title: "Quaker Window Products H4503 Fixed Picture Window Specs"
url: https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-h4503-fixed-picture-window-414001/
description: "Quaker Window Products H4503 Fixed Picture Window (QWP-M-145, Picture Window, Aluminum): U-Factor 0.15-0.32, SHGC 0.14-0.53, 3262 options across 4 ENERGY."
---

Window · Aluminum Frame NFRC QWP · Product Line QWP-M-145 ENERGY STAR Most Efficient Eligible

# Quaker Window Products — H4503 Fixed Picture Window · Picture Window

Quaker Window Products H4503 Fixed Picture Window is a Picture Window assembly with a Aluminum frame that reaches a minimum U-Factor of 0.15 across 3,262 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #136 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.53.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.15

- **SHGC Range** : 0.14-0.53

- **Certified Options** : 3,262

- **Category Standing** : #136 of 1,352

## How does Quaker Window Products H4503 Fixed Picture Window compare thermally against Window peers?

Quaker Window Products H4503 Fixed Picture Window achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), H4503 Fixed Picture Window is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Aluminum frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.15-0.32.

Mapping NFRC SHGC values (0.14 to 0.53) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 997 configurations meet ENERGY STAR Most Efficient criteria while 996 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2026-09-08 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 90.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,262 certified glazing combinations for H4503 Fixed Picture Window (NFRC QWP) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 996 packages (414 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 1,892 packages (670 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 2,015 packages (477 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 2,531 packages (743 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**DRUTEX S.A.** — MB-79N/MB-86N SI Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-mb-79n-mb-86n-si-fixed-window-413174/) | Aluminum | 0.15 | 0.04 | 2,540 |
| [**Foshan Xiaoluban Doors and Windows Co., Ltd.** — XLB-80 Fixed Window](https://ela-ecolandscapingassn.org/windows/models/foshan-xiaoluban-doors-and-windows-co-ltd-xlb-80-fixed-window-413252/) | Aluminum | 0.15 | 0.17 | 7 |
| [**JELD-WEN, inc.** — 8500 Hybrid Casement](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-casement-413394/) | Aluminum | 0.15 | 0.13 | 60,304 |
| [**Marvin** — Vivid Direct Glaze](https://ela-ecolandscapingassn.org/windows/models/marvin-vivid-direct-glaze-413657/) | Fiberglass | 0.15 | 0.06 | 3,255 |
| [**DRUTEX S.A.** — IGLO ENERGY Classic Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-classic-fixed-window-413149/) | Vinyl | 0.15 | 0.04 | 3,527 |

## What other certified series does Quaker Window Products produce?

Compare other active Quaker Window Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [V300 Direct Set Narrow](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-direct-set-narrow-413983/)

U-Factor 0.14–0.32 · 9,693 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-direct-set-narrow-413983/)

Picture WindowMin U 0.15

### [C600/C300 Fixed](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-c600-c300-fixed-413989/)

U-Factor 0.15–0.32 · 4,805 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-c600-c300-fixed-413989/)

Swinging Entry Door (Single)Min U 0.16

### [V300 Inswing Door](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-inswing-door-413999/)

U-Factor 0.16–0.28 · 17,041 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-inswing-door-413999/)

Swinging Entry Door (Single)Min U 0.16

### [V300/V600 Outswing Door](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-v600-outswing-door-413998/)

U-Factor 0.16–0.28 · 16,974 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-v600-outswing-door-413998/)

Awning (Projected)Min U 0.17

### [V300 Awning](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-awning-413982/)

U-Factor 0.17–0.31 · 11,097 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-awning-413982/)

Casement WindowsMin U 0.17

### [V300 Casement](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-casement-413981/)

U-Factor 0.17–0.32 · 11,114 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-casement-413981/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Quaker Window Products H4503 Fixed Picture Window appear below.

### Where does Quaker Window Products H4503 Fixed Picture Window stand thermally among ENERGY STAR Window lines?

Across 3,262 tested NFRC glazing configurations, Quaker Window Products H4503 Fixed Picture Window with Aluminum framing and Fixed Window (FIXD) style reaches a 0.15 minimum U-Factor and 0.14-0.53 SHGC band. It places #136 among 1,352 Window series—top 18.4%.

### Which glazing options in Quaker Window Products H4503 Fixed Picture Window meet Northern climate limits?

Yes, 996 packages satisfy Northern ENERGY STAR Version 7.0 rules in H4503 Fixed Picture Window. Pairing multi-pane insulation down to 0.15 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How does a 3x5 ft H4503 Fixed Picture Window window perform under a 40 deg F temperature drop?

At U 0.15, a standard 3x5 ft (15 sq ft) H4503 Fixed Picture Window opening transfers 90.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -42.0 BTU/hr difference.

### Which situations make H4503 Fixed Picture Window the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on H4503 Fixed Picture Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Can you install Quaker Window Products H4503 Fixed Picture Window in Southern or South-Central zones?

Warm-climate homeowners have 2,531 Southern-approved options within H4503 Fixed Picture Window spanning SHGC down to 0.14. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### Are all 3,262 H4503 Fixed Picture Window configurations ENERGY STAR Most Efficient?

EPA lists 997 Most Efficient options (30.6% share) inside Quaker Window Products H4503 Fixed Picture Window, out of 3,262 total Version 7.0 entries.

### How do the 25C sunset and pre-1978 Lead RRP rules affect H4503 Fixed Picture Window?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How do building inspectors verify H4503 Fixed Picture Window glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code QWP and product line QWP-M-145, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Quaker Window Products H4503 Fixed Picture Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)