title: "Quaker Window Products V300 Awning Specs (U 0.17)"
url: https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-awning-413982/
description: "Quaker Window Products V300 Awning (QWP-M-94, Awning (Projected), Vinyl): U-Factor 0.17-0.31, SHGC 0.09-0.41, 11097 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC QWP · Product Line QWP-M-94 ENERGY STAR Most Efficient Eligible

# Quaker Window Products — V300 Awning · Awning (Projected)

Positioning #362/1,352 in certified Window, Quaker Window Products V300 Awning pairs Vinyl frame construction with 11,097 glazing options rated between 0.09 and 0.41 SHGC across Northern, North-Central, South-Central, Southern. Across 25 certified Quaker Window Products product families, its thermal resistance spans 0.17 to 0.31 U-Factor and the line includes 381 ENERGY STAR Most Efficient packages (3.4% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.09-0.41

- **Certified Options** : 11,097

- **Category Standing** : #362 of 1,352

## How does Quaker Window Products V300 Awning compare thermally against Window peers?

Quaker Window Products V300 Awning achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Quaker Window Products V300 Awning at rank #362 of 1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.09-0.41 band.

Climate coverage for Quaker Window Products V300 Awning spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 381 configurations meet ENERGY STAR Most Efficient criteria while 213 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2026-06-09 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 11,097 certified glazing combinations for V300 Awning (NFRC QWP) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 213 packages (78 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 1,922 packages (231 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 6,582 packages (183 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 10,597 packages (333 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**PGT Industries** — SH5400/5500](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-sh5400-5500-413924/) | Vinyl | 0.17 | 0.09 | 9,241 |
| [**Simonton Building Products, Inc. - Simonton Windows** — 325-325 AW](https://ela-ecolandscapingassn.org/windows/models/simonton-building-products-inc-simonton-windows-325-325-aw-414044/) | Vinyl | 0.17 | 0.09 | 13,343 |
| [**Simonton Building Products, Inc. - Simonton Windows** — 325-325 CA](https://ela-ecolandscapingassn.org/windows/models/simonton-building-products-inc-simonton-windows-325-325-ca-414043/) | Vinyl | 0.17 | 0.09 | 13,628 |
| [**PGT Industries** — HR5410/5510](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-hr5410-5510-413921/) | Vinyl | 0.17 | 0.08 | 8,277 |
| [**Vinylmax LLC** — DHA4 Double Hung](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-dha4-double-hung-414264/) | Vinyl | 0.17 | 0.14 | 7,745 |

## What other certified series does Quaker Window Products produce?

Compare other active Quaker Window Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [V300 Direct Set Narrow](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-direct-set-narrow-413983/)

U-Factor 0.14–0.32 · 9,693 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-direct-set-narrow-413983/)

Picture WindowMin U 0.15

### [C600/C300 Fixed](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-c600-c300-fixed-413989/)

U-Factor 0.15–0.32 · 4,805 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-c600-c300-fixed-413989/)

Picture WindowMin U 0.15

### [H4503 Fixed Picture Window](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-h4503-fixed-picture-window-414001/)

U-Factor 0.15–0.32 · 3,262 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-h4503-fixed-picture-window-414001/)

Swinging Entry Door (Single)Min U 0.16

### [V300 Inswing Door](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-inswing-door-413999/)

U-Factor 0.16–0.28 · 17,041 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-inswing-door-413999/)

Swinging Entry Door (Single)Min U 0.16

### [V300/V600 Outswing Door](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-v600-outswing-door-413998/)

U-Factor 0.16–0.28 · 16,974 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-v600-outswing-door-413998/)

Casement WindowsMin U 0.17

### [V300 Casement](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-casement-413981/)

U-Factor 0.17–0.32 · 11,114 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-casement-413981/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Quaker Window Products V300 Awning appear below.

### Where does Quaker Window Products V300 Awning stand thermally among ENERGY STAR Window lines?

Across 11,097 tested NFRC glazing configurations, Quaker Window Products V300 Awning with Vinyl framing and Projected Awning (PRAW) style reaches a 0.17 minimum U-Factor and 0.09-0.41 SHGC band. It places #362 among 1,352 Window series—top 35.2%.

### Which glazing options in Quaker Window Products V300 Awning meet Northern climate limits?

Yes. 213 packages in Quaker Window Products V300 Awning clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.31.

### What BTU/hr heat transfer results from V300 Awning's 0.17 minimum U-Factor?

At U 0.17, a standard 3x5 ft (15 sq ft) V300 Awning opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.

### Which situations make V300 Awning the wrong window or door choice?

Do not specify V300 Awning without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on V300 Awning options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### What Southern ENERGY STAR v7.0 options exist in V300 Awning?

Yes, V300 Awning holds 10,597 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.09 SHGC in cooling climates.

### How many Quaker Window Products V300 Awning variants earn ENERGY STAR Most Efficient?

No. Exactly 381 of 11,097 configurations (3.4%) earn ENERGY STAR Most Efficient status in V300 Awning; the remaining standard v7.0 options pass base zone limits only.

### How do the 25C sunset and pre-1978 Lead RRP rules affect V300 Awning?

Any V300 Awning purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### Where are NFRC and IGCC identification marks located on V300 Awning?

Confirm both the paper NFRC label and permanent corner glass etch match line QWP-M-94 and NFRC ID QWP before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Quaker Window Products V300 Awning come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)