---
title: "Seven D Windows and Door 7700/7800 Awning Specs (U 0.17)"
url: https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-awning-414053/
description: "Seven D Windows and Door 7700/7800 Awning (SED-A-45, Awning (Projected), Vinyl): U-Factor 0.17-0.27, SHGC 0.19-0.31, 55 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC SED · Product Line SED-A-45 ENERGY STAR Most Efficient Eligible

# Seven D Windows and Door LLC — 7700/7800 Awning · Awning (Projected)

Seven D Windows and Door LLC 7700/7800 Awning is a Awning, Projected assembly with a Vinyl frame that reaches a minimum U-Factor of 0.17 across 55 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #362 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.19 to 0.31.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.19-0.31

- **Certified Options** : 55

- **Category Standing** : #362 of 1,352

## How does Seven D Windows and Door LLC 7700/7800 Awning compare thermally against Window peers?

Seven D Windows and Door LLC 7700/7800 Awning achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 7700/7800 Awning reaches 0.17 on its lowest-conductivity package — #271 of 1,009 in Vinyl, tied with 82 others at 0.17, more insulating than 65.0% of Vinyl lines, top 35.0% (-0.02 vs Vinyl peers). Pairing NFRC ID SED across multi-pane fills shifts U-Factor from 0.27 down toward 0.17.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 11 configurations meet ENERGY STAR Most Efficient criteria while 14 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-07-02. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.17 conducts 102.0 BTU/hr (-30.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 55 certified glazing combinations for 7700/7800 Awning (NFRC SED) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 14 packages (3 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 44 packages (6 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 40 packages (6 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 40 packages (11 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**OKNA Windows & Doors Mfg** — 400 Double Hung](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-400-double-hung-413860/) | Vinyl | 0.17 | 0.14 | 56 |
| [**OKNA Windows & Doors Mfg** — SL620-SL6620](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-sl620-sl6620-413872/) | Vinyl | 0.17 | 0.17 | 56 |
| [**National Vinyl, LLC** — TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/national-vinyl-llc-tg-nw3-destiny-duratrust-clarion-northwind-br-hor/) | Vinyl | 0.17 | 0.22 | 51 |
| [**Energex Window Alliance** — Energex Picture Window](https://ela-ecolandscapingassn.org/windows/models/energex-window-alliance-energex-picture-window-413197/) | Vinyl | 0.17 | 0.14 | 66 |
| [**Vector Windows** — Envision Glider](https://ela-ecolandscapingassn.org/windows/models/vector-windows-envision-glider-414029/) | Vinyl | 0.17 | 0.17 | 67 |

## What other certified series does Seven D Windows and Door LLC produce?

Compare other active Seven D Windows and Door LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [7700/7800 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-casement-picture-window-41405/)

U-Factor 0.14–0.25 · 60 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-casement-picture-window-41405/)

Picture WindowMin U 0.14

### [7700/7800 Picture Window](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-picture-window-414048/)

U-Factor 0.14–0.25 · 46 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-picture-window-414048/)

Sliding Patio DoorMin U 0.16

### [7700/7800 Patio Door](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-patio-door-414055/)

U-Factor 0.16–0.27 · 22 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-patio-door-414055/)

Single SliderMin U 0.16

### [7700/7800 Single Slider](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-single-slider-414051/)

U-Factor 0.16–0.25 · 24 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-single-slider-414051/)

Casement WindowsMin U 0.17

### [7700/7800 Casement](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-casement-414052/)

U-Factor 0.17–0.27 · 55 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-casement-414052/)

Single HungMin U 0.17

### [7700/7800 Single Hung](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-single-hung-414050/)

U-Factor 0.17–0.25 · 21 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-single-hung-414050/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Seven D Windows and Door LLC 7700/7800 Awning appear below.

### How well does 7700/7800 Awning by Seven D Windows and Door LLC insulate relative to Window benchmarks?

Testing puts Seven D Windows and Door LLC 7700/7800 Awning at rank #362 of 1,352 Window entries with U 0.17 to 0.27 across 55 configurations. Solar heat gain ranges between 0.19 and 0.31 across Northern, North-Central, South-Central, Southern.

### Does Seven D Windows and Door LLC 7700/7800 Awning qualify for the ENERGY STAR Northern Zone?

Yes, 14 packages satisfy Northern ENERGY STAR Version 7.0 rules in 7700/7800 Awning. Pairing multi-pane insulation down to 0.17 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How does a 3x5 ft 7700/7800 Awning window perform under a 40 deg F temperature drop?

Using NFRC SED U-Factor 0.17, a 15 sq ft Projected Awning (PRAW) assembly conducts 102.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-30.0 BTU/hr margin).

### Who should NOT choose Seven D Windows and Door LLC 7700/7800 Awning for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 7700/7800 Awning options exceeding U 0.22. Additionally, do not order Projected Awning (PRAW) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### Can you install Seven D Windows and Door LLC 7700/7800 Awning in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 40 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Seven D Windows and Door LLC 7700/7800 Awning, while total line SHGC reaches 0.31 in colder packages.

### Are all 55 7700/7800 Awning configurations ENERGY STAR Most Efficient?

Only 11 options out of 55 (20.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in Seven D Windows and Door LLC 7700/7800 Awning, usually requiring triple-pane or upgraded Low-E coatings.

### Do 2026 7700/7800 Awning installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Seven D Windows and Door LLC upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### What permanent glass etch marks verify 7700/7800 Awning after sticker removal?

Verify NFRC ID SED and series SED-A-45 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Seven D Windows and Door LLC 7700/7800 Awning come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
