---
title: "Slocomb Windows and Doors 300 Series Casement Specs"
url: https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-300-series-casement-414100/
description: "Slocomb Windows and Doors 300 Series Casement (SLC-K-6, Casement Windows, Vinyl): U-Factor 0.16-0.28, SHGC 0.14-0.27, 135 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC SLC · Product Line SLC-K-6 ENERGY STAR Most Efficient Eligible

# Slocomb Windows and Doors, Inc — 300 Series Casement · Casement Windows

EPA ENERGY STAR Version 7.0 certifies 135 variants inside Slocomb Windows and Doors, Inc 300 Series Casement, combining Vinyl frame construction with U-Factors spanning 0.16 to 0.28 and SHGC 0.14 to 0.27. Qualifying for Northern, North-Central, South-Central, Southern, this Casement Windows family places #250 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.16

- **SHGC Range** : 0.14-0.27

- **Certified Options** : 135

- **Category Standing** : #250 of 1,352

## How does Slocomb Windows and Doors, Inc 300 Series Casement compare thermally against Window peers?

Slocomb Windows and Doors, Inc 300 Series Casement achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 300 Series Casement reaches 0.16 on its lowest-conductivity package — #170 of 1,009 in Vinyl, tied with 100 others at 0.16, more insulating than 73.2% of Vinyl lines, top 26.8% (-0.03 vs Vinyl peers). Pairing NFRC ID SLC across multi-pane fills shifts U-Factor from 0.28 down toward 0.16.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 69 configurations meet ENERGY STAR Most Efficient criteria while 60 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-02-08 and FENSTAR license 2023-03-23 inside EPA Version 7.0 tables. Heat transfer computes to 96.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 135 certified glazing combinations for 300 Series Casement (NFRC SLC) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 60 packages (14 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 118 packages (42 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 110 packages (42 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 110 packages (69 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**NT Window, Inc.** — C150 - Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c150-casement-picture-window-413844/) | Vinyl | 0.16 | 0.13 | 140 |
| [**Vytex Corporation** — 3300 Casement](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-casement-414303/) | Vinyl | 0.16 | 0.11 | 126 |
| [**Mathews Brothers Company** — Sanford Hills Double Hung Picture Window](https://ela-ecolandscapingassn.org/windows/models/mathews-brothers-company-sanford-hills-double-hung-picture-window-41/) | Vinyl | 0.16 | 0.21 | 156 |
| [**Crystal Window and Door Systems, Ltd.** — 211 Series Fixed Window](https://ela-ecolandscapingassn.org/windows/models/crystal-window-and-door-systems-ltd-211-series-fixed-window-413118/) | Vinyl | 0.16 | 0.18 | 157 |
| [**OKNA Windows & Doors Mfg** — CA700/4700 Casement](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-ca700-4700-casement-413864/) | Vinyl | 0.16 | 0.14 | 111 |

## What other certified series does Slocomb Windows and Doors, Inc produce?

Compare other active Slocomb Windows and Doors, Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.12

### [400/500 Series Picture Window](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-400-500-series-picture-window-414097/)

U-Factor 0.12–0.29 · 157 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-400-500-series-picture-window-414097/)

Picture WindowMin U 0.13

### [100 Series Picture Window](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-100-series-picture-window-414102/)

U-Factor 0.13–0.28 · 158 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-100-series-picture-window-414102/)

Double HungMin U 0.15

### [400/500 Series Double Hung](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-400-500-series-double-hung-414096/)

U-Factor 0.15–0.29 · 322 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-400-500-series-double-hung-414096/)

Double SliderMin U 0.16

### [100/200 Series Double Hung](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-100-200-series-double-hung-414099/)

U-Factor 0.16–0.28 · 512 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-100-200-series-double-hung-414099/)

Awning (Projected)Min U 0.16

### [300 Series Awning](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-300-series-awning-414101/)

U-Factor 0.16–0.28 · 134 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-300-series-awning-414101/)

Double SliderMin U 0.16

### [400/500 Series Double Slider](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-400-500-series-double-slider-414098/)

U-Factor 0.16–0.30 · 212 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-400-500-series-double-slider-414098/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Slocomb Windows and Doors, Inc 300 Series Casement appear below.

### What thermal performance numbers separate Slocomb Windows and Doors, Inc 300 Series Casement from peers?

Built with Vinyl framing in Casement Single-Vent (CSSV) style, Slocomb Windows and Doors, Inc 300 Series Casement offers 135 Version 7.0 configurations from U 0.16 up to 0.28, posting -0.04 against the Window median of 0.20 with 69 Most Efficient picks.

### Is 300 Series Casement approved for Northern Zone heating climates?

Yes. 60 packages in Slocomb Windows and Doors, Inc 300 Series Casement clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.28.

### How much winter heat loss does 300 Series Casement conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 96.0 BTU/hr on 300 Series Casement's lowest-U package (0.16), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

### Which situations make 300 Series Casement the wrong window or door choice?

Skip 300 Series Casement if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 300 Series Casement options exceeding U 0.22.

### Can you install Slocomb Windows and Doors, Inc 300 Series Casement in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 110 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Slocomb Windows and Doors, Inc 300 Series Casement, while total line SHGC reaches 0.27 in colder packages.

### Does 300 Series Casement carry EPA Most Efficient certification across its lineup?

Only 69 options out of 135 (51.1%) meet tighter Most Efficient U-Factor and SHGC thresholds in Slocomb Windows and Doors, Inc 300 Series Casement, usually requiring triple-pane or upgraded Low-E coatings.

### Do 2026 300 Series Casement installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 300 Series Casement installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How do building inspectors verify 300 Series Casement glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.16-0.28, SHGC 0.14-0.27) against permit drawings for line SLC-K-6. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Slocomb Windows and Doors, Inc 300 Series Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
