---
title: "Rogers Windows 9000/9002 Double Hung Specs (U 0.24)"
url: https://ela-ecolandscapingassn.org/windows/models/rogers-windows-inc-ky-9000-9002-double-hung-414014/
description: "Rogers Windows 9000/9002 Double Hung (ROG-K-2, Double Hung, Vinyl): U-Factor 0.24-0.29, SHGC 0.19-0.32, 56 options across 3 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC ROG · Product Line ROG-K-2

# Rogers Windows, Inc. - KY — 9000/9002 Double Hung · Double Hung

With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—Rogers Windows, Inc. - KY 9000/9002 Double Hung spans 56 tested options across North-Central, South-Central, Southern up to 0.29 U-Factor. Carrying NFRC CPD code ROG, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.19 and 0.32.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.24

- **SHGC Range** : 0.19-0.32

- **Certified Options** : 56

- **Category Standing** : #1,034 of 1,352

## How does Rogers Windows, Inc. - KY 9000/9002 Double Hung compare thermally against Window peers?

Rogers Windows, Inc. - KY 9000/9002 Double Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Rogers Windows, Inc. - KY 9000/9002 Double Hung standing at #1,034 of 1,352 certified Window product series, tied with 139 others at 0.24, more insulating than 13.2% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.05 before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 3 markets (North-Central, South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.19 lowers cooling load.

Lifecycle documentation anchors ROG to 2025-02-27 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 56 certified glazing combinations for 9000/9002 Double Hung (NFRC ROG) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 40 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 36 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 40 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Thermo-Twin Industries, Inc.** — S-700/731 Welded Double Hung](https://ela-ecolandscapingassn.org/windows/models/thermo-twin-industries-inc-s-700-731-welded-double-hung-414164/) | Vinyl | 0.24 | 0.18 | 58 |
| [**Paradigm Window Solutions** — 8381 Single Hung](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-8381-single-hung-413971/) | Vinyl | 0.24 | 0.26 | 52 |
| [**Thermo-Twin Industries, Inc.** — S-700/731 Welded Casement](https://ela-ecolandscapingassn.org/windows/models/thermo-twin-industries-inc-s-700-731-welded-casement-414165/) | Vinyl | 0.24 | 0.16 | 52 |
| [**Thermo-Twin Industries, Inc.** — S-700/731 Welded Awning](https://ela-ecolandscapingassn.org/windows/models/thermo-twin-industries-inc-s-700-731-welded-awning-414166/) | Vinyl | 0.24 | 0.16 | 51 |
| [**Northeast Building Products Corporation** — Camelot Pro-Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/northeast-building-products-corporation-camelot-pro-series-horizonta/) | Vinyl | 0.24 | 0.18 | 50 |

## What other certified series does Rogers Windows, Inc. - KY produce?

Compare other active Rogers Windows, Inc. - KY certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.23

### [9210/9210F Picture Window](https://ela-ecolandscapingassn.org/windows/models/rogers-windows-inc-ky-9210-9210f-picture-window-414016/)

U-Factor 0.23–0.27 · 48 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/rogers-windows-inc-ky-9210-9210f-picture-window-414016/)

Double SliderMin U 0.24

### [9000/9003 Vinyl Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/rogers-windows-inc-ky-9000-9003-vinyl-horizontal-slider-414015/)

U-Factor 0.24–0.28 · 88 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/rogers-windows-inc-ky-9000-9003-vinyl-horizontal-slider-414015/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Rogers Windows, Inc. - KY 9000/9002 Double Hung appear below.

### How well does 9000/9002 Double Hung by Rogers Windows, Inc. - KY insulate relative to Window benchmarks?

Across 56 tested NFRC glazing configurations, Rogers Windows, Inc. - KY 9000/9002 Double Hung with Vinyl framing and Double-Hung (VSDH) style reaches a 0.24 minimum U-Factor and 0.19-0.32 SHGC band. It places #1,034 among 1,352 Window series—more insulating than 13.2%.

### Can homeowners install 9000/9002 Double Hung in cold Northern ENERGY STAR counties?

Rogers Windows, Inc. - KY 9000/9002 Double Hung holds zero Northern Zone qualifications (min U 0.24). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

### How does a 3x5 ft 9000/9002 Double Hung window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 9000/9002 Double Hung at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### Who should NOT choose Rogers Windows, Inc. - KY 9000/9002 Double Hung for a residential project?

Skip 9000/9002 Double Hung if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 9000/9002 Double Hung options exceeding U 0.22.

### Does 9000/9002 Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 40 9000/9002 Double Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.19 rather than higher 0.32 glass.

### Does 9000/9002 Double Hung carry EPA Most Efficient certification across its lineup?

No. Zero of the 56 configurations in Rogers Windows, Inc. - KY 9000/9002 Double Hung hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

### What 2026 federal tax credit and Lead RRP rules apply to 9000/9002 Double Hung?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### Where are NFRC and IGCC identification marks located on 9000/9002 Double Hung?

Verify NFRC ID ROG and series ROG-K-2 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Rogers Windows, Inc. - KY 9000/9002 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
