---
title: "Taylors Window and Screen 1800/1830 RR/NC Single Hung"
url: https://ela-ecolandscapingassn.org/windows/models/taylors-window-and-screen-inc-1800-1830-rr-nc-single-hung-414201/
description: "Taylors Window and Screen 1800/1830 RR/NC Single Hung (TWS-K-13, Single Hung, Vinyl): U-Factor 0.24-0.28, SHGC 0.18-0.22, 12 options across 3 ENERGY STAR."
---

Window · Vinyl Frame NFRC TWS · Product Line TWS-K-13

# Taylors Window and Screen, Inc. — 1800/1830 RR/NC Single Hung · Single Hung

Positioning #1,034/1,352 in certified Window, Taylors Window and Screen, Inc. 1800/1830 RR/NC Single Hung pairs Vinyl frame construction with 12 glazing options rated between 0.18 and 0.22 SHGC across North-Central, South-Central, Southern. Across 9 certified Taylors Window and Screen, Inc. product families, its thermal resistance spans 0.24 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.24

- **SHGC Range** : 0.18-0.22

- **Certified Options** : 12

- **Category Standing** : #1,034 of 1,352

## How does Taylors Window and Screen, Inc. 1800/1830 RR/NC Single Hung compare thermally against Window peers?

Taylors Window and Screen, Inc. 1800/1830 RR/NC Single Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 1800/1830 RR/NC Single Hung reaches 0.24 on its lowest-conductivity package — #798 of 1,009 in Vinyl, tied with 108 others at 0.24, more insulating than 10.2% of Vinyl lines (+0.05 vs Vinyl peers). Pairing NFRC ID TWS across multi-pane fills shifts U-Factor from 0.28 down toward 0.24.

Evaluating climate compliance across North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.18 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.24 U-Factor yields 144.0 BTU/hr transfer (+12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-02-21 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 12 certified glazing combinations for 1800/1830 RR/NC Single Hung (NFRC TWS) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 4 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 12 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 12 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Thermo-Twin Industries, Inc.** — S-700/731 Welded Slider](https://ela-ecolandscapingassn.org/windows/models/thermo-twin-industries-inc-s-700-731-welded-slider-414169/) | Vinyl | 0.24 | 0.15 | 17 |
| [**KP Building Products Limited** — 3030/3530 Single Hung](https://ela-ecolandscapingassn.org/windows/models/kp-building-products-limited-3030-3530-single-hung-413243/) | Vinyl | 0.24 | 0.19 | 4 |
| [**Elevate Windows and Doors LLC** — Inspire/Inspire Plus/Inspire Star/Inspire Star Plus Picture](https://ela-ecolandscapingassn.org/windows/models/elevate-windows-and-doors-llc-inspire-inspire-plus-inspire-star-insp/) | Vinyl | 0.24 | 0.20 | 22 |
| [**California Deluxe Windows Industries, Inc.** — S-3505 Double Slider](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3505-double-slider-413097/) | Vinyl | 0.24 | 0.11 | 28 |
| [**Paradigm Window Solutions** — 500/5000 Double Hung](https://ela-ecolandscapingassn.org/windows/models/paradigm-window-solutions-500-5000-double-hung-413978/) | Vinyl | 0.24 | 0.22 | 28 |

## What other certified series does Taylors Window and Screen, Inc. produce?

Compare other active Taylors Window and Screen, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.22

### [1800/1830 RR/NC Picture Window](https://ela-ecolandscapingassn.org/windows/models/taylors-window-and-screen-inc-1800-1830-rr-nc-picture-window-414200/)

U-Factor 0.22–0.26 · 12 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/taylors-window-and-screen-inc-1800-1830-rr-nc-picture-window-414200/)

Picture WindowMin U 0.22

### [7000/8000 Series Picture Window](https://ela-ecolandscapingassn.org/windows/models/taylors-window-and-screen-inc-7000-8000-series-picture-window-414198/)

U-Factor 0.22–0.26 · 14 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/taylors-window-and-screen-inc-7000-8000-series-picture-window-414198/)

Picture WindowMin U 0.23

### [8501 NC/Repl Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/taylors-window-and-screen-inc-8501-nc-repl-casement-picture-window-4/)

U-Factor 0.23–0.28 · 18 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/taylors-window-and-screen-inc-8501-nc-repl-casement-picture-window-4/)

Single SliderMin U 0.24

### [1800/1830 RR/NC OX Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/taylors-window-and-screen-inc-1800-1830-rr-nc-ox-horizontal-slider-4/)

U-Factor 0.24–0.28 · 12 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/taylors-window-and-screen-inc-1800-1830-rr-nc-ox-horizontal-slider-4/)

Casement WindowsMin U 0.24

### [8501 Casement](https://ela-ecolandscapingassn.org/windows/models/taylors-window-and-screen-inc-8501-casement-414203/)

U-Factor 0.24–0.28 · 21 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/taylors-window-and-screen-inc-8501-casement-414203/)

Sliding Patio DoorMin U 0.24

### [900 Series Patio Door](https://ela-ecolandscapingassn.org/windows/models/taylors-window-and-screen-inc-900-series-patio-door-414199/)

U-Factor 0.24–0.28 · 18 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/taylors-window-and-screen-inc-900-series-patio-door-414199/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Taylors Window and Screen, Inc. 1800/1830 RR/NC Single Hung appear below.

### What U-Factor and SHGC range does Taylors Window and Screen, Inc. 1800/1830 RR/NC Single Hung achieve?

EPA ENERGY STAR v7.0 records 12 configurations for Taylors Window and Screen, Inc. 1800/1830 RR/NC Single Hung covering North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

### Which glazing options in Taylors Window and Screen, Inc. 1800/1830 RR/NC Single Hung meet Northern climate limits?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.24). Focus on North-Central, South-Central, Southern glazing applications where SHGC 0.18-0.22 manages cooling loads.

### How much winter heat loss does 1800/1830 RR/NC Single Hung conduct across a 15 sq ft opening?

At U 0.24, a standard 3x5 ft (15 sq ft) 1800/1830 RR/NC Single Hung opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.

### When should a buyer skip Taylors Window and Screen, Inc. 1800/1830 RR/NC Single Hung and compare alternatives?

Do not specify 1800/1830 RR/NC Single Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 1800/1830 RR/NC Single Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Is 1800/1830 RR/NC Single Hung suitable for sunbelt cooling-dominated homes?

Yes. 12 Southern-certified options inside Taylors Window and Screen, Inc. 1800/1830 RR/NC Single Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.22 SHGC on west-facing glass to avoid excess afternoon solar gain.

### How many Taylors Window and Screen, Inc. 1800/1830 RR/NC Single Hung variants earn ENERGY STAR Most Efficient?

1800/1830 RR/NC Single Hung holds zero Most Efficient entries across its 12 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

### Do 2026 1800/1830 RR/NC Single Hung installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 1800/1830 RR/NC Single Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### What permanent glass etch marks verify 1800/1830 RR/NC Single Hung after sticker removal?

Match the NFRC thermal sticker for code TWS and line TWS-K-13 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Taylors Window and Screen, Inc. 1800/1830 RR/NC Single Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
