title: "ProVia New Aspect/Endure Picture Window Specs (U 0.13)"
url: https://ela-ecolandscapingassn.org/windows/models/provia-llc-new-aspect-endure-picture-window-413957/
description: "ProVia New Aspect/Endure Picture Window (PRD-N-112, Picture Window, Vinyl): U-Factor 0.13-0.31, SHGC 0.14-0.58, 404 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC PRD · Product Line PRD-N-112 ENERGY STAR Most Efficient Eligible

# ProVia LLC — New Aspect/Endure Picture Window · Picture Window

ProVia LLC New Aspect/Endure Picture Window is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.13 across 404 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #36 of 1,352 in Window, its thermal floor is 0.07 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.58.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.13

- **SHGC Range** : 0.14-0.58

- **Certified Options** : 404

- **Category Standing** : #36 of 1,352

## How does ProVia LLC New Aspect/Endure Picture Window compare thermally against Window peers?

ProVia LLC New Aspect/Endure Picture Window achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places ProVia LLC New Aspect/Endure Picture Window at rank #36 of 1,352 (tied with 35 others at 0.13, more insulating than 94.7% of Window lines, top 5.3%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.14-0.58 band.

Regional qualification covers Northern, North-Central, South-Central, Southern. 177 configurations meet ENERGY STAR Most Efficient criteria while 281 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-10-11 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 78.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 404 certified glazing combinations for New Aspect/Endure Picture Window (NFRC PRD) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 281 packages (104 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 296 packages (138 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 193 packages (80 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 204 packages (119 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Advanced Window Corp.** — EU 76 Septem Fixed](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-fixed-412865/) | Vinyl | 0.13 | 0.15 | 300 |
| [**North Star Manufacturing (London) Ltd.** — 1071 Fixed](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1071-fixed-413828/) | Vinyl | 0.13 | 0.17 | 205 |
| [**Slocomb Windows and Doors, Inc** — 100 Series Picture Window](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-100-series-picture-window-414102/) | Vinyl | 0.13 | 0.15 | 158 |
| [**Harvey Industries, Inc.** — Axio Direct Set Fixed Window](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-axio-direct-set-fixed-window-413307/) | Vinyl | 0.13 | 0.17 | 725 |
| [**Vytex Corporation** — 3300 Fixed](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-fixed-414300/) | Vinyl | 0.13 | 0.15 | 78 |

## What other certified series does ProVia LLC produce?

Compare other active ProVia LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Swinging Entry Door (Single)Min U 0.09

### [Premium Fiberglass Entry Door](https://ela-ecolandscapingassn.org/windows/models/provia-llc-premium-fiberglass-entry-door-413942/)

U-Factor 0.09–0.28 · 23,856 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-premium-fiberglass-entry-door-413942/)

Swinging Entry Door (Single)Min U 0.12

### [Fiberglass Entry Door](https://ela-ecolandscapingassn.org/windows/models/provia-llc-fiberglass-entry-door-413940/)

U-Factor 0.12–0.28 · 38,144 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-fiberglass-entry-door-413940/)

Picture WindowMin U 0.13

### [Vinyl Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-vinyl-casement-picture-window-413953/)

U-Factor 0.13–0.31 · 365 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-vinyl-casement-picture-window-413953/)

Picture WindowMin U 0.14

### [Endure Picture Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-endure-picture-window-413959/)

U-Factor 0.14–0.32 · 1,106 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-endure-picture-window-413959/)

Picture WindowMin U 0.14

### [Vinyl Picture Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-vinyl-picture-window-413948/)

U-Factor 0.14–0.32 · 1,136 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-vinyl-picture-window-413948/)

Picture WindowMin U 0.14

### [Wood Clad Vinyl Picture Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-wood-clad-vinyl-picture-window-413944/)

U-Factor 0.14–0.30 · 175 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-wood-clad-vinyl-picture-window-413944/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to ProVia LLC New Aspect/Endure Picture Window appear below.

### What U-Factor and SHGC range does ProVia LLC New Aspect/Endure Picture Window achieve?

Testing puts ProVia LLC New Aspect/Endure Picture Window at rank #36 of 1,352 Window entries with U 0.13 to 0.31 across 404 configurations. Solar heat gain ranges between 0.14 and 0.58 across Northern, North-Central, South-Central, Southern.

### Is New Aspect/Endure Picture Window approved for Northern Zone heating climates?

Cold-climate buyers get 281 compliant Northern packages inside New Aspect/Endure Picture Window, reaching down to U 0.13. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.31 options.

### How do you calculate winter heat conduction for ProVia LLC New Aspect/Endure Picture Window?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 78.0 BTU/hr on New Aspect/Endure Picture Window's lowest-U package (0.13), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.31 transfer proportionally more energy.

### Who should NOT choose ProVia LLC New Aspect/Endure Picture Window for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on New Aspect/Endure Picture Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### How many New Aspect/Endure Picture Window glazing packages pass Southern solar-heat rules?

Yes, New Aspect/Endure Picture Window holds 204 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.14 SHGC in cooling climates.

### How many ProVia LLC New Aspect/Endure Picture Window variants earn ENERGY STAR Most Efficient?

EPA lists 177 Most Efficient options (43.8% share) inside ProVia LLC New Aspect/Endure Picture Window, out of 404 total Version 7.0 entries.

### Can homeowners claim Form 5695 credits on ProVia LLC New Aspect/Endure Picture Window in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How do building inspectors verify New Aspect/Endure Picture Window glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code PRD and product line PRD-N-112, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for ProVia LLC New Aspect/Endure Picture Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)