---
title: "Sierra Pacific Windows Alum Clad Bi-Fold OS Door Specs"
url: https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-alum-clad-bi-fold-os-door-414065/
description: "Sierra Pacific Windows Alum Clad Bi-Fold OS Door (SIE-N-79, Sliding Patio Door, Wood): U-Factor 0.18-0.28, SHGC 0.08-0.39, 1257 options across 4 ENERGY STAR."
---

Door · Wood Frame NFRC SIE · Product Line SIE-N-79 ENERGY STAR Most Efficient Eligible

# Sierra Pacific Windows — Alum Clad Bi-Fold OS Door · Sliding Patio Door

Positioning #75/268 in certified Door, Sierra Pacific Windows Alum Clad Bi-Fold OS Door pairs Wood frame with Metal-Clad Wood sash with 1,257 glazing options rated between 0.08 and 0.39 SHGC across Northern, North-Central, South-Central, Southern. Across 25 certified Sierra Pacific Windows product families, its thermal resistance spans 0.18 to 0.28 U-Factor and the line includes 424 ENERGY STAR Most Efficient packages (33.7% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.18

- **SHGC Range** : 0.08-0.39

- **Certified Options** : 1,257

- **Category Standing** : #75 of 268

## How does Sierra Pacific Windows Alum Clad Bi-Fold OS Door compare thermally against Door peers?

Sierra Pacific Windows Alum Clad Bi-Fold OS Door achieves a 0.18 thermal floor across Door lines, placing #75 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), Alum Clad Bi-Fold OS Door reaches 0.18 on its lowest-conductivity package — #123 of 408 in Wood, tied with 19 others at 0.18, more insulating than 65.2% of Wood lines, top 34.8% (-0.03 vs Wood peers). Pairing NFRC ID SIE across multi-pane fills shifts U-Factor from 0.28 down toward 0.18.

Regional qualification covers Northern, North-Central, South-Central, Southern. 424 configurations meet ENERGY STAR Most Efficient criteria while 905 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors SIE to 2025-08-11 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 108.0 BTU/hr conductive loss (-18.2% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,257 certified glazing combinations for Alum Clad Bi-Fold OS Door (NFRC SIE) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 905 packages (64 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 905 packages (228 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 1,071 packages (197 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 1,071 packages (393 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Pella Corporation** — Architect Series Clad Outswing Door](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-architect-series-clad-outswing-door-413896/) | Wood | 0.18 | 0.09 | 1,221 |
| [**Pella Corporation** — Architect Series Clad Inswing Door](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-architect-series-clad-inswing-door-413898/) | Wood | 0.18 | 0.09 | 1,632 |
| [**Lepage Millwork** — MultiSlide Patio Door (Wood and Clad)](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-multislide-patio-door-wood-and-clad-413520/) | Wood | 0.18 | 0.13 | 132 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Heritage Outswing Door](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-outswing-door-413424/) | Wood | 0.18 | 0.04 | 6,964 |
| [**Vinylmax LLC** — PD3 Patio Door](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-pd3-patio-door-414256/) | Vinyl | 0.18 | 0.06 | 1,217 |

## What other certified series does Sierra Pacific Windows produce?

Compare other active Sierra Pacific Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [Clad Aspen Fixed](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-fixed-414079/)

U-Factor 0.14–0.32 · 1,585 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-fixed-414079/)

Awning (Projected)Min U 0.16

### [Clad Aspen Awning](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-awning-414081/)

U-Factor 0.16–0.32 · 1,620 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-awning-414081/)

Casement WindowsMin U 0.16

### [Clad Aspen Casement](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-casement-414080/)

U-Factor 0.16–0.32 · 1,629 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-casement-414080/)

Picture WindowMin U 0.16

### [Clad Direct Set](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-direct-set-414067/)

U-Factor 0.16–0.32 · 2,962 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-direct-set-414067/)

Picture WindowMin U 0.17

### [Vinyl Direct Set](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-vinyl-direct-set-414078/)

U-Factor 0.17–0.32 · 2,077 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-vinyl-direct-set-414078/)

Picture WindowMin U 0.18

### [H3 2.0 Direct Set](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-h3-2-0-direct-set-414082/)

U-Factor 0.18–0.32 · 1,846 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-h3-2-0-direct-set-414082/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Sierra Pacific Windows Alum Clad Bi-Fold OS Door appear below.

### How efficient is Sierra Pacific Windows Alum Clad Bi-Fold OS Door compared with peer Door models?

Built with Wood framing in Sliding Glass Door (DDSG) style, Sierra Pacific Windows Alum Clad Bi-Fold OS Door offers 1,257 Version 7.0 configurations from U 0.18 up to 0.28, posting -0.03 against the Door median of 0.21 with 424 Most Efficient picks.

### Is Alum Clad Bi-Fold OS Door approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 905 Alum Clad Bi-Fold OS Door packages (U floor 0.18, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

### How does a 3x5 ft Alum Clad Bi-Fold OS Door window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Alum Clad Bi-Fold OS Door at U 0.18 conducts 108.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### Who should NOT choose Sierra Pacific Windows Alum Clad Bi-Fold OS Door for a residential project?

Skip Alum Clad Bi-Fold OS Door if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Alum Clad Bi-Fold OS Door options exceeding U 0.22.

### Does Alum Clad Bi-Fold OS Door meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, Alum Clad Bi-Fold OS Door holds 1,071 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.08 SHGC in cooling climates.

### What glazing share inside Alum Clad Bi-Fold OS Door qualifies as Most Efficient?

Only 424 options out of 1,257 (33.7%) meet tighter Most Efficient U-Factor and SHGC thresholds in Sierra Pacific Windows Alum Clad Bi-Fold OS Door, usually requiring triple-pane or upgraded Low-E coatings.

### Can homeowners claim Form 5695 credits on Sierra Pacific Windows Alum Clad Bi-Fold OS Door in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### Where are NFRC and IGCC identification marks located on Alum Clad Bi-Fold OS Door?

Verify NFRC ID SIE and series SIE-N-79 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Sierra Pacific Windows Alum Clad Bi-Fold OS Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
