title: "Therma-Tru Shaker Entry Door Specs (U 0.20) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/therma-tru-corporation-shaker-entry-door-414157/
description: "Therma-Tru Shaker Entry Door (THC-M-8, Swinging Entry Door (Single), Wood): U-Factor 0.20-0.28, SHGC 0.04-0.23, 434 options across 4 ENERGY STAR zones."
---

Door · Wood Frame NFRC THC · Product Line THC-M-8

# Therma-Tru Corporation — Shaker Entry Door · Swinging Entry Door (Single)

Positioning #116/268 in certified Door, Therma-Tru Corporation Shaker Entry Door pairs Wood frame with Fiberglass sash with 434 glazing options rated between 0.04 and 0.23 SHGC across Northern, North-Central, South-Central, Southern. Across 3 certified Therma-Tru Corporation product families, its thermal resistance spans 0.20 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.20

- **SHGC Range** : 0.04-0.23

- **Certified Options** : 434

- **Category Standing** : #116 of 268

## How does Therma-Tru Corporation Shaker Entry Door compare thermally against Door peers?

Therma-Tru Corporation Shaker Entry Door achieves a 0.20 thermal floor across Door lines, placing #116 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Shaker Entry Door spans 434 NFRC test records (THC), ranking #116 of 268 Door families (tied with 16 others at 0.20, more insulating than 50.7% of Door lines, top 49.3%). Its 0.20 thermal floor compares at -0.01 against the Wood median (0.21).

Mapping NFRC SHGC values (0.04 to 0.23) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 314 combinations qualify in the Northern Zone alongside 434 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 120.0 BTU/hr (-9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2025-12-08.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 434 certified glazing combinations for Shaker Entry Door (NFRC THC) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 314 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 314 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 434 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 434 packages (0 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Weather Shield Mfg., Inc.** — 8517 Contemporary Inswing Door](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8517-contemporary-inswing-door-414365/) | Wood | 0.20 | 0.13 | 503 |
| [**Andersen Corporation** — 200 Series Narroline® Gliding Patio Door](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-narroline-gliding-patio-door-412927/) | Wood | 0.20 | 0.13 | 617 |
| [**Pella Corporation** — Pella Architect Contemporary Clad Sliding Door](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-architect-contemporary-clad-sliding-door-413/) | Wood | 0.20 | 0.11 | 223 |
| [**Pella Corporation** — Pella Architect Wood Inswing Door](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-architect-wood-inswing-door-413897/) | Wood | 0.20 | 0.08 | 1,503 |
| [**Marvin** — Modern Sliding Door](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-sliding-door-413652/) | Fiberglass | 0.20 | 0.14 | 452 |

## What other certified series does Therma-Tru Corporation produce?

Compare other active Therma-Tru Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Swinging Entry Door (Single)Min U 0.15

### [Fiberglass Entry Door](https://ela-ecolandscapingassn.org/windows/models/therma-tru-corporation-fiberglass-entry-door-414156/)

U-Factor 0.15–0.28 · 1,382 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/therma-tru-corporation-fiberglass-entry-door-414156/)

Swinging Entry Door (Single)Min U 0.17

### [Classic Craft Fiberglass Entry Door](https://ela-ecolandscapingassn.org/windows/models/therma-tru-corporation-classic-craft-fiberglass-entry-door-414158/)

U-Factor 0.17–0.28 · 378 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/therma-tru-corporation-classic-craft-fiberglass-entry-door-414158/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Therma-Tru Corporation Shaker Entry Door appear below.

### What thermal performance numbers separate Therma-Tru Corporation Shaker Entry Door from peers?

EPA ENERGY STAR v7.0 records 434 configurations for Therma-Tru Corporation Shaker Entry Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.20 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

### Does Therma-Tru Corporation Shaker Entry Door qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 314 Shaker Entry Door packages (U floor 0.20, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

### How much winter heat loss does Shaker Entry Door conduct across a 15 sq ft opening?

At U 0.20, a standard 3x5 ft (15 sq ft) Shaker Entry Door opening transfers 120.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -12.0 BTU/hr difference.

### What homeowner profiles are a poor match for Therma-Tru Corporation Shaker Entry Door?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Shaker Entry Door options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### What Southern ENERGY STAR v7.0 options exist in Shaker Entry Door?

Exactly 434 Shaker Entry Door options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.04 rather than higher 0.23 glass.

### Which package tier in Shaker Entry Door holds Most Efficient recognition?

ENERGY STAR Most Efficient designation is absent across all 434 Shaker Entry Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

### What federal compliance checks govern 2026 Shaker Entry Door window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Therma-Tru Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### Where are NFRC and IGCC identification marks located on Shaker Entry Door?

Inspectors match the temporary NFRC sticker (U 0.20-0.28, SHGC 0.04-0.23) against permit drawings for line THC-M-8. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Therma-Tru Corporation Shaker Entry Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)