title: "Specialty Wholesale Supply 1001/1005/1006 Patio Door Specs"
url: https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-1001-1005-1006-patio-door-413549/
description: "Specialty Wholesale Supply 1001/1005/1006 Patio Door (MAK-K-34, Sliding Patio Door, Vinyl): U-Factor 0.25-0.28, SHGC 0.07-0.27, 8 options across 4 ENERGY."
---

Door · Vinyl Frame NFRC MAK · Product Line MAK-K-34

# Specialty Wholesale Supply — 1001/1005/1006 Patio Door · Sliding Patio Door

With a minimum U-Factor of 0.25—+0.04 compared against the 0.21 Door median—Specialty Wholesale Supply 1001/1005/1006 Patio Door spans 8 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code MAK, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.07 and 0.27.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.25

- **SHGC Range** : 0.07-0.27

- **Certified Options** : 8

- **Category Standing** : #216 of 268

## How does Specialty Wholesale Supply 1001/1005/1006 Patio Door compare thermally against Door peers?

Specialty Wholesale Supply 1001/1005/1006 Patio Door achieves a 0.25 thermal floor across Door lines, placing #216 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 9 certified Specialty Wholesale Supply series, this Sliding Patio Door offers a 0.03 U-Factor adjustment span between 0.28 entry options and 0.25 top-performing glazing. Category standing is #216/268 (tied with 16 others at 0.25, more insulating than 13.4% of Door lines).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 3 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors MAK to 2025-05-13 certification (FENSTAR issued 2018-02-20). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 150.0 BTU/hr conductive loss (+13.6% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 8 certified glazing combinations for 1001/1005/1006 Patio Door (NFRC MAK) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 3 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 3 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 5 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 5 packages (0 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Skyreach Group Inc.** — PD02 Door](https://ela-ecolandscapingassn.org/windows/models/skyreach-group-inc-pd02-door-414057/) | Vinyl | 0.25 | 0.21 | 2 |
| [**Anlin Industries** — Malibu/Monte Verde/Bayview/Extreme Narrow and Wide Style Sliding Patio Door](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-malibu-monte-verde-bayview-extreme-narrow-and-wide/) | Vinyl | 0.25 | 0.10 | 63 |
| [**Krestmark Industries L. P.** — 900 Sliding Patio Door](https://ela-ecolandscapingassn.org/windows/models/krestmark-industries-l-p-900-sliding-patio-door-413509/) | Vinyl | 0.25 | 0.15 | 81 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Forgent Complementary Multislide Door](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-complementary-multislide-doo/) | Vinyl | 0.25 | 0.10 | 90 |
| [**Marvin** — Essential Sliding Patio Door](https://ela-ecolandscapingassn.org/windows/models/marvin-essential-sliding-patio-door-413582/) | Fiberglass | 0.25 | 0.20 | 36 |

## What other certified series does Specialty Wholesale Supply produce?

Compare other active Specialty Wholesale Supply certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Swinging Entry Door (Single)Min U 0.13

### [Wood Edge Steel Entry/Patio Door](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-wood-edge-steel-entry-patio-door-413552/)

U-Factor 0.13–0.28 · 76,045 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-wood-edge-steel-entry-patio-door-413552/)

Swinging Entry Door (Single)Min U 0.15

### [Fiberglass Entry/Patio Door](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-fiberglass-entry-patio-door-413550/)

U-Factor 0.15–0.28 · 242,982 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-fiberglass-entry-patio-door-413550/)

SideliteMin U 0.15

### [Fiberglass Sidelite](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-fiberglass-sidelite-413551/)

U-Factor 0.15–0.28 · 319,127 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-fiberglass-sidelite-413551/)

SideliteMin U 0.15

### [Wood Edge Steel Sidelite](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-wood-edge-steel-sidelite-413553/)

U-Factor 0.15–0.28 · 82,347 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-wood-edge-steel-sidelite-413553/)

Swinging Entry Door (Single)Min U 0.16

### [Metal Edge/Steel Entry Door](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-metal-edge-steel-entry-door-413554/)

U-Factor 0.16–0.28 · 64,485 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-metal-edge-steel-entry-door-413554/)

Casement WindowsMin U 0.19

### [7000/7500 TrustGard Casement](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-7000-7500-trustgard-casement-413547/)

U-Factor 0.19–0.32 · 327 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-7000-7500-trustgard-casement-413547/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Specialty Wholesale Supply 1001/1005/1006 Patio Door appear below.

### How well does 1001/1005/1006 Patio Door by Specialty Wholesale Supply insulate relative to Door benchmarks?

EPA ENERGY STAR v7.0 records 8 configurations for Specialty Wholesale Supply 1001/1005/1006 Patio Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

### Can homeowners install 1001/1005/1006 Patio Door in cold Northern ENERGY STAR counties?

While Specialty Wholesale Supply 1001/1005/1006 Patio Door misses the <= 0.22 prescriptive mark (floor U 0.25), 3 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

### How does a 3x5 ft 1001/1005/1006 Patio Door window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 1001/1005/1006 Patio Door at U 0.25 conducts 150.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### When should a buyer skip Specialty Wholesale Supply 1001/1005/1006 Patio Door and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1001/1005/1006 Patio Door options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Can you install Specialty Wholesale Supply 1001/1005/1006 Patio Door in Southern or South-Central zones?

Exactly 5 1001/1005/1006 Patio Door options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.07 rather than higher 0.27 glass.

### Does 1001/1005/1006 Patio Door carry EPA Most Efficient certification across its lineup?

All 8 1001/1005/1006 Patio Door listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

### Can homeowners claim Form 5695 credits on Specialty Wholesale Supply 1001/1005/1006 Patio Door in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Specialty Wholesale Supply upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### What permanent glass etch marks verify 1001/1005/1006 Patio Door after sticker removal?

Verify NFRC ID MAK and series MAK-K-34 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Specialty Wholesale Supply 1001/1005/1006 Patio Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)