title: "Seven D Windows and Door 7700/7800 XX Slider Specs"
url: https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-xx-slider-414054/
description: "Seven D Windows and Door 7700/7800 XX Slider (SED-A-46, Double Slider, Vinyl): U-Factor 0.18-0.29, SHGC 0.21-0.28, 56 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC SED · Product Line SED-A-46 ENERGY STAR Most Efficient Eligible

# Seven D Windows and Door LLC — 7700/7800 XX Slider · Double Slider

Seven D Windows and Door LLC engineered the 7700/7800 XX Slider Double Slider line for Northern, North-Central, South-Central, Southern, certifying 56 glass-spacer combinations from 0.18 to 0.29 U-Factor and 0.21 to 0.28 SHGC. Relative to other Vinyl models tracked under NFRC SED, its minimum U-Factor is 0.01 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.18

- **SHGC Range** : 0.21-0.28

- **Certified Options** : 56

- **Category Standing** : #477 of 1,352

## How does Seven D Windows and Door LLC 7700/7800 XX Slider compare thermally against Window peers?

Seven D Windows and Door LLC 7700/7800 XX Slider achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 7700/7800 XX Slider is 0.02 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.18-0.29.

Mapping NFRC SHGC values (0.21 to 0.28) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 18 configurations meet ENERGY STAR Most Efficient criteria while 21 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 108.0 BTU/hr (-18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-07-02.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 56 certified glazing combinations for 7700/7800 XX Slider (NFRC SED) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 21 packages (17 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 47 packages (17 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 24 packages (9 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 26 packages (10 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Vinyl Kraft, Inc.** — Legacy/Heritage/NR900/900NC/Obsidian DH](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-legacy-heritage-nr900-900nc-obsidian-dh-414229/) | Vinyl | 0.18 | 0.17 | 48 |
| [**Ideal Window Manufacturing** — Professional, Perfect Fit, Majestic, Lifescape, Rite and Platinum Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/ideal-window-manufacturing-professional-perfect-fit-majestic-lifesca-413314/) | Vinyl | 0.18 | 0.18 | 43 |
| [**Vector Windows** — Envision Double Glider](https://ela-ecolandscapingassn.org/windows/models/vector-windows-envision-double-glider-414031/) | Vinyl | 0.18 | 0.16 | 69 |
| [**Vector Windows** — Envision Double Hung](https://ela-ecolandscapingassn.org/windows/models/vector-windows-envision-double-hung-414030/) | Vinyl | 0.18 | 0.17 | 69 |
| [**National Vinyl, LLC** — TG/NW3/Destiny/Duratrust/Clarion/Sentinel Awning](https://ela-ecolandscapingassn.org/windows/models/national-vinyl-llc-tg-nw3-destiny-duratrust-clarion-sentinel-awning/) | Vinyl | 0.18 | 0.18 | 73 |

## What other certified series does Seven D Windows and Door LLC produce?

Compare other active Seven D Windows and Door LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [7700/7800 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-casement-picture-window-41405/)

U-Factor 0.14–0.25 · 60 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-casement-picture-window-41405/)

Picture WindowMin U 0.14

### [7700/7800 Picture Window](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-picture-window-414048/)

U-Factor 0.14–0.25 · 46 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-picture-window-414048/)

Sliding Patio DoorMin U 0.16

### [7700/7800 Patio Door](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-patio-door-414055/)

U-Factor 0.16–0.27 · 22 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-patio-door-414055/)

Single SliderMin U 0.16

### [7700/7800 Single Slider](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-single-slider-414051/)

U-Factor 0.16–0.25 · 24 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-single-slider-414051/)

Awning (Projected)Min U 0.17

### [7700/7800 Awning](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-awning-414053/)

U-Factor 0.17–0.27 · 55 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-awning-414053/)

Casement WindowsMin U 0.17

### [7700/7800 Casement](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-casement-414052/)

U-Factor 0.17–0.27 · 55 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/seven-d-windows-and-door-llc-7700-7800-casement-414052/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Seven D Windows and Door LLC 7700/7800 XX Slider appear below.

### How well does 7700/7800 XX Slider by Seven D Windows and Door LLC insulate relative to Window benchmarks?

Built with Vinyl framing in Dual-Slide Horizontal (HSXX) style, Seven D Windows and Door LLC 7700/7800 XX Slider offers 56 Version 7.0 configurations from U 0.18 up to 0.29, posting -0.02 against the Window median of 0.20 with 18 Most Efficient picks.

### Is 7700/7800 XX Slider approved for Northern Zone heating climates?

Cold-climate buyers get 21 compliant Northern packages inside 7700/7800 XX Slider, reaching down to U 0.18. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.29 options.

### What BTU/hr heat transfer results from 7700/7800 XX Slider's 0.18 minimum U-Factor?

Using NFRC SED U-Factor 0.18, a 15 sq ft Dual-Slide Horizontal (HSXX) assembly conducts 108.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-24.0 BTU/hr margin).

### What homeowner profiles are a poor match for Seven D Windows and Door LLC 7700/7800 XX Slider?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 7700/7800 XX Slider options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### How many 7700/7800 XX Slider glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 26 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Seven D Windows and Door LLC 7700/7800 XX Slider, while total line SHGC reaches 0.28 in colder packages.

### Which package tier in 7700/7800 XX Slider holds Most Efficient recognition?

Within 7700/7800 XX Slider, 32.1% (18 of 56) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

### How do the 25C sunset and pre-1978 Lead RRP rules affect 7700/7800 XX Slider?

Any 7700/7800 XX Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How do building inspectors verify 7700/7800 XX Slider glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line SED-A-46 and NFRC ID SED before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Seven D Windows and Door LLC 7700/7800 XX Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)