Window · Aluminum Frame NFRC QWP · Product Line QWP-M-146 ENERGY STAR Most Efficient Eligible

# Quaker Window Products — H4503 Casement · Casement Windows

Across 25 Quaker Window Products certified families, H4503 Casement supplies 4,513 Casement Windows configurations starting at 0.21 U-Factor and 0.12 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.42 SHGC. Its thermal floor ranks #742 of 1,352 category entries—0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.21

- **SHGC Range** : 0.12-0.42

- **Certified Options** : 4,513

- **Category Standing** : #742 of 1,352

## How does Quaker Window Products H4503 Casement compare thermally against Window peers?

Quaker Window Products H4503 Casement achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Quaker Window Products H4503 Casement at rank #742 of 1,352 (tied with 88 others at 0.21, more insulating than 38.6% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.12-0.42 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 100 configurations meet ENERGY STAR Most Efficient criteria while 82 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors QWP to 2026-07-21 certification (FENSTAR issued 2018-02-20). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 126.0 BTU/hr conductive loss (-4.5% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 4,513 certified glazing combinations for H4503 Casement (NFRC QWP) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 82 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 827 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 1,839 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 4,331 packages (100 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**JELD-WEN, inc.** — Builders Vinyl (V-2500) Fixed w/ Track Filler](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-builders-vinyl-v-2500-fixed-w-track-filler-413364/) | Vinyl | 0.21 | 0.14 | 4,542 |
| [**Andersen Corporation** — 100 Series/Series 2 Fixed/Specialty Overfit Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-100-series-series-2-fixed-specialty-overfit-win/) | Composite / Vinyl | 0.21 | 0.17 | 4,022 |
| [**Milgard Manufacturing, Inc.** — 8225 Double Hung](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8225-double-hung-413739/) | Vinyl | 0.21 | 0.10 | 5,062 |
| [**MI Windows and Doors, LLC** — 4300 Polyvinyl Chloride (PVC) Single Hung Window](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-4300-polyvinyl-chloride-pvc-single-hung-win/) | Vinyl | 0.21 | 0.09 | 3,723 |
| [**Wincore Window Company, LLC** — 400 500 Vinyl Fixed Window Transom](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-400-500-vinyl-fixed-window-transom-414344/) | Vinyl | 0.21 | 0.13 | 2,892 |

## What other certified series does Quaker Window Products produce?

Compare other active Quaker Window Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [V300 Direct Set Narrow](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-direct-set-narrow-413983/)

U-Factor 0.14–0.32 · 9,693 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-direct-set-narrow-413983/)

Picture WindowMin U 0.15

### [C600/C300 Fixed](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-c600-c300-fixed-413989/)

U-Factor 0.15–0.32 · 4,805 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-c600-c300-fixed-413989/)

Picture WindowMin U 0.15

### [H4503 Fixed Picture Window](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-h4503-fixed-picture-window-414001/)

U-Factor 0.15–0.32 · 3,262 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-h4503-fixed-picture-window-414001/)

Swinging Entry Door (Single)Min U 0.16

### [V300 Inswing Door](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-inswing-door-413999/)

U-Factor 0.16–0.28 · 17,041 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-inswing-door-413999/)

Swinging Entry Door (Single)Min U 0.16

### [V300/V600 Outswing Door](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-v600-outswing-door-413998/)

U-Factor 0.16–0.28 · 16,974 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-v600-outswing-door-413998/)

Awning (Projected)Min U 0.17

### [V300 Awning](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-awning-413982/)

U-Factor 0.17–0.31 · 11,097 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-awning-413982/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Quaker Window Products H4503 Casement appear below.

### How well does H4503 Casement by Quaker Window Products insulate relative to Window benchmarks?

Built with Aluminum framing in Casement Single-Vent (CSSV) style, Quaker Window Products H4503 Casement offers 4,513 Version 7.0 configurations from U 0.21 up to 0.32, posting +0.01 against the Window median of 0.20 with 100 Most Efficient picks.

### Is H4503 Casement approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 82 H4503 Casement packages (U floor 0.21, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

### How do you calculate winter heat conduction for Quaker Window Products H4503 Casement?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 126.0 BTU/hr on H4503 Casement's lowest-U package (0.21), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### Who should NOT choose Quaker Window Products H4503 Casement for a residential project?

Do not specify H4503 Casement without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on H4503 Casement options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Can you install Quaker Window Products H4503 Casement in Southern or South-Central zones?

Yes. 4,331 Southern-certified options inside Quaker Window Products H4503 Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.42 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Does H4503 Casement carry EPA Most Efficient certification across its lineup?

No. Exactly 100 of 4,513 configurations (2.2%) earn ENERGY STAR Most Efficient status in H4503 Casement; the remaining standard v7.0 options pass base zone limits only.

### What federal compliance checks govern 2026 H4503 Casement window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How do building inspectors verify H4503 Casement glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line QWP-M-146 and NFRC ID QWP before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Quaker Window Products H4503 Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)