title: "Seaway Manufacturing Amerivu Single Slider Specs (U 0.24)"
url: https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-amerivu-single-slider-414122/
description: "Seaway Manufacturing Amerivu Single Slider (SMA-A-28, Single Slider, Vinyl): U-Factor 0.24-0.32, SHGC 0.13-0.51, 1264 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC SMA · Product Line SMA-A-28

# Seaway Manufacturing Corporation — Amerivu Single Slider · Single Slider

With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—Seaway Manufacturing Corporation Amerivu Single Slider spans 1,264 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code SMA, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.13 and 0.51.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.24

- **SHGC Range** : 0.13-0.51

- **Certified Options** : 1,264

- **Category Standing** : #1,034 of 1,352

## How does Seaway Manufacturing Corporation Amerivu Single Slider compare thermally against Window peers?

Seaway Manufacturing Corporation Amerivu Single Slider achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 8 certified Seaway Manufacturing Corporation series, this Single Slider offers a 0.08 U-Factor adjustment span between 0.32 entry options and 0.24 top-performing glazing. Category standing is #1,034/1,352 (tied with 139 others at 0.24, more insulating than 13.2% of Window lines).

Climate coverage for Seaway Manufacturing Corporation Amerivu Single Slider spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 40 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 144.0 BTU/hr (+9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2023-11-21.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,264 certified glazing combinations for Amerivu Single Slider (NFRC SMA) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 40 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 178 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 228 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 1,146 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Windsor Windows and Doors** — Next Dimension Narrow Sliding Patio Door Transom](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-narrow-sliding-patio-door-t/) | Vinyl | 0.24 | 0.11 | 1,274 |
| [**YKK AP America, Inc.** — Precedence / Style View / Style Guard Awning Window](https://ela-ecolandscapingassn.org/windows/models/ykk-ap-america-inc-precedence-style-view-style-guard-awning-window-4/) | Vinyl | 0.24 | 0.17 | 1,237 |
| [**Amsco Windows** — V2K Basement Window](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-v2k-basement-window-412891/) | Vinyl | 0.24 | 0.13 | 1,114 |
| [**A Window, Inc.** — V-25/31 SH](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-v-25-31-sh-413081/) | Vinyl | 0.24 | 0.15 | 980 |
| [**A Window, Inc.** — V-25/31 SS](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-v-25-31-ss-413082/) | Vinyl | 0.24 | 0.15 | 970 |

## What other certified series does Seaway Manufacturing Corporation produce?

Compare other active Seaway Manufacturing Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Lighthouse/Commander Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-lighthouse-commander-casement-fixed/)

U-Factor 0.13–0.28 · 2,119 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-lighthouse-commander-casement-fixed/)

Awning (Projected)Min U 0.16

### [Lighthouse/Commander/Epiphany Awning](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-lighthouse-commander-epiphany-awnin/)

U-Factor 0.16–0.28 · 2,513 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-lighthouse-commander-epiphany-awnin/)

Casement WindowsMin U 0.16

### [Lighthouse/Commander/Epiphany Casement](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-lighthouse-commander-epiphany-casem/)

U-Factor 0.16–0.28 · 2,523 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-lighthouse-commander-epiphany-casem/)

Sliding Patio DoorMin U 0.20

### [Prima Vista S-7500 Patio Door](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-prima-vista-s-7500-patio-door-41411/)

U-Factor 0.20–0.28 · 456 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-prima-vista-s-7500-patio-door-41411/)

Sliding Patio DoorMin U 0.21

### [Grandview Patio Door](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-grandview-patio-door-414117/)

U-Factor 0.21–0.26 · 129 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-grandview-patio-door-414117/)

Picture WindowMin U 0.23

### [Amerivu Picture Window](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-amerivu-picture-window-414124/)

U-Factor 0.23–0.32 · 537 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-amerivu-picture-window-414124/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Seaway Manufacturing Corporation Amerivu Single Slider appear below.

### Where does Seaway Manufacturing Corporation Amerivu Single Slider stand thermally among ENERGY STAR Window lines?

Across 1,264 tested NFRC glazing configurations, Seaway Manufacturing Corporation Amerivu Single Slider with Vinyl framing and Horizontal Slider (HSOX) style reaches a 0.24 minimum U-Factor and 0.13-0.51 SHGC band. It places #1,034 among 1,352 Window series—more insulating than 13.2%.

### Is Amerivu Single Slider approved for Northern Zone heating climates?

While Seaway Manufacturing Corporation Amerivu Single Slider misses the <= 0.22 prescriptive mark (floor U 0.24), 40 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

### How does a 3x5 ft Amerivu Single Slider window perform under a 40 deg F temperature drop?

At U 0.24, a standard 3x5 ft (15 sq ft) Amerivu Single Slider opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.

### Who should NOT choose Seaway Manufacturing Corporation Amerivu Single Slider for a residential project?

Do not specify Amerivu Single Slider without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Amerivu Single Slider options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does Amerivu Single Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 1,146 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Seaway Manufacturing Corporation Amerivu Single Slider, while total line SHGC reaches 0.51 in colder packages.

### Are all 1,264 Amerivu Single Slider configurations ENERGY STAR Most Efficient?

All 1,264 Amerivu Single Slider listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

### Can homeowners claim Form 5695 credits on Seaway Manufacturing Corporation Amerivu Single Slider in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Amerivu Single Slider installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### Where are NFRC and IGCC identification marks located on Amerivu Single Slider?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code SMA and product line SMA-A-28, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Seaway Manufacturing Corporation Amerivu Single Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)