/3120/8620 Double Hung compare thermally against Window peers?

Polaris Windows and Doors 7420/3120/8620 Double Hung achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 7420/3120/8620 Double Hung spans 1,340 NFRC test records (POL), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at -0.04 against the Vinyl median (0.19).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 579 configurations meet ENERGY STAR Most Efficient criteria while 721 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2025-02-20. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.15 conducts 90.0 BTU/hr (-42.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,340 certified glazing combinations for 7420/3120/8620 Double Hung (NFRC POL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 721 packages (295 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 977 packages (489 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 816 packages (400 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 835 packages (490 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**EnergyWall Window** — 7420/3120/8620 Double Hung](https://ela-ecolandscapingassn.org/windows/models/energywall-window-7420-3120-8620-double-hung-413226/) | Vinyl | 0.15 | 0.15 | 1,340 |
| [**EnergyWall Window** — 7430/3130/8630 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/energywall-window-7430-3130-8630-horizontal-slider-413227/) | Vinyl | 0.15 | 0.14 | 1,348 |
| [**Euroline Windows Inc.** — Energeto Neo-76 Tilt and Turn Window](https://ela-ecolandscapingassn.org/windows/models/euroline-windows-inc-energeto-neo-76-tilt-and-turn-window-413024/) | Vinyl | 0.15 | 0.13 | 1,299 |
| [**Interstate Building Materials, Inc.** — 442/6802 Awning](https://ela-ecolandscapingassn.org/windows/models/interstate-building-materials-inc-442-6802-awning-413333/) | Vinyl | 0.15 | 0.15 | 1,544 |
| [**ProVia LLC** — Endure Single Slide](https://ela-ecolandscapingassn.org/windows/models/provia-llc-endure-single-slide-413958/) | Vinyl | 0.15 | 0.12 | 1,117 |

## What other certified series does Polaris Windows and Doors produce?

Compare other active Polaris Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [8605/3205 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/polaris-windows-and-doors-8605-3205-casement-picture-window-413939/)

U-Factor 0.13–0.29 · 3,472 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/polaris-windows-and-doors-8605-3205-casement-picture-window-413939/)

Picture WindowMin U 0.14

### [7400/3100 Picture Window](https://ela-ecolandscapingassn.org/windows/models/polaris-windows-and-doors-7400-3100-picture-window-413934/)

U-Factor 0.14–0.29 · 3,407 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/polaris-windows-and-doors-7400-3100-picture-window-413934/)

Double SliderMin U 0.15

### [7430/3130 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/polaris-windows-and-doors-7430-3130-horizontal-slider-413936/)

U-Factor 0.15–0.32 · 1,348 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/polaris-windows-and-doors-7430-3130-horizontal-slider-413936/)

Casement WindowsMin U 0.15

### [8650/3151 Casement](https://ela-ecolandscapingassn.org/windows/models/polaris-windows-and-doors-8650-3151-casement-413937/)

U-Factor 0.15–0.27 · 2,568 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/polaris-windows-and-doors-8650-3151-casement-413937/)

Awning (Projected)Min U 0.15

### [8660 Awning](https://ela-ecolandscapingassn.org/windows/models/polaris-windows-and-doors-8660-awning-413938/)

U-Factor 0.15–0.27 · 2,542 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/polaris-windows-and-doors-8660-awning-413938/)

Sliding Patio DoorMin U 0.16

### [8480/7480/3080 Patio Door](https://ela-ecolandscapingassn.org/windows/models/polaris-windows-and-doors-8480-7480-3080-patio-door-413933/)

U-Factor 0.16–0.28 · 3,179 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/polaris-windows-and-doors-8480-7480-3080-patio-door-413933/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Polaris Windows and Doors 7420/3120/8620 Double Hung appear below.

### How well does 7420/3120/8620 Double Hung by Polaris Windows and Doors insulate relative to Window benchmarks?

Across 1,340 tested NFRC glazing configurations, Polaris Windows and Doors 7420/3120/8620 Double Hung with Vinyl framing and Double-Hung (VSDH) style reaches a 0.15 minimum U-Factor and 0.15-0.51 SHGC band. It places #136 among 1,352 Window series—top 18.4%.

### Does Polaris Windows and Doors 7420/3120/8620 Double Hung qualify for the ENERGY STAR Northern Zone?

Yes. 721 packages in Polaris Windows and Doors 7420/3120/8620 Double Hung clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

### What BTU/hr heat transfer results from 7420/3120/8620 Double Hung's 0.15 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 7420/3120/8620 Double Hung at U 0.15 conducts 90.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### When should a buyer skip Polaris Windows and Doors 7420/3120/8620 Double Hung and compare alternatives?

Do not specify 7420/3120/8620 Double Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 7420/3120/8620 Double Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### How many 7420/3120/8620 Double Hung glazing packages pass Southern solar-heat rules?

Yes. 835 Southern-certified options inside Polaris Windows and Doors 7420/3120/8620 Double Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.51 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Does 7420/3120/8620 Double Hung carry EPA Most Efficient certification across its lineup?

Only 579 options out of 1,340 (43.2%) meet tighter Most Efficient U-Factor and SHGC thresholds in Polaris Windows and Doors 7420/3120/8620 Double Hung, usually requiring triple-pane or upgraded Low-E coatings.

### Can homeowners claim Form 5695 credits on Polaris Windows and Doors 7420/3120/8620 Double Hung in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Polaris Windows and Doors upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### Where are NFRC and IGCC identification marks located on 7420/3120/8620 Double Hung?

Verify NFRC ID POL and series POL-M-42 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Polaris Windows and Doors 7420/3120/8620 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
