---
title: "Seaway Manufacturing Lighthouse/Commander/Epiphany Awning"
url: https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-lighthouse-commander-epiphany-awnin/
description: "Seaway Manufacturing Lighthouse/Commander/Epiphany Awning (SMA-A-22, Awning (Projected), Vinyl): U-Factor 0.16-0.28, SHGC 0.09-0.41, 2513 options across 4."
---

Window · Vinyl Frame NFRC SMA · Product Line SMA-A-22 ENERGY STAR Most Efficient Eligible

# Seaway Manufacturing Corporation — Lighthouse/Commander/Epiphany Awning · Awning (Projected)

Across 8 Seaway Manufacturing Corporation certified families, Lighthouse/Commander/Epiphany Awning supplies 2,513 Awning, Projected configurations starting at 0.16 U-Factor and 0.09 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.41 SHGC. Its thermal floor ranks #250 of 1,352 category entries—0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.16

- **SHGC Range** : 0.09-0.41

- **Certified Options** : 2,513

- **Category Standing** : #250 of 1,352

## How does Seaway Manufacturing Corporation Lighthouse/Commander/Epiphany Awning compare thermally against Window peers?

Seaway Manufacturing Corporation Lighthouse/Commander/Epiphany Awning achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Lighthouse/Commander/Epiphany Awning spans 2,513 NFRC test records (SMA), ranking #250 of 1,352 Window families (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%). Its 0.16 thermal floor compares at -0.03 against the Vinyl median (0.19).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 862 configurations meet ENERGY STAR Most Efficient criteria while 842 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors SMA to 2024-10-31 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 96.0 BTU/hr conductive loss (-27.3% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,513 certified glazing combinations for Lighthouse/Commander/Epiphany Awning (NFRC SMA) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 842 packages (518 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 1,273 packages (839 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 2,211 packages (753 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 2,211 packages (776 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Paradigm Window Solutions** — 8351 Casement](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-8351-casement-413973/) | Vinyl | 0.16 | 0.12 | 2,533 |
| [**Paradigm Window Solutions** — 8352 Awning](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-8352-awning-413974/) | Vinyl | 0.16 | 0.12 | 2,446 |
| [**Windsor Windows and Doors** — Next Dimension Picture](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-picture-414458/) | Vinyl | 0.16 | 0.12 | 1,539 |
| [**Interstate Building Materials, Inc.** — 440/6800/8800 Double Slider](https://ela-ecolandscapingassn.org/windows/models/interstate-building-materials-inc-440-6800-8800-double-slider-413323/) | Vinyl | 0.16 | 0.18 | 1,522 |
| [**DRUTEX S.A.** — IGLO Energy Fixed Window Plus COMBI Threshold](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-fixed-window-plus-combi-threshold-413163/) | Vinyl | 0.16 | 0.15 | 1,443 |

## What other certified series does Seaway Manufacturing Corporation produce?

Compare other active Seaway Manufacturing Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Lighthouse/Commander Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-lighthouse-commander-casement-fixed/)

U-Factor 0.13–0.28 · 2,119 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-lighthouse-commander-casement-fixed/)

Casement WindowsMin U 0.16

### [Lighthouse/Commander/Epiphany Casement](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-lighthouse-commander-epiphany-casem/)

U-Factor 0.16–0.28 · 2,523 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-lighthouse-commander-epiphany-casem/)

Sliding Patio DoorMin U 0.20

### [Prima Vista S-7500 Patio Door](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-prima-vista-s-7500-patio-door-41411/)

U-Factor 0.20–0.28 · 456 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-prima-vista-s-7500-patio-door-41411/)

Sliding Patio DoorMin U 0.21

### [Grandview Patio Door](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-grandview-patio-door-414117/)

U-Factor 0.21–0.26 · 129 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-grandview-patio-door-414117/)

Picture WindowMin U 0.23

### [Amerivu Picture Window](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-amerivu-picture-window-414124/)

U-Factor 0.23–0.32 · 537 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-amerivu-picture-window-414124/)

Single HungMin U 0.24

### [Amerivu Single Hung](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-amerivu-single-hung-414123/)

U-Factor 0.24–0.32 · 1,062 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-amerivu-single-hung-414123/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Seaway Manufacturing Corporation Lighthouse/Commander/Epiphany Awning appear below.

### What thermal performance numbers separate Seaway Manufacturing Corporation Lighthouse/Commander/Epiphany Awning from peers?

Testing puts Seaway Manufacturing Corporation Lighthouse/Commander/Epiphany Awning at rank #250 of 1,352 Window entries with U 0.16 to 0.28 across 2,513 configurations. Solar heat gain ranges between 0.09 and 0.41 across Northern, North-Central, South-Central, Southern.

### Does Seaway Manufacturing Corporation Lighthouse/Commander/Epiphany Awning qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 842 Lighthouse/Commander/Epiphany Awning packages (U floor 0.16, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

### How much winter heat loss does Lighthouse/Commander/Epiphany Awning conduct across a 15 sq ft opening?

Using NFRC SMA U-Factor 0.16, a 15 sq ft Projected Awning (PRAW) assembly conducts 96.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-36.0 BTU/hr margin).

### When should a buyer skip Seaway Manufacturing Corporation Lighthouse/Commander/Epiphany Awning and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Lighthouse/Commander/Epiphany Awning options exceeding U 0.22. Additionally, do not order Projected Awning (PRAW) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### Is Lighthouse/Commander/Epiphany Awning suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 2,211 Southern-approved options within Lighthouse/Commander/Epiphany Awning spanning SHGC down to 0.09. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### Are all 2,513 Lighthouse/Commander/Epiphany Awning configurations ENERGY STAR Most Efficient?

Not every package qualifies: 862 of 2,513 Lighthouse/Commander/Epiphany Awning glazing builds earn Most Efficient recognition (34.3%), while other variants sit on the standard Version 7.0 tier.

### What federal compliance checks govern 2026 Lighthouse/Commander/Epiphany Awning window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Seaway Manufacturing Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How do building inspectors verify Lighthouse/Commander/Epiphany Awning glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.16-0.28, SHGC 0.09-0.41) against permit drawings for line SMA-A-22. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Seaway Manufacturing Corporation Lighthouse/Commander/Epiphany Awning come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
