title: "ProVia Wood Clad Vinyl Casement Specs (U 0.17)"
url: https://ela-ecolandscapingassn.org/windows/models/provia-llc-wood-clad-vinyl-casement-413946/
description: "ProVia Wood Clad Vinyl Casement (PRD-N-93, Casement Windows, Wood): U-Factor 0.17-0.32, SHGC 0.06-0.40, 232 options across 4 ENERGY STAR zones."
---

Window · Wood Frame NFRC PRD · Product Line PRD-N-93 ENERGY STAR Most Efficient Eligible

# ProVia LLC — Wood Clad Vinyl Casement · Casement Windows

ProVia LLC Wood Clad Vinyl Casement is a Casement Windows assembly with a Wood frame that reaches a minimum U-Factor of 0.17 across 232 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #362 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.06 to 0.40.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.06-0.40

- **Certified Options** : 232

- **Category Standing** : #362 of 1,352

## How does ProVia LLC Wood Clad Vinyl Casement compare thermally against Window peers?

ProVia LLC Wood Clad Vinyl Casement achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Wood Clad Vinyl Casement is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.32.

Mapping NFRC SHGC values (0.06 to 0.40) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 60 configurations meet ENERGY STAR Most Efficient criteria while 34 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2023-11-15 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 102.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 232 certified glazing combinations for Wood Clad Vinyl Casement (NFRC PRD) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 34 packages (3 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 131 packages (45 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 185 packages (45 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 224 packages (60 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Lepage Millwork** — XL-300 & XL-200 Hung](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-xl-300-xl-200-hung-413515/) | Wood | 0.17 | 0.14 | 108 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra Sterling Double Hung](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-sterling-double-hung-413464/) | Wood | 0.17 | 0.09 | 638 |
| [**Windsor Windows and Doors** — Pinnacle Clad Direct Set 3.25" Frame](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-direct-set-3-25-frame-414452/) | Wood | 0.17 | 0.13 | 817 |
| [**Weather Shield Mfg., Inc.** — 8211/8216/1209/1210 Premium Casement Picture](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-premium-casement-picture/) | Wood | 0.17 | 0.12 | 885 |
| [**Pella Corporation** — Pella Architect Wood Awning](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-architect-wood-awning-413885/) | Wood | 0.17 | 0.11 | 917 |

## What other certified series does ProVia LLC produce?

Compare other active ProVia LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Swinging Entry Door (Single)Min U 0.09

### [Premium Fiberglass Entry Door](https://ela-ecolandscapingassn.org/windows/models/provia-llc-premium-fiberglass-entry-door-413942/)

U-Factor 0.09–0.28 · 23,856 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-premium-fiberglass-entry-door-413942/)

Swinging Entry Door (Single)Min U 0.12

### [Fiberglass Entry Door](https://ela-ecolandscapingassn.org/windows/models/provia-llc-fiberglass-entry-door-413940/)

U-Factor 0.12–0.28 · 38,144 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-fiberglass-entry-door-413940/)

Picture WindowMin U 0.13

### [New Aspect/Endure Picture Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-new-aspect-endure-picture-window-413957/)

U-Factor 0.13–0.31 · 404 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-new-aspect-endure-picture-window-413957/)

Picture WindowMin U 0.13

### [Vinyl Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-vinyl-casement-picture-window-413953/)

U-Factor 0.13–0.31 · 365 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-vinyl-casement-picture-window-413953/)

Picture WindowMin U 0.14

### [Endure Picture Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-endure-picture-window-413959/)

U-Factor 0.14–0.32 · 1,106 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-endure-picture-window-413959/)

Picture WindowMin U 0.14

### [Vinyl Picture Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-vinyl-picture-window-413948/)

U-Factor 0.14–0.32 · 1,136 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/provia-llc-vinyl-picture-window-413948/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to ProVia LLC Wood Clad Vinyl Casement appear below.

### What thermal performance numbers separate ProVia LLC Wood Clad Vinyl Casement from peers?

EPA ENERGY STAR v7.0 records 232 configurations for ProVia LLC Wood Clad Vinyl Casement covering Northern, North-Central, South-Central, Southern, dropping down to U 0.17 versus a 0.20 Window median. Only 60 options earn Most Efficient status.

### How does ProVia LLC Wood Clad Vinyl Casement satisfy Version 7.0 Northern criteria?

Prescriptive Northern compliance covers 34 Wood Clad Vinyl Casement packages (U floor 0.17, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

### What BTU/hr heat transfer results from Wood Clad Vinyl Casement's 0.17 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Wood Clad Vinyl Casement at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### When should a buyer skip ProVia LLC Wood Clad Vinyl Casement and compare alternatives?

Do not specify Wood Clad Vinyl Casement without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Wood Clad Vinyl Casement options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### What Southern ENERGY STAR v7.0 options exist in Wood Clad Vinyl Casement?

Yes, Wood Clad Vinyl Casement holds 224 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.06 SHGC in cooling climates.

### Which package tier in Wood Clad Vinyl Casement holds Most Efficient recognition?

No. Exactly 60 of 232 configurations (25.9%) earn ENERGY STAR Most Efficient status in Wood Clad Vinyl Casement; the remaining standard v7.0 options pass base zone limits only.

### What 2026 federal tax credit and Lead RRP rules apply to Wood Clad Vinyl Casement?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How can homeowners confirm delivered ProVia LLC Wood Clad Vinyl Casement units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code PRD and product line PRD-N-93, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for ProVia LLC Wood Clad Vinyl Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)