Window · Wood Frame NFRC QWP · Product Line QWP-M-150 ENERGY STAR Most Efficient Eligible

# Quaker Window Products — I200W Aluminum Clad Wood Awning · Awning (Projected)

With a minimum U-Factor of 0.21—+0.01 compared against the 0.20 Window median—Quaker Window Products I200W Aluminum Clad Wood Awning spans 2,233 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code QWP, the Wood assembly includes 27 ENERGY STAR Most Efficient packages (1.2% of line) and offers SHGC packages between 0.12 and 0.41.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.21

- **SHGC Range** : 0.12-0.41

- **Certified Options** : 2,233

- **Category Standing** : #742 of 1,352

## How does Quaker Window Products I200W Aluminum Clad Wood Awning compare thermally against Window peers?

Quaker Window Products I200W Aluminum Clad Wood Awning achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 25 certified Quaker Window Products series, this Awning, Projected offers a 0.11 U-Factor adjustment span between 0.32 entry options and 0.21 top-performing glazing. Category standing is #742/1,352 (tied with 88 others at 0.21, more insulating than 38.6% of Window lines).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 27 configurations meet ENERGY STAR Most Efficient criteria while 35 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2026-04-29 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 126.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,233 certified glazing combinations for I200W Aluminum Clad Wood Awning (NFRC QWP) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 35 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 384 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 935 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 2,129 packages (27 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Andersen Corporation** — 400 Series Specialty Windows - Flexiframe®](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-specialty-windows-flexiframe-412917/) | Wood | 0.21 | 0.15 | 1,978 |
| [**Windsor Windows and Doors** — Pinnacle Primed Casement Picture](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-primed-casement-picture-414398/) | Wood | 0.21 | 0.15 | 1,334 |
| [**Windsor Windows and Doors** — Pinnacle Select Awning](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-select-awning-414437/) | Wood | 0.21 | 0.10 | 932 |
| [**Windsor Windows and Doors** — Pinnacle Select Casement](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-select-casement-414433/) | Wood | 0.21 | 0.10 | 928 |
| [**Windsor Windows and Doors** — Pinnacle Primed Direct Set](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-primed-direct-set-414400/) | Wood | 0.21 | 0.12 | 765 |

## What other certified series does Quaker Window Products produce?

Compare other active Quaker Window Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [V300 Direct Set Narrow](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-direct-set-narrow-413983/)

U-Factor 0.14–0.32 · 9,693 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-direct-set-narrow-413983/)

Picture WindowMin U 0.15

### [C600/C300 Fixed](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-c600-c300-fixed-413989/)

U-Factor 0.15–0.32 · 4,805 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-c600-c300-fixed-413989/)

Picture WindowMin U 0.15

### [H4503 Fixed Picture Window](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-h4503-fixed-picture-window-414001/)

U-Factor 0.15–0.32 · 3,262 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-h4503-fixed-picture-window-414001/)

Swinging Entry Door (Single)Min U 0.16

### [V300 Inswing Door](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-inswing-door-413999/)

U-Factor 0.16–0.28 · 17,041 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-inswing-door-413999/)

Swinging Entry Door (Single)Min U 0.16

### [V300/V600 Outswing Door](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-v600-outswing-door-413998/)

U-Factor 0.16–0.28 · 16,974 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-v600-outswing-door-413998/)

Awning (Projected)Min U 0.17

### [V300 Awning](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-awning-413982/)

U-Factor 0.17–0.31 · 11,097 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-awning-413982/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Quaker Window Products I200W Aluminum Clad Wood Awning appear below.

### How efficient is Quaker Window Products I200W Aluminum Clad Wood Awning compared with peer Window models?

Quaker Window Products I200W Aluminum Clad Wood Awning spans 2,233 certified configurations with U-Factors between 0.21 and 0.32 and SHGC values from 0.12 to 0.41. Ranked #742 of 1,352 Window families, it carries 27 Most Efficient options.

### Is I200W Aluminum Clad Wood Awning approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 35 I200W Aluminum Clad Wood Awning packages (U floor 0.21, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

### What conductive BTU/hr difference separates I200W Aluminum Clad Wood Awning from the 0.22 Northern rule?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 126.0 BTU/hr on I200W Aluminum Clad Wood Awning's lowest-U package (0.21), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### Which situations make I200W Aluminum Clad Wood Awning the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on I200W Aluminum Clad Wood Awning options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

### Is I200W Aluminum Clad Wood Awning suitable for sunbelt cooling-dominated homes?

Yes. 2,129 Southern-certified options inside Quaker Window Products I200W Aluminum Clad Wood Awning satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.41 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Does I200W Aluminum Clad Wood Awning carry EPA Most Efficient certification across its lineup?

No. Exactly 27 of 2,233 configurations (1.2%) earn ENERGY STAR Most Efficient status in I200W Aluminum Clad Wood Awning; the remaining standard v7.0 options pass base zone limits only.

### How do the 25C sunset and pre-1978 Lead RRP rules affect I200W Aluminum Clad Wood Awning?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Quaker Window Products upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How do you cross-check NFRC QWP and product line QWP-M-150 on delivery?

Match the NFRC thermal sticker for code QWP and line QWP-M-150 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Quaker Window Products I200W Aluminum Clad Wood Awning come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)