# Ram Industries Inc. — S1100 Single Hung · Single Hung

Across 3 Ram Industries Inc. certified families, S1100 Single Hung supplies 68 Single Hung configurations starting at 0.31 U-Factor and 0.12 SHGC for Southern, reaching up to 0.32 U-Factor and 0.23 SHGC. Its thermal floor ranks #1,351 of 1,352 category entries—0.11 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.31

- **SHGC Range** : 0.12-0.23

- **Certified Options** : 68

- **Category Standing** : #1,351 of 1,352

## How does Ram Industries Inc. S1100 Single Hung compare thermally against Window peers?

Ram Industries Inc. S1100 Single Hung achieves a 0.31 thermal floor across Window lines, placing #1,351 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Aluminum cohort (0.23 median U-Factor), S1100 Single Hung reaches 0.31 on its lowest-conductivity package — #55 of 64 in Aluminum, tied with 2 others at 0.31, more insulating than 10.9% of Aluminum lines (+0.08 vs Aluminum peers). Pairing NFRC ID RAM across multi-pane fills shifts U-Factor from 0.32 down toward 0.31.

Climate coverage for Ram Industries Inc. S1100 Single Hung spans Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward Southern markets where low SHGC down to 0.12 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.31 U-Factor yields 186.0 BTU/hr transfer (+54.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2023-12-04 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 68 certified glazing combinations for S1100 Single Hung (NFRC RAM) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| **South-Central** | Not Listed | <= 0.28 | <= 0.23 | 0 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 68 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.31 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Value Windows & Doors** — AL-CM](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-al-cm-414277/) | Aluminum | 0.31 | 0.13 | 17 |
| [**MI Windows and Doors, LLC** — 1650I Polyvinyl Chloride (PVC) Double Hung Window](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-1650i-polyvinyl-chloride-pvc-double-hung-wi/) | Vinyl | 0.30 | 0.12 | 71 |
| [**Custom Window Systems, Inc.** — HS-8200 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-hs-8200-horizontal-slider-413142/) | Vinyl | 0.30 | 0.13 | 130 |
| [**Phos Window** — 1400 Single Hung](https://ela-ecolandscapingassn.org/windows/models/phos-window-1400-single-hung-413076/) | Vinyl | 0.30 | 0.20 | 4 |
| [**Phos Window** — 1400 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/phos-window-1400-horizontal-slider-413075/) | Vinyl | 0.29 | 0.20 | 4 |

## What other certified series does Ram Industries Inc. produce?

Compare other active Ram Industries Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.27

### [S800 Heavy Picture Window](https://ela-ecolandscapingassn.org/windows/models/ram-industries-inc-s800-heavy-picture-window-414006/)

U-Factor 0.27–0.32 · 252 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/ram-industries-inc-s800-heavy-picture-window-414006/)

Picture WindowMin U 0.29

### [S840 Heavy Picture Window](https://ela-ecolandscapingassn.org/windows/models/ram-industries-inc-s840-heavy-picture-window-414007/)

U-Factor 0.29–0.32 · 57 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/ram-industries-inc-s840-heavy-picture-window-414007/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Ram Industries Inc. S1100 Single Hung appear below.

### What U-Factor and SHGC range does Ram Industries Inc. S1100 Single Hung achieve?

Ram Industries Inc. S1100 Single Hung spans 68 certified configurations with U-Factors between 0.31 and 0.32 and SHGC values from 0.12 to 0.23. Ranked #1,351 of 1,352 Window families, it carries 0 Most Efficient options.

### How does Ram Industries Inc. S1100 Single Hung satisfy Version 7.0 Northern criteria?

No—with 0 Northern packages and a 0.31 thermal floor, Ram Industries Inc. S1100 Single Hung targets warmer Southern climates instead of cold Northern installations.

### What BTU/hr heat transfer results from S1100 Single Hung's 0.31 minimum U-Factor?

At U 0.31, a standard 3x5 ft (15 sq ft) S1100 Single Hung opening transfers 186.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +54.0 BTU/hr difference.

### Which situations make S1100 Single Hung the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on S1100 Single Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### What Southern ENERGY STAR v7.0 options exist in S1100 Single Hung?

Yes, S1100 Single Hung holds 68 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.12 SHGC in cooling climates.

### How many Ram Industries Inc. S1100 Single Hung variants earn ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 68 S1100 Single Hung options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

### How do the 25C sunset and pre-1978 Lead RRP rules affect S1100 Single Hung?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### Where are NFRC and IGCC identification marks located on S1100 Single Hung?

Match the NFRC thermal sticker for code RAM and line RAM-A-5 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Ram Industries Inc. S1100 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)