title: "ProVia 502 / 602 Horizontal Slider Specs (U 0.16)"
url: https://ela-ecolandscapingassn.org/windows/models/provia-llc-502-602-horizontal-slider-413950/
description: "ProVia 502 / 602 Horizontal Slider (PRD-N-102, Double Slider, Vinyl): U-Factor 0.16-0.32, SHGC 0.05-0.46, 957 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC PRD · Product Line PRD-N-102 ENERGY STAR Most Efficient Eligible

# ProVia LLC — 502 / 602 Horizontal Slider · Double Slider

EPA ENERGY STAR Version 7.0 certifies 957 variants inside ProVia LLC 502 / 602 Horizontal Slider, combining Vinyl frame construction with U-Factors spanning 0.16 to 0.32 and SHGC 0.05 to 0.46. Qualifying for Northern, North-Central, South-Central, Southern, this Double Slider family places #250 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.16

- **SHGC Range** : 0.05-0.46

- **Certified Options** : 957

- **Category Standing** : #250 of 1,352

## How does ProVia LLC 502 / 602 Horizontal Slider compare thermally against Window peers?

ProVia LLC 502 / 602 Horizontal Slider achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places ProVia LLC 502 / 602 Horizontal Slider at rank #250 of 1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.05-0.46 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 229 configurations meet ENERGY STAR Most Efficient criteria while 201 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-10-11 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 96.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 957 certified glazing combinations for 502 / 602 Horizontal Slider (NFRC PRD) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 201 packages (66 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 463 packages (168 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 664 packages (156 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 861 packages (217 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Interstate Building Materials, Inc.** — 440/6800/8800 Double Hung](https://ela-ecolandscapingassn.org/windows/models/interstate-building-materials-inc-440-6800-8800-double-hung-413322/) | Vinyl | 0.16 | 0.18 | 920 |
| [**DRUTEX S.A.** — IGLO 5 Fixed Window with GU Threshold](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-fixed-window-with-gu-threshold-413165/) | Vinyl | 0.16 | 0.16 | 774 |
| [**Gerkin Windows and Doors** — 4300 Series Casement](https://ela-ecolandscapingassn.org/windows/models/gerkin-windows-and-doors-4300-series-casement-413263/) | Vinyl | 0.16 | 0.08 | 1,268 |
| [**Amsco Windows** — VLS STC Serenity Picture Window](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-picture-window-412894/) | Vinyl | 0.16 | 0.12 | 1,272 |
| [**Thermo-Tech Windows** — 2600 Casement w/ 2601 Sash](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-2600-casement-w-2601-sash-414176/) | Vinyl | 0.16 | 0.11 | 607 |

## What other certified series does ProVia LLC produce?

Compare other active ProVia LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Swinging Entry Door (Single)Min U 0.09

### [Premium Fiberglass Entry Door](https://ela-ecolandscapingassn.org/windows/models/provia-llc-premium-fiberglass-entry-door-413942/)

U-Factor 0.09–0.28 · 23,856 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-premium-fiberglass-entry-door-413942/)

Swinging Entry Door (Single)Min U 0.12

### [Fiberglass Entry Door](https://ela-ecolandscapingassn.org/windows/models/provia-llc-fiberglass-entry-door-413940/)

U-Factor 0.12–0.28 · 38,144 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-fiberglass-entry-door-413940/)

Picture WindowMin U 0.13

### [New Aspect/Endure Picture Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-new-aspect-endure-picture-window-413957/)

U-Factor 0.13–0.31 · 404 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-new-aspect-endure-picture-window-413957/)

Picture WindowMin U 0.13

### [Vinyl Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-vinyl-casement-picture-window-413953/)

U-Factor 0.13–0.31 · 365 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-vinyl-casement-picture-window-413953/)

Picture WindowMin U 0.14

### [Endure Picture Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-endure-picture-window-413959/)

U-Factor 0.14–0.32 · 1,106 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-endure-picture-window-413959/)

Picture WindowMin U 0.14

### [Vinyl Picture Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-vinyl-picture-window-413948/)

U-Factor 0.14–0.32 · 1,136 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-vinyl-picture-window-413948/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to ProVia LLC 502 / 602 Horizontal Slider appear below.

### What U-Factor and SHGC range does ProVia LLC 502 / 602 Horizontal Slider achieve?

ProVia LLC 502 / 602 Horizontal Slider spans 957 certified configurations with U-Factors between 0.16 and 0.32 and SHGC values from 0.05 to 0.46. Ranked #250 of 1,352 Window families, it carries 229 Most Efficient options.

### Can homeowners install 502 / 602 Horizontal Slider in cold Northern ENERGY STAR counties?

ProVia LLC 502 / 602 Horizontal Slider supplies 201 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

### How much winter heat loss does 502 / 602 Horizontal Slider conduct across a 15 sq ft opening?

Using NFRC PRD U-Factor 0.16, a 15 sq ft Dual-Slide Horizontal (HSXX) assembly conducts 96.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-36.0 BTU/hr margin).

### Which situations make 502 / 602 Horizontal Slider the wrong window or door choice?

Skip 502 / 602 Horizontal Slider if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 502 / 602 Horizontal Slider options exceeding U 0.22.

### How many 502 / 602 Horizontal Slider glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 861 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside ProVia LLC 502 / 602 Horizontal Slider, while total line SHGC reaches 0.46 in colder packages.

### What glazing share inside 502 / 602 Horizontal Slider qualifies as Most Efficient?

Not every package qualifies: 229 of 957 502 / 602 Horizontal Slider glazing builds earn Most Efficient recognition (23.9%), while other variants sit on the standard Version 7.0 tier.

### How do the 25C sunset and pre-1978 Lead RRP rules affect 502 / 602 Horizontal Slider?

Any 502 / 602 Horizontal Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How do you cross-check NFRC PRD and product line PRD-N-102 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code PRD and product line PRD-N-102, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for ProVia LLC 502 / 602 Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)