title: "Sierra Pacific Windows Monument Single Hung - Double Hung"
url: https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-monument-single-hung-double-hung-414068/
description: "Sierra Pacific Windows Monument Single Hung - Double Hung (SIE-N-101, Double Hung, Wood): U-Factor 0.22-0.32, SHGC 0.09-0.44, 1398 options across 4 ENERGY."
---

Window · Wood Frame NFRC SIE · Product Line SIE-N-101 ENERGY STAR Most Efficient Eligible

# Sierra Pacific Windows — Monument Single Hung - Double Hung · Double Hung

Across 25 Sierra Pacific Windows certified families, Monument Single Hung - Double Hung supplies 1,398 Double Hung configurations starting at 0.22 U-Factor and 0.09 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.44 SHGC. Its thermal floor ranks #831 of 1,352 category entries—0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.22

- **SHGC Range** : 0.09-0.44

- **Certified Options** : 1,398

- **Category Standing** : #831 of 1,352

## How does Sierra Pacific Windows Monument Single Hung - Double Hung compare thermally against Window peers?

Sierra Pacific Windows Monument Single Hung - Double Hung achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Sierra Pacific Windows Monument Single Hung - Double Hung standing at #831 of 1,352 certified Window product series, tied with 104 others at 0.22, more insulating than 30.8% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.01 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. 3 configurations meet ENERGY STAR Most Efficient criteria while 15 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors SIE to 2024-02-21 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 132.0 BTU/hr conductive loss (equal to the 0.22 Northern floor).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,398 certified glazing combinations for Monument Single Hung - Double Hung (NFRC SIE) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 15 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 206 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 572 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 1,338 packages (3 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Andersen Corporation** — 400 Series Woodwright® Double-Hung Picture Full-Frame Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-woodwright-double-hung-picture-full/) | Wood | 0.22 | 0.15 | 1,345 |
| [**JELD-WEN, inc.** — Custom Wood Epic Double Hung Picture](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-custom-wood-epic-double-hung-picture-413374/) | Wood | 0.22 | 0.10 | 1,142 |
| [**Marvin** — Ultimate Wood Double Hung Transom](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-transom-413558/) | Wood | 0.22 | 0.11 | 1,687 |
| [**Windsor Windows and Doors** — Revive Clad Pocket Casement Picture](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-revive-clad-pocket-casement-picture-414451/) | Wood | 0.22 | 0.16 | 1,064 |
| [**Andersen Corporation** — 400 Series Specialty Windows - Arch Flexiframe®](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-specialty-windows-arch-flexiframe-41/) | Wood | 0.22 | 0.15 | 1,914 |

## What other certified series does Sierra Pacific Windows produce?

Compare other active Sierra Pacific Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [Clad Aspen Fixed](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-fixed-414079/)

U-Factor 0.14–0.32 · 1,585 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-fixed-414079/)

Awning (Projected)Min U 0.16

### [Clad Aspen Awning](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-awning-414081/)

U-Factor 0.16–0.32 · 1,620 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-awning-414081/)

Casement WindowsMin U 0.16

### [Clad Aspen Casement](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-casement-414080/)

U-Factor 0.16–0.32 · 1,629 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-casement-414080/)

Picture WindowMin U 0.16

### [Clad Direct Set](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-direct-set-414067/)

U-Factor 0.16–0.32 · 2,962 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-direct-set-414067/)

Picture WindowMin U 0.17

### [Vinyl Direct Set](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-vinyl-direct-set-414078/)

U-Factor 0.17–0.32 · 2,077 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-vinyl-direct-set-414078/)

Sliding Patio DoorMin U 0.18

### [Alum Clad Bi-Fold OS Door](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-alum-clad-bi-fold-os-door-414065/)

U-Factor 0.18–0.28 · 1,257 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-alum-clad-bi-fold-os-door-414065/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Sierra Pacific Windows Monument Single Hung - Double Hung appear below.

### How efficient is Sierra Pacific Windows Monument Single Hung - Double Hung compared with peer Window models?

Across 1,398 tested NFRC glazing configurations, Sierra Pacific Windows Monument Single Hung - Double Hung with Wood framing and Double-Hung (VSDH) style reaches a 0.22 minimum U-Factor and 0.09-0.44 SHGC band. It places #831 among 1,352 Window series—more insulating than 30.8%.

### Is Monument Single Hung - Double Hung approved for Northern Zone heating climates?

Yes, 15 packages satisfy Northern ENERGY STAR Version 7.0 rules in Monument Single Hung - Double Hung. Pairing multi-pane insulation down to 0.22 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### What conductive BTU/hr difference separates Monument Single Hung - Double Hung from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Monument Single Hung - Double Hung at U 0.22 conducts 132.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### When should a buyer skip Sierra Pacific Windows Monument Single Hung - Double Hung and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Monument Single Hung - Double Hung options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### Does Monument Single Hung - Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 1,338 Monument Single Hung - Double Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.09 rather than higher 0.44 glass.

### Which package tier in Monument Single Hung - Double Hung holds Most Efficient recognition?

No. Exactly 3 of 1,398 configurations (0.2%) earn ENERGY STAR Most Efficient status in Monument Single Hung - Double Hung; the remaining standard v7.0 options pass base zone limits only.

### Can homeowners claim Form 5695 credits on Sierra Pacific Windows Monument Single Hung - Double Hung in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Sierra Pacific Windows upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### Where are NFRC and IGCC identification marks located on Monument Single Hung - Double Hung?

Match the NFRC thermal sticker for code SIE and line SIE-N-101 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Sierra Pacific Windows Monument Single Hung - Double Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)