title: "Slocomb Windows and Doors 400/500 Series Picture Window"
url: https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-400-500-series-picture-window-414097/
description: "Slocomb Windows and Doors 400/500 Series Picture Window (SLC-K-3, Picture Window, Vinyl): U-Factor 0.12-0.29, SHGC 0.15-0.30, 157 options across 4 ENERGY."
---

Window · Vinyl Frame NFRC SLC · Product Line SLC-K-3 ENERGY STAR Most Efficient Eligible

# Slocomb Windows and Doors, Inc — 400/500 Series Picture Window · Picture Window

With a minimum U-Factor of 0.12—-0.08 compared against the 0.20 Window median—Slocomb Windows and Doors, Inc 400/500 Series Picture Window spans 157 tested options across Northern, North-Central, South-Central, Southern up to 0.29 U-Factor. Carrying NFRC CPD code SLC, the Vinyl assembly includes 75 ENERGY STAR Most Efficient packages (47.8% of line) and offers SHGC packages between 0.15 and 0.30.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.12

- **SHGC Range** : 0.15-0.30

- **Certified Options** : 157

- **Category Standing** : #19 of 1,352

## How does Slocomb Windows and Doors, Inc 400/500 Series Picture Window compare thermally against Window peers?

Slocomb Windows and Doors, Inc 400/500 Series Picture Window achieves a 0.12 thermal floor across Window lines, placing #19 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 400/500 Series Picture Window reaches 0.12 on its lowest-conductivity package — #8 of 1,009 in Vinyl, tied with 8 others at 0.12, more insulating than 98.4% of Vinyl lines, top 1.6% (-0.07 vs Vinyl peers). Pairing NFRC ID SLC across multi-pane fills shifts U-Factor from 0.29 down toward 0.12.

Mapping NFRC SHGC values (0.15 to 0.30) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 75 configurations meet ENERGY STAR Most Efficient criteria while 82 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors SLC to 2024-02-08 certification (FENSTAR issued 2023-03-23). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 72.0 BTU/hr conductive loss (-45.5% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 157 certified glazing combinations for 400/500 Series Picture Window (NFRC SLC) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 82 packages (41 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 144 packages (64 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 93 packages (46 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 100 packages (57 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.12 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Alpen HPP, LLC dba Alpen High Performance Products** — Tyrol Tilt Turn](https://ela-ecolandscapingassn.org/windows/models/alpen-hpp-llc-dba-alpen-high-performance-products-tyrol-tilt-turn-41/) | Vinyl | 0.12 | 0.15 | 120 |
| [**Paradigm Window Solutions** — 8361 Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-8361-fixed-casement-413977/) | Vinyl | 0.12 | 0.15 | 648 |
| [**Euroline Windows Inc.** — Energeto Neo 76 Small Picture Window](https://ela-ecolandscapingassn.org/windows/models/euroline-windows-inc-energeto-neo-76-small-picture-window-413022/) | Vinyl | 0.12 | 0.16 | 1,028 |
| [**Innotech Windows & Doors Inc.** — Defender 88PH+ XI Fixed](https://ela-ecolandscapingassn.org/windows/models/innotech-windows-doors-inc-defender-88ph-xi-fixed-413335/) | Vinyl | 0.12 | 0.14 | 5,838 |
| [**Innotech Windows & Doors Inc.** — Defender 88PH+ XI Dual Action](https://ela-ecolandscapingassn.org/windows/models/innotech-windows-doors-inc-defender-88ph-xi-dual-action-413336/) | Vinyl | 0.12 | 0.12 | 5,850 |

## What other certified series does Slocomb Windows and Doors, Inc produce?

Compare other active Slocomb Windows and Doors, Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [100 Series Picture Window](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-100-series-picture-window-414102/)

U-Factor 0.13–0.28 · 158 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-100-series-picture-window-414102/)

Double HungMin U 0.15

### [400/500 Series Double Hung](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-400-500-series-double-hung-414096/)

U-Factor 0.15–0.29 · 322 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-400-500-series-double-hung-414096/)

Double SliderMin U 0.16

### [100/200 Series Double Hung](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-100-200-series-double-hung-414099/)

U-Factor 0.16–0.28 · 512 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-100-200-series-double-hung-414099/)

Awning (Projected)Min U 0.16

### [300 Series Awning](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-300-series-awning-414101/)

U-Factor 0.16–0.28 · 134 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-300-series-awning-414101/)

Casement WindowsMin U 0.16

### [300 Series Casement](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-300-series-casement-414100/)

U-Factor 0.16–0.28 · 135 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-300-series-casement-414100/)

Double SliderMin U 0.16

### [400/500 Series Double Slider](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-400-500-series-double-slider-414098/)

U-Factor 0.16–0.30 · 212 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-400-500-series-double-slider-414098/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Slocomb Windows and Doors, Inc 400/500 Series Picture Window appear below.

### How well does 400/500 Series Picture Window by Slocomb Windows and Doors, Inc insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 157 configurations for Slocomb Windows and Doors, Inc 400/500 Series Picture Window covering Northern, North-Central, South-Central, Southern, dropping down to U 0.12 versus a 0.20 Window median. Only 75 options earn Most Efficient status.

### Can homeowners install 400/500 Series Picture Window in cold Northern ENERGY STAR counties?

Yes, 82 packages satisfy Northern ENERGY STAR Version 7.0 rules in 400/500 Series Picture Window. Pairing multi-pane insulation down to 0.12 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How does a 3x5 ft 400/500 Series Picture Window window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 72.0 BTU/hr on 400/500 Series Picture Window's lowest-U package (0.12), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.29 transfer proportionally more energy.

### When should a buyer skip Slocomb Windows and Doors, Inc 400/500 Series Picture Window and compare alternatives?

Do not specify 400/500 Series Picture Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 400/500 Series Picture Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Is 400/500 Series Picture Window suitable for sunbelt cooling-dominated homes?

Exactly 100 400/500 Series Picture Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.15 rather than higher 0.30 glass.

### Are all 157 400/500 Series Picture Window configurations ENERGY STAR Most Efficient?

EPA lists 75 Most Efficient options (47.8% share) inside Slocomb Windows and Doors, Inc 400/500 Series Picture Window, out of 157 total Version 7.0 entries.

### What federal compliance checks govern 2026 400/500 Series Picture Window window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 400/500 Series Picture Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How do you cross-check NFRC SLC and product line SLC-K-3 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code SLC and product line SLC-K-3, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Slocomb Windows and Doors, Inc 400/500 Series Picture Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)