---
title: "Specialty Wholesale Supply 1100/1200/1300 Corsair Patio"
url: https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-1100-1200-1300-corsair-patio-door-413555/
description: "Specialty Wholesale Supply 1100/1200/1300 Corsair Patio Door (MAK-K-45, Sliding Patio Door, Vinyl): U-Factor 0.23-0.28, SHGC 0.07-0.25, 25 options across 4."
---

Door · Vinyl Frame NFRC MAK · Product Line MAK-K-45

# Specialty Wholesale Supply — 1100/1200/1300 Corsair Patio Door · Sliding Patio Door

EPA ENERGY STAR Version 7.0 certifies 25 variants inside Specialty Wholesale Supply 1100/1200/1300 Corsair Patio Door, combining Vinyl frame construction with U-Factors spanning 0.23 to 0.28 and SHGC 0.07 to 0.25. Qualifying for Northern, North-Central, South-Central, Southern, this Sliding Patio Door family places #162 of 268 among 268 Door families and posts 0.04 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.07-0.25

- **Certified Options** : 25

- **Category Standing** : #162 of 268

## How does Specialty Wholesale Supply 1100/1200/1300 Corsair Patio Door compare thermally against Door peers?

Specialty Wholesale Supply 1100/1200/1300 Corsair Patio Door achieves a 0.23 thermal floor across Door lines, placing #162 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 268 ENERGY STAR v7.0 Door lines places Specialty Wholesale Supply 1100/1200/1300 Corsair Patio Door at rank #162 of 268 (tied with 36 others at 0.23, more insulating than 26.1% of Door lines; cohort median 0.21). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.07-0.25 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 24 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2025-04-23 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 25 certified glazing combinations for 1100/1200/1300 Corsair Patio Door (NFRC MAK) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 24 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 24 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 23 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 23 packages (0 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Hometime Windows & Doors** — 356 Patio Door](https://ela-ecolandscapingassn.org/windows/models/hometime-windows-doors-356-patio-door-413312/) | Vinyl | 0.23 | 0.14 | 30 |
| [**Vector Windows** — Full View / Full View Elite Slider Door](https://ela-ecolandscapingassn.org/windows/models/vector-windows-full-view-full-view-elite-slider-door-414023/) | Vinyl | 0.23 | 0.20 | 56 |
| [**Magnolia Window and Door** — 5957 Patio Door](https://ela-ecolandscapingassn.org/windows/models/magnolia-window-and-door-5957-patio-door-413542/) | Vinyl | 0.23 | 0.16 | 104 |
| [**WeatherBarr Windows and Doors** — Pinnacle Patio Door](https://ela-ecolandscapingassn.org/windows/models/weatherbarr-windows-and-doors-pinnacle-patio-door-413289/) | Vinyl | 0.23 | 0.16 | 126 |
| [**Gerkin Windows and Doors** — 4400 Patio Door](https://ela-ecolandscapingassn.org/windows/models/gerkin-windows-and-doors-4400-patio-door-413264/) | Vinyl | 0.23 | 0.09 | 179 |

## What other certified series does Specialty Wholesale Supply produce?

Compare other active Specialty Wholesale Supply certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Swinging Entry Door (Single)Min U 0.13

### [Wood Edge Steel Entry/Patio Door](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-wood-edge-steel-entry-patio-door-413552/)

U-Factor 0.13–0.28 · 76,045 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-wood-edge-steel-entry-patio-door-413552/)

Swinging Entry Door (Single)Min U 0.15

### [Fiberglass Entry/Patio Door](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-fiberglass-entry-patio-door-413550/)

U-Factor 0.15–0.28 · 242,982 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-fiberglass-entry-patio-door-413550/)

SideliteMin U 0.15

### [Fiberglass Sidelite](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-fiberglass-sidelite-413551/)

U-Factor 0.15–0.28 · 319,127 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-fiberglass-sidelite-413551/)

SideliteMin U 0.15

### [Wood Edge Steel Sidelite](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-wood-edge-steel-sidelite-413553/)

U-Factor 0.15–0.28 · 82,347 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-wood-edge-steel-sidelite-413553/)

Swinging Entry Door (Single)Min U 0.16

### [Metal Edge/Steel Entry Door](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-metal-edge-steel-entry-door-413554/)

U-Factor 0.16–0.28 · 64,485 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-metal-edge-steel-entry-door-413554/)

Casement WindowsMin U 0.19

### [7000/7500 TrustGard Casement](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-7000-7500-trustgard-casement-413547/)

U-Factor 0.19–0.32 · 327 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-7000-7500-trustgard-casement-413547/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Specialty Wholesale Supply 1100/1200/1300 Corsair Patio Door appear below.

### How well does 1100/1200/1300 Corsair Patio Door by Specialty Wholesale Supply insulate relative to Door benchmarks?

Testing puts Specialty Wholesale Supply 1100/1200/1300 Corsair Patio Door at rank #162 of 268 Door entries with U 0.23 to 0.28 across 25 configurations. Solar heat gain ranges between 0.07 and 0.25 across Northern, North-Central, South-Central, Southern.

### Can homeowners install 1100/1200/1300 Corsair Patio Door in cold Northern ENERGY STAR counties?

Prescriptive Northern approval ends at U <= 0.22, above 1100/1200/1300 Corsair Patio Door's 0.23 minimum. However, 24 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

### What conductive BTU/hr difference separates 1100/1200/1300 Corsair Patio Door from the 0.22 Northern rule?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 138.0 BTU/hr on 1100/1200/1300 Corsair Patio Door's lowest-U package (0.23), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

### Which situations make 1100/1200/1300 Corsair Patio Door the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 1100/1200/1300 Corsair Patio Door options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

### How many 1100/1200/1300 Corsair Patio Door glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 23 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Specialty Wholesale Supply 1100/1200/1300 Corsair Patio Door, while total line SHGC reaches 0.25 in colder packages.

### Which package tier in 1100/1200/1300 Corsair Patio Door holds Most Efficient recognition?

No. Zero of the 25 configurations in Specialty Wholesale Supply 1100/1200/1300 Corsair Patio Door hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

### Do 2026 1100/1200/1300 Corsair Patio Door installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Specialty Wholesale Supply upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How can homeowners confirm delivered Specialty Wholesale Supply 1100/1200/1300 Corsair Patio Door units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line MAK-K-45 and NFRC ID MAK before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Specialty Wholesale Supply 1100/1200/1300 Corsair Patio Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
