title: "Soft-Lite CPW Casement Picture Window Specs (U 0.13)"
url: https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-cpw-casement-picture-window-414111/
description: "Soft-Lite CPW Casement Picture Window (SLL-A-88, Picture Window, Vinyl): U-Factor 0.13-0.27, SHGC 0.13-0.38, 1003 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC SLL · Product Line SLL-A-88 ENERGY STAR Most Efficient Eligible

# Soft-Lite, LLC — CPW Casement Picture Window · Picture Window

EPA ENERGY STAR Version 7.0 certifies 1,003 variants inside Soft-Lite, LLC CPW Casement Picture Window, combining Vinyl frame construction with U-Factors spanning 0.13 to 0.27 and SHGC 0.13 to 0.38. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #36 of 1,352 among 1,352 Window families and posts 0.06 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.13

- **SHGC Range** : 0.13-0.38

- **Certified Options** : 1,003

- **Category Standing** : #36 of 1,352

## How does Soft-Lite, LLC CPW Casement Picture Window compare thermally against Window peers?

Soft-Lite, LLC CPW Casement Picture Window achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across CPW Casement Picture Window spans 1,003 NFRC test records (SLL), ranking #36 of 1,352 Window families (tied with 35 others at 0.13, more insulating than 94.7% of Window lines, top 5.3%). Its 0.13 thermal floor compares at -0.06 against the Vinyl median (0.19).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 401 configurations meet ENERGY STAR Most Efficient criteria while 426 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.13 U-Factor yields 78.0 BTU/hr transfer (-54.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-01-17 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,003 certified glazing combinations for CPW Casement Picture Window (NFRC SLL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 426 packages (203 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 880 packages (384 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 624 packages (257 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 624 packages (274 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Harvey Industries, Inc.** — Axio Direct Set Fixed Window](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-axio-direct-set-fixed-window-413307/) | Vinyl | 0.13 | 0.17 | 725 |
| [**ProVia LLC** — New Aspect/Endure Picture Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-new-aspect-endure-picture-window-413957/) | Vinyl | 0.13 | 0.14 | 404 |
| [**ProVia LLC** — Vinyl Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-vinyl-casement-picture-window-413953/) | Vinyl | 0.13 | 0.06 | 365 |
| [**Advanced Window Corp.** — EU 76 Septem Fixed](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-fixed-412865/) | Vinyl | 0.13 | 0.15 | 300 |
| [**North Star Manufacturing (London) Ltd.** — 1071 Fixed](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1071-fixed-413828/) | Vinyl | 0.13 | 0.17 | 205 |

## What other certified series does Soft-Lite, LLC produce?

Compare other active Soft-Lite, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [CPWL Casement Picture Window Low Profile](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-cpwl-casement-picture-window-low-profile-414112/)

U-Factor 0.13–0.27 · 925 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-cpwl-casement-picture-window-low-profile-414112/)

Awning (Projected)Min U 0.15

### [Awning](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-awning-414110/)

U-Factor 0.15–0.27 · 1,020 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-awning-414110/)

Casement WindowsMin U 0.15

### [Casement](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-casement-414109/)

U-Factor 0.15–0.27 · 1,066 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-casement-414109/)

Sliding Patio DoorMin U 0.17

### [Kingsroyal Patio Door](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-kingsroyal-patio-door-414108/)

U-Factor 0.17–0.28 · 485 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-kingsroyal-patio-door-414108/)

Double HungMin U 0.19

### [Elements DH20 Double Hung](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-elements-dh20-double-hung-414104/)

U-Factor 0.19–0.27 · 68 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-elements-dh20-double-hung-414104/)

Double HungMin U 0.19

### [Imperial Elite DH12E](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-imperial-elite-dh12e-414115/)

U-Factor 0.19–0.27 · 68 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-imperial-elite-dh12e-414115/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Soft-Lite, LLC CPW Casement Picture Window appear below.

### What U-Factor and SHGC range does Soft-Lite, LLC CPW Casement Picture Window achieve?

Testing puts Soft-Lite, LLC CPW Casement Picture Window at rank #36 of 1,352 Window entries with U 0.13 to 0.27 across 1,003 configurations. Solar heat gain ranges between 0.13 and 0.38 across Northern, North-Central, South-Central, Southern.

### How does Soft-Lite, LLC CPW Casement Picture Window satisfy Version 7.0 Northern criteria?

Yes. 426 packages in Soft-Lite, LLC CPW Casement Picture Window clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.27.

### How does a 3x5 ft CPW Casement Picture Window window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), CPW Casement Picture Window at U 0.13 conducts 78.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### Who should NOT choose Soft-Lite, LLC CPW Casement Picture Window for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on CPW Casement Picture Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Is CPW Casement Picture Window suitable for sunbelt cooling-dominated homes?

Across Northern, North-Central, South-Central, Southern, 624 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Soft-Lite, LLC CPW Casement Picture Window, while total line SHGC reaches 0.38 in colder packages.

### What glazing share inside CPW Casement Picture Window qualifies as Most Efficient?

Only 401 options out of 1,003 (40.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in Soft-Lite, LLC CPW Casement Picture Window, usually requiring triple-pane or upgraded Low-E coatings.

### Do 2026 CPW Casement Picture Window installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current CPW Casement Picture Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How can homeowners confirm delivered Soft-Lite, LLC CPW Casement Picture Window units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line SLL-A-88 and NFRC ID SLL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Soft-Lite, LLC CPW Casement Picture Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)