title: "Sierra Pacific Windows Clad Aspen Casement Specs (U 0.16)"
url: https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-casement-414080/
description: "Sierra Pacific Windows Clad Aspen Casement (SIE-N-145, Casement Windows, Wood): U-Factor 0.16-0.32, SHGC 0.09-0.43, 1629 options across 4 ENERGY STAR zones."
---

Window · Wood Frame NFRC SIE · Product Line SIE-N-145 ENERGY STAR Most Efficient Eligible

# Sierra Pacific Windows — Clad Aspen Casement · Casement Windows

Sierra Pacific Windows Clad Aspen Casement is a Casement Windows assembly with a Wood frame that reaches a minimum U-Factor of 0.16 across 1,629 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #250 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.09 to 0.43.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.16

- **SHGC Range** : 0.09-0.43

- **Certified Options** : 1,629

- **Category Standing** : #250 of 1,352

## How does Sierra Pacific Windows Clad Aspen Casement compare thermally against Window peers?

Sierra Pacific Windows Clad Aspen Casement achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Clad Aspen Casement is 0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.16-0.32.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 350 configurations meet ENERGY STAR Most Efficient criteria while 303 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.16 U-Factor yields 96.0 BTU/hr transfer (-36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-02-27 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,629 certified glazing combinations for Clad Aspen Casement (NFRC SIE) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 303 packages (140 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 746 packages (279 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 930 packages (208 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 1,359 packages (279 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Marvin** — Ultimate Wood Double Hung Picture 2inch Sash](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-picture-2inch-sash-413559/) | Wood | 0.16 | 0.10 | 1,597 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Heritage Push Out Awning MPL & SPL](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-push-out-awning-mpl-spl-413/) | Wood | 0.16 | 0.08 | 1,730 |
| [**Kolbe and Kolbe Millwork Co., Inc** — VistaLuxe Awning](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-vistaluxe-awning-413456/) | Wood | 0.16 | 0.10 | 1,178 |
| [**Weather Shield Mfg., Inc.** — 8306 / 1309 / 1310 Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8306-1309-1310-direct-set-414354/) | Wood | 0.16 | 0.13 | 1,033 |
| [**Andersen Corporation** — A-Series Specialty Windows - Direct-Set](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-a-series-specialty-windows-direct-set-412965/) | Wood | 0.16 | 0.16 | 2,333 |

## What other certified series does Sierra Pacific Windows produce?

Compare other active Sierra Pacific Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [Clad Aspen Fixed](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-fixed-414079/)

U-Factor 0.14–0.32 · 1,585 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-fixed-414079/)

Awning (Projected)Min U 0.16

### [Clad Aspen Awning](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-awning-414081/)

U-Factor 0.16–0.32 · 1,620 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-awning-414081/)

Picture WindowMin U 0.16

### [Clad Direct Set](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-direct-set-414067/)

U-Factor 0.16–0.32 · 2,962 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-direct-set-414067/)

Picture WindowMin U 0.17

### [Vinyl Direct Set](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-vinyl-direct-set-414078/)

U-Factor 0.17–0.32 · 2,077 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-vinyl-direct-set-414078/)

Sliding Patio DoorMin U 0.18

### [Alum Clad Bi-Fold OS Door](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-alum-clad-bi-fold-os-door-414065/)

U-Factor 0.18–0.28 · 1,257 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-alum-clad-bi-fold-os-door-414065/)

Picture WindowMin U 0.18

### [H3 2.0 Direct Set](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-h3-2-0-direct-set-414082/)

U-Factor 0.18–0.32 · 1,846 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-h3-2-0-direct-set-414082/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Sierra Pacific Windows Clad Aspen Casement appear below.

### What thermal performance numbers separate Sierra Pacific Windows Clad Aspen Casement from peers?

Testing puts Sierra Pacific Windows Clad Aspen Casement at rank #250 of 1,352 Window entries with U 0.16 to 0.32 across 1,629 configurations. Solar heat gain ranges between 0.09 and 0.43 across Northern, North-Central, South-Central, Southern.

### Can homeowners install Clad Aspen Casement in cold Northern ENERGY STAR counties?

Prescriptive Northern compliance covers 303 Clad Aspen Casement packages (U floor 0.16, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

### How does a 3x5 ft Clad Aspen Casement window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.16 U-Factor yields 96.0 BTU/hr conductive transfer (-27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What are the practical limitations of specifying Clad Aspen Casement?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Clad Aspen Casement options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

### How many Clad Aspen Casement glazing packages pass Southern solar-heat rules?

Exactly 1,359 Clad Aspen Casement options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.09 rather than higher 0.43 glass.

### Are all 1,629 Clad Aspen Casement configurations ENERGY STAR Most Efficient?

EPA lists 350 Most Efficient options (21.5% share) inside Sierra Pacific Windows Clad Aspen Casement, out of 1,629 total Version 7.0 entries.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Clad Aspen Casement?

Any Clad Aspen Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How can homeowners confirm delivered Sierra Pacific Windows Clad Aspen Casement units match permits?

Inspectors match the temporary NFRC sticker (U 0.16-0.32, SHGC 0.09-0.43) against permit drawings for line SIE-N-145. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Sierra Pacific Windows Clad Aspen Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)